Building Lifecycle
All (44)Filed (5)Objection (9)Special Inspection (30)
09/02/2026
Objection resolved — Resolved
09/02/2026
Objection resolved — Resolved
07/23/2026
Objection resolved — Resolved
05/20/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
X01366364-S4
04/14/2026
Objection raised — Other
04/14/2026
Objection raised — Other
04/14/2026
Objection raised — Scope
04/14/2026
Objection raised — Structural
04/14/2026
Objection raised — Other
04/14/2026
Objection raised — Structural
03/31/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
X01366364-S1
03/31/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
X01366364-S2
03/31/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
X01366364-S3
03/30/2026
Special inspection requirement — Structural Wood Frame
03/30/2026
Special inspection requirement — Wood – Seismic Resistance
03/30/2026
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
03/26/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
03/26/2026
Special inspection requirement — Structural Steel - Details
03/26/2026
Special inspection requirement — Structural Steel - High Strength Bolting
03/26/2026
Special inspection requirement — Final
03/26/2026
Special inspection requirement — Structural Steel - Welding
03/04/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
X01366364-I1
03/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/03/2026
Special inspection requirement — Air barrier - visual inspection
03/03/2026
Special inspection requirement — Insulation placement and R values
03/03/2026
Special inspection requirement — Fenestration areas
03/03/2026
Special inspection requirement — Interior lighting power
03/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/03/2026
Special inspection requirement — Duct leakage testing, insulation and design
03/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/03/2026
Special inspection requirement — Protection of exposed foundation insulation
03/03/2026
Special inspection requirement — Permanent certificate
03/03/2026
Special inspection requirement — Ventilation and air distribution system
03/03/2026
Special inspection requirement — Electric vehicle service equipment requirements
03/03/2026
Special inspection requirement — Metering
03/03/2026
Special inspection requirement — Energy Code Compliance Inspections
03/03/2026
Special inspection requirement — Fire-Resistance Rated Construction
03/03/2026
Special inspection requirement — Air barrier — testing
03/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/03/2026
Special inspection requirement — Fenestration air leakage
03/03/2026
Special inspection requirement — Maintenance information
03/03/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/02/2026
Special inspection requirement — Final
03/02/2026
Special inspection requirement — Mechanical Systems
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PHANTOM Z CAPITAL509/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMINOV DESIGN ENGINEER, PC505/20/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A D BUILDING SOLUTIONS203/21/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
03/30/2026Structural Wood Frame—progress
03/30/2026Wood – Seismic Resistance—special
03/30/2026Construction Utilizing CLT or SCL, Type IV—special
03/26/2026Structural Stability – Alterations of existing buildings—special
03/26/2026Structural Steel - Details—special
03/26/2026Structural Steel - High Strength Bolting—special
03/26/2026Final—progress
03/26/2026Structural Steel - Welding—special
03/03/2026HVAC-R and service water piping design and insulation—energy_progress
03/03/2026Air barrier - visual inspection—energy_progress
03/03/2026Insulation placement and R values—energy_progress
03/03/2026Fenestration areas—energy_progress
03/03/2026Interior lighting power—energy_progress
03/03/2026Fire-Resistant Penetrations and Joints—special
03/03/2026Duct leakage testing, insulation and design—energy_progress
03/03/2026HVAC-R and service water heating equipment—energy_progress
03/03/2026Protection of exposed foundation insulation—energy_progress
03/03/2026Permanent certificate—energy_progress
03/03/2026Ventilation and air distribution system—energy_progress
03/03/2026Electric vehicle service equipment requirements—energy_progress
03/03/2026Metering—energy_progress
03/03/2026Energy Code Compliance Inspections—progress
03/03/2026Fire-Resistance Rated Construction—progress
03/03/2026Air barrier — testing —energy_progress
03/03/2026HVAC-R and service water heating system controls—energy_progress
Latest 25 of 30.
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/16/2026X01366364-S1Request digital key ↗
08/16/2026X01366364-S5Request digital key ↗
08/16/2026X01366364-S4Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/16/2026X01366364-I1Open ↗
08/13/2026X01366364-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/16/2026X01366364-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/16/2026X01366364-S2Open ↗
08/16/2026X01366364-S4Open ↗
08/16/2026X01366364-S3Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/16/2026X01366364-S5Open ↗
08/16/2026X01366364-S3Open ↗
08/16/2026X01366364-S2Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports2
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/16/2026X01366364-S2Open ↗
08/16/2026X01366364-S1Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification1
08/16/2026X01366364-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026X01366364-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026X01366364-I1Open ↗