← Back
Two stories - detached, small or mid-size
320 EAST 18 STREET
BROOKLYN · BIN 3118490
💬 Discuss this project
1899Year Built
2.5Stories
A1Building Class
R3XZoning
2,682 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · Owner of record: 320 EAST 18 LLC · 5,000 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 24p · 1 filing · 4 docs
Floor 14p · 1 filing · 4 docs
Cellar4p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EXTREME HOMES MANAGEMENT707/08/2026
EMB DEVELOPMENT503/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/20/2024$1.6M—Private party → 320 EAST 18 LLC$578/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADB ASSOCIATES803/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGHRISE GROUP803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MOD CONSULTANTS LLCGeneral Contractor603/21/2026
P.H. WORKS INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616503/07/2025
Building Lifecycle
All (40)Filed (8)Permit Issued (3)Signed Off (3)Inspection (5)Objection (6)Special Inspection (15)
04/28/2025
Signed off — Alteration
MECHANICAL WORK TO EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING.
B01059673-I1
04/28/2025
Signed off — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-I1
04/25/2025
Signed off — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-S1
03/17/2025
Special inspection requirement — Heating Systems
FAHAD FATEH
03/17/2025
Special inspection requirement — Mechanical Systems
FAHAD FATEH
03/17/2025
Special inspection requirement — Final
FAHAD FATEH
03/07/2025
Filed — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-P3
03/07/2025
Filed — Alteration
MECHANICAL WORK TO EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING.
B01059673-P2
03/03/2025
Special inspection requirement — Final
FAHAD FATEH
03/03/2025
Special inspection requirement — Mechanical Systems
FAHAD FATEH
03/03/2025
Special inspection requirement — Heating Systems
FAHAD FATEH
02/19/2025
Filed — Alteration
MECHANICAL WORK TO EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING.
B01059673-P1
02/19/2025
Special inspection requirement — Mechanical Systems
FAHAD FATEH
02/19/2025
Special inspection requirement — Heating Systems
FAHAD FATEH
02/19/2025
Special inspection requirement — Final
FAHAD FATEH
11/22/2024
Filed — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-P2
11/22/2024
Filed — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-P1
11/22/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
11/22/2024
Special inspection requirement — Final
FAHAD FATEH
11/22/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
11/20/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
11/20/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
11/20/2024
Special inspection requirement — Final
FAHAD FATEH
09/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/29/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
08/23/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
08/13/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/31/2024
Permit issued — Mechanical Systems
B01059673-I1-MS
07/26/2024
Permit issued — Plumbing
B01045982-S1-PL
07/24/2024
Objection resolved — Addressed
07/17/2024
Objection resolved — Addressed
07/12/2024
Objection raised — Other
07/12/2024
Objection raised — Other
07/01/2024
Objection resolved — Addressed
06/26/2024
Permit issued — General Construction
B01045982-I1-GC
06/26/2024
Objection raised — Other
06/11/2024
Filed — Alteration
MECHANICAL WORK TO EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING.
B01059673-I1
05/08/2024
Filed — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-I1
05/08/2024
Filed — Alteration
PLUMBING WORK FOR EXISTING 2 STORY WITH ATTIC AND CELLAR BUILDING
B01045982-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMOD CONSULTANTS LLC07/31/2024
DOB NOWPlumbingSigned-offP.H. WORKS INC07/26/2024
DOB NOWGeneral ConstructionSigned-offMOD CONSULTANTS LLC06/26/2024
1 project · most recent 03/07/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/07/2025Signed-offP.H. WORKS INCGas, Storm, Water/Sanitary
2 projects · most recent 02/09/2026
General Wiring
FiledStatusContractorScope
02/09/2026CompleteFRIED ELECTRIC CO.General Wiring
08/19/2024CompleteLND ELECTRIC LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/29/2024Pass-Final PL - UndergroundPassView ↗
08/23/2024Pass-Final PL - UndergroundPassView ↗
08/13/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
03/17/2025Heating SystemsFAHAD FATEHspecial
03/17/2025Mechanical SystemsFAHAD FATEHspecial
03/17/2025FinalFAHAD FATEHprogress
03/03/2025FinalFAHAD FATEHprogress
03/03/2025Mechanical SystemsFAHAD FATEHspecial
03/03/2025Heating SystemsFAHAD FATEHspecial
02/19/2025Mechanical SystemsFAHAD FATEHspecial
02/19/2025Heating SystemsFAHAD FATEHspecial
02/19/2025FinalFAHAD FATEHprogress
11/22/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
11/22/2024FinalFAHAD FATEHprogress
11/22/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
11/20/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
11/20/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
11/20/2024FinalFAHAD FATEHprogress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026B01059673-I1Request digital key ↗
08/24/2026B01059673-P2Request digital key ↗
08/24/2026B01059673-P1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature5
08/28/2026B01059673-P2Open ↗
08/27/2026B01059673-P1Open ↗
08/25/2026B01045982-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/28/2026B01059673-P2Open ↗
08/27/2026B01059673-P1Open ↗
08/25/2026B01045982-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/24/2026B01059673-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026B01059673-I1Open ↗
08/24/2026B01059673-P2Open ↗
08/24/2026B01059673-P1Open ↗