← Back
BuildNYC
Walk-up apt, over six families with stores
321 WEST 116TH STREET
MANHATTAN · BIN 1059012
💬 Discuss this project
1901Year Built
5Stories
C7Building Class
R7AZoning
10,832 sfGross Floor Area
10Units
Rent Stabilized13 Active Violations 11 unresolved · 2 paperwork only ▸
Walk-up apt, over six families with stores · Owner of record: Restoring Communities Housing Developmen T Fund Company · 2,289 sf lot · 4.73 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofRestoring Communities HDFC40p · 3 filings · 20 docs
Floor 5Restoring Communities HDFC34p · 3 filings · 20 docs
Floor 4Restoring Communities HDFC36p · 3 filings · 20 docs
Floor 3Restoring Communities HDFC33p · 3 filings · 20 docs
Floor 2Restoring Communities HDFC33p · 3 filings · 20 docs
Floor 1Restoring Communities HDFC41p · 4 filings · 20 docs
CellarRestoring Communities HDFC37p · 3 filings · 20 docs
Site & exteriorRestoring Communities HDFC19p · 3 filings · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC Department of Housing Preservation and Development3507/08/2026
Restoring Communities HDFC1503/22/2026
City103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Gilsanz Murray Steficek401/12/2026
Emtg Consultants909/10/2025
Rigid Structural Design112/12/2024
Wellworth Consulting410/03/2024
Mje Professional Services111/01/2023
Haider Engineering, P.E112/07/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
United Safety Consultants303/21/2026
Preemptive Solutions & Consulting203/21/2026
JM Zoning803/21/2026
Rigid Structural Design203/21/2026
Design 21471003/21/2026
Haider Engineering, P.E103/21/2026
Haider Engineering P E103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Aura PlumbingPlumbing1507/08/2026
Summit JVGeneral Contractor904/09/2026
Spring ScaffoldingScaffold807/08/2026
Mark Contracting NYScaffold507/08/2026
Reliable EnterprisesScaffold407/08/2026
Brightlights Electrical SerElectrical203/21/2026
Aura PlumbingFire Protection207/08/2026
4 Brothers & Sons FenceScaffold203/21/2026
Robert J. Sankey P&HPlumbing103/22/2026
Duro Electrical ContngElectrical103/22/2026
P & M Elect'l ContractingElectrical103/21/2026
Build NexusElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Kce Consulting Engineering37121201/12/2026
Gilsanz Murray Steficek240207/17/2023
Building Lifecycle
All (145)Filed (20)Permit Issued (19)Signed Off (6)Violation (60)Inspection (4)Objection (6)Special Inspection (30)
05/19/2026
Signed off — Alteration
M01142244-I1
05/12/2026
Signed off — Alteration
HEREWITH FILING STRUCTURAL WORK AS PER PLANS IN CONJUNCTION WITH ALT1 APPLICATION_140926327
M00367903-I1
04/29/2026
Violation issued (HPD, open)
A
01/26/2026
Special inspection requirement — Subgrade Inspections
Kemba Walcott
01/26/2026
Special inspection requirement — Masonry
Kemba Walcott
01/26/2026
Special inspection requirement — Structural Steel - Welding
Kemba Walcott
01/26/2026
Special inspection requirement — Sprayed fire-resistant materials
Kemba Walcott
01/26/2026
Special inspection requirement — Structural Steel - High Strength Bolting
Kemba Walcott
01/26/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kemba Walcott
01/26/2026
Special inspection requirement — Structural Steel - Details
Kemba Walcott
01/26/2026
Special inspection requirement — Final
Kemba Walcott
01/14/2026
Signed off — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLAN IN CONJUNCTION WITH ALT1 APPLICATION_
M00363215-I1
01/12/2026
Filed — Alteration
HEREWITH FILING STRUCTURAL WORK AS PER PLANS IN CONJUNCTION WITH ALT1 APPLICATION_140926327
M00367903-P4
11/18/2025
Special inspection requirement — Masonry
Kemba Walcott
11/18/2025
Special inspection requirement — Final
Kemba Walcott
11/18/2025
Special inspection requirement — Subgrade Inspections
Kemba Walcott
11/18/2025
Special inspection requirement — Structural Steel - Welding
Kemba Walcott
11/18/2025
Special inspection requirement — Structural Steel - High Strength Bolting
Kemba Walcott
11/18/2025
Special inspection requirement — Structural Steel - Details
Kemba Walcott
11/18/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kemba Walcott
11/18/2025
Special inspection requirement — Sprayed fire-resistant materials
Kemba Walcott
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/03/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/30/2025
Special inspection requirement — Standpipe Systems
09/30/2025
Special inspection requirement — Sprinkler Systems
Kemba Walcott
09/25/2025
Special inspection requirement — Mechanical Systems
Kemba Walcott
09/25/2025
Special inspection requirement — Final
Kemba Walcott
09/25/2025
Special inspection requirement — HVAC insulation and sealing
Kemba Walcott
09/25/2025
Special inspection requirement — HVAC and service water heating equipment
Kemba Walcott
09/25/2025
Special inspection requirement — HVAC and service water heating system controls
Kemba Walcott
09/25/2025
Special inspection requirement — Maintenance information
Kemba Walcott
09/25/2025
Special inspection requirement — Electrical motors
Kemba Walcott
09/23/2025
Objection resolved — Addressed
09/16/2025
Objection raised — Scope
09/10/2025
Filed — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLAN IN CONJUNCTION WITH ALT1 APPLICATION_
M00363215-P3
09/10/2025
Filed — Alteration
HEREWITH FILING PLUMBING, SPRINKLER, & STANDPIPE WORK AS PER PLANS IN CONJUNCTION WITH ALT1 APPLICATION_
M00363213-P4
09/02/2025
Special inspection requirement — Electrical motors
Kemba Walcott
09/02/2025
Special inspection requirement — Maintenance information
Kemba Walcott
09/02/2025
Special inspection requirement — HVAC insulation and sealing
Kemba Walcott
09/02/2025
Special inspection requirement — HVAC and service water heating equipment
Kemba Walcott
09/02/2025
Special inspection requirement — HVAC and service water heating system controls
Kemba Walcott
08/12/2025
Signed off — Alteration
M00956035-I1
06/04/2025
Violation issued (HPD, open)
A
05/28/2025
Permit issued — Mechanical Systems
M00363215-I1-MS
05/28/2025
Permit issued — Structural
M00367903-I1-ST
05/01/2025
Filed — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLAN IN CONJUNCTION WITH ALT1 APPLICATION_
M00363215-P2
04/09/2025
Permit issued — Standpipe
M00363213-I1-PL
04/09/2025
Permit issued — Plumbing
M00363213-I1-EW-SP
04/04/2025
Permit issued — Mechanical Systems
M00363215-I1-MS
03/04/2025
Filed — Alteration
HEREWITH FILING PLUMBING, SPRINKLER, & STANDPIPE WORK AS PER PLANS IN CONJUNCTION WITH ALT1 APPLICATION_
M00363213-P3
12/13/2024
Permit issued — Construction Fence
M01142244-I1-FN
12/12/2024
Filed — Alteration
M01142244-I1
12/12/2024
Signed off — Alteration
Installation of supported pipe scaffolding as indicated on the attched drawings. There are no changes in use, egress or occupancy.
M00814968-I1
11/22/2024
Violation issued (HPD, closed)
I
11/13/2024
Signed off — Alteration
Installation of supported pipe scaffolding as indicated on the attched drawings. There are no changes in use, egress or occupancy.
M00814968-S1
10/17/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/03/2024
Filed — Alteration
Installation of supported pipe scaffolding as indicated on the attched drawings. There are no changes in use, egress or occupancy.
M00814968-P2
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/27/2024
Permit issued — Supported Scaffold
M00814968-S1-SF
06/03/2024
Permit issued — Structural
M00367903-I1-ST
Latest 60 of 145 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offSummit JV05/28/2025
DOB NOWStructuralPermit IssuedSummit JV05/28/2025
DOB NOWPlumbingPermit IssuedAura Plumbing04/09/2025
DOB NOWSprinklersSigned-offAura Plumbing04/09/2025
DOB NOWMechanical SystemsSigned-offSummit JV04/04/2025
DOB NOWConstruction FenceSigned-off4 Brothers Sons Fence12/13/2024
DOB NOWSupported ScaffoldSigned-offSpring Scaffolding06/27/2024
DOB NOWStructuralPermit IssuedSummit JV06/03/2024
DOB NOWPlumbingPermit IssuedAura Plumbing01/26/2024
DOB NOWSprinklersSigned-offAura Plumbing01/25/2024
DOB NOWSidewalk ShedSigned-offSpring Scaffolding01/25/2024
DOB NOWSupported ScaffoldSigned-offReliable Enterprises12/12/2023
DOB NOWSupported ScaffoldSigned-offReliable Enterprises11/01/2023
DOB NOWSupported ScaffoldSigned-offSpring Scaffolding06/28/2023
DOB NOWStructuralPermit IssuedSummit JV06/07/2023
DOB NOWSidewalk ShedSigned-offSpring Scaffolding01/25/2023
DOB NOWSidewalk ShedPermit IssuedMark Contracting NY03/12/2020
DOB NOWSidewalk ShedPermit IssuedMark Contracting NY03/08/2019
DOB NOWSidewalk ShedPermit IssuedMark Contracting NY12/10/2018
BIS—ISSUEDSummit JV03/31/2025
BIS—ISSUEDSummit JV05/31/2024
BIS—ISSUEDSummit JV04/02/2024
BIS—ISSUEDSummit JV05/26/2023
BIS—ISSUEDSummit JV02/01/2023
BIS—ISSUEDSummit JV12/13/2022
BISEQISSUEDLakhi General Contractor03/18/2016
BISEQISSUEDKing Raja Construction11/20/2001
BISOTISSUEDKing Raja Construction11/20/2001
BISOTISSUEDTirath Construction Co08/06/1998
BISPLISSUEDQueens Maintenence Co09/11/1995
BISPLISSUEDQueens Maintenence Co09/11/1995
BISPLISSUEDControl Plumbing & Heating09/22/1994
BISBLISSUEDControl Plumbing & Heating09/22/1994
BISOTISSUEDNY Friendly Construction Co06/17/1994
1 project · most recent 09/10/2025
FiledStatusContractorScope
09/10/2025Signed-offAura Plumbing292 heads, 45 outlets
1 project · most recent 09/10/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/10/2025Permit IssuedAura PlumbingGas, Storm, Water/Sanitary
4 projects · most recent 11/10/2025
General Wiring
FiledStatusContractorScope
11/10/2025Permit IssuedDuro Electrical ContngGeneral Wiring
01/25/2023CompleteTop Shelf Electric—
12/19/2018Permit IssuedRichard Neu—
12/22/2017Permit IssuedDeltex Electrical Cont. IGeneral Wiring
1 project · most recent 01/12/2026
Steel Concrete Masonry Wood
FiledStatusContractorScope
01/12/2026Permit IssuedSummit JVSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/03/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/17/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
04/02/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/02/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
01/26/2026Subgrade InspectionsKemba Walcottspecial
01/26/2026MasonryKemba Walcottspecial
01/26/2026Structural Steel - WeldingKemba Walcottspecial
01/26/2026Sprayed fire-resistant materialsKemba Walcottspecial
01/26/2026Structural Steel - High Strength BoltingKemba Walcottspecial
01/26/2026Structural Stability – Alterations of existing buildingsKemba Walcottspecial
01/26/2026Structural Steel - DetailsKemba Walcottspecial
01/26/2026FinalKemba Walcottprogress
11/18/2025MasonryKemba Walcottspecial
11/18/2025FinalKemba Walcottprogress
11/18/2025Subgrade InspectionsKemba Walcottspecial
11/18/2025Structural Steel - WeldingKemba Walcottspecial
11/18/2025Structural Steel - High Strength BoltingKemba Walcottspecial
11/18/2025Structural Steel - DetailsKemba Walcottspecial
11/18/2025Structural Stability – Alterations of existing buildingsKemba Walcottspecial
11/18/2025Sprayed fire-resistant materialsKemba Walcottspecial
09/30/2025Standpipe Systems—special
09/30/2025Sprinkler SystemsKemba Walcottspecial
09/25/2025Mechanical SystemsKemba Walcottspecial
09/25/2025FinalKemba Walcottprogress
09/25/2025HVAC insulation and sealing Kemba Walcottenergy_progress
09/25/2025HVAC and service water heating equipment Kemba Walcottenergy_progress
09/25/2025HVAC and service water heating system controls Kemba Walcottenergy_progress
09/25/2025Maintenance informationKemba Walcottenergy_progress
09/25/2025Electrical motorsKemba Walcottenergy_progress
Latest 25 of 45.
▾Documents — 255 on file (BIS + DOB NOW)
▸Plans & Drawings30
▸DOB NOWPlans/Sketch7
09/06/2026M00106303-I1Request digital key ↗
08/28/2026M00956035-I1Request digital key ↗
08/26/2026M00814968-S1Request digital key ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler5
08/27/2026M00363213-P4Request digital key ↗
08/27/2026M00363213-P3Request digital key ↗
08/27/2026M00363213-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Standpipe5
08/27/2026M00363213-P2Request digital key ↗
08/27/2026M00363213-P4Request digital key ↗
08/27/2026M00363213-P3Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Plumbing5
08/27/2026M00363213-P4Request digital key ↗
08/27/2026M00363213-P3Request digital key ↗
08/27/2026M00363213-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Structural4
08/31/2026M00367903-I1Request digital key ↗
08/31/2026M00367903-P2Request digital key ↗
08/31/2026M00367903-P4Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems4
08/28/2026M00363215-I1Request digital key ↗
08/28/2026M00363215-P2Request digital key ↗
08/15/2026M00363215-P3Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits32
▸BISPLAN / WORK APPROVAL APPLICATION25
03/02/2026100894338Open ↗
08/21/2025140964507Open ↗
08/20/2025140926327Open ↗
Showing 3 of 25 on file for this type
▸BISWORK PERMIT APPLICATION5
04/01/2025140926327Open ↗
04/02/2024140926327Open ↗
02/02/2023140926327Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
09/24/2025140926327Open ↗
04/03/2025140926327Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISVERIFY TAX LOT1
01/15/2026140926327Open ↗
▸Seals & Professional Certifications57
▸DOB NOWDPL-1: Design Professional Seal & Signature20
09/06/2026M00106303-I1Open ↗
08/31/2026M00367903-I1Open ↗
08/31/2026M00367903-P1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/01/2026M00363215-I1Open ↗
09/01/2026M00363215-I1Open ↗
09/01/2026M00363215-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/01/2026M00363215-I1Open ↗
08/31/2026M00367903-I1Open ↗
08/31/2026M00367903-I1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM6
03/14/2012121002761Open ↗
03/14/2012121002761Open ↗
03/14/2012121002761Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
03/29/2016122544381Open ↗
03/12/2012121002654Open ↗
03/12/2012121002761Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
03/12/2012121002761Open ↗
03/12/2012121002654Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/29/2016122544381Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/19/2021140964507Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/19/2021140964507Open ↗
▸Trade Schedules & Equipment10
▸BISSPRINKLER INSP REPORT : FP-855
03/12/2012121002654Open ↗
03/12/2012121002654Open ↗
03/12/2012121002654Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
03/14/2012121002761Open ↗
03/14/2012121002761Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
10/17/2025140926327Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
05/21/2025140926327Open ↗
▸BISSCHEDULE B - PLUMBING1
03/14/2012121002654Open ↗
▸Safety & Tenant Protection15
▸DOB NOWTenant Protection Plan13
08/28/2026M00363215-I1Open ↗
08/28/2026M00363215-P2Open ↗
08/27/2026M00363213-P3Open ↗
Showing 3 of 13 on file for this type
▸BISSTREET TREE CHECKLIST1
12/13/2022140926327Open ↗
▸BISBPP: STREET TREES SITE PLAN1
07/19/2021140964507Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/31/2026M00367903-P4Open ↗
08/31/2026M00367903-I1Open ↗
08/31/2026M00367903-P1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS-CERTIFICATION (DEP ACP5)3
03/14/2012121002761Open ↗
03/14/2012121002654Open ↗
12/13/2022140926327Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/13/2026M00363215-I1Open ↗
08/13/2026M00363213-I1Open ↗
▸BISONE (1) ACP21 FOR ATRU2825MN22 IS REQUIRED PRIOR TO SIGNOFF. WMS 12 JAN 20231
04/03/2025140926327Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
10/07/2025140964507Open ↗
▸Energy Compliance16
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/13/2022140926327Open ↗
12/03/2020140926327Open ↗
▸BISFENESTRATION AREAS1
06/03/2025140926327Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
06/03/2025140926327Open ↗
▸BISLIGHTING IN DWELLING UNITS1
06/03/2025140926327Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
06/03/2025140926327Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/19/2025140926327Open ↗
▸BISLIGHTING CONTROLS1
06/03/2025140926327Open ↗
▸BISTECHNICAL REPORT: ENERGY1
12/05/2011120914243Open ↗
▸BISEXTERIOR LIGHTING POWER1
10/17/2025140926327Open ↗
▸BISFENESTRATION AIR LEAKAGE1
06/03/2025140926327Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
10/17/2025140926327Open ↗
▸BISINTERIOR LIGHTING POWER1
06/03/2025140926327Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
10/17/2025140926327Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
10/17/2025140926327Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00363215-I1Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY3
12/13/2022140926327Open ↗
07/19/2021140964507Open ↗
12/03/2020140926327Open ↗
▸BISMASONRY1
06/03/2025140926327Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
06/03/2025140926327Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
06/03/2025140926327Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
06/03/2025140926327Open ↗
▸Approvals, Objections & Sign-offs51
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter15
09/06/2026M00106303-I1Open ↗
08/28/2026M00363215-P2Open ↗
08/28/2026M00363215-I1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)13
08/28/2026M00363215-I1Open ↗
08/28/2026M00363215-P2Open ↗
08/27/2026M00363213-P3Open ↗
Showing 3 of 13 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION11
08/22/2025140964507Open ↗
08/20/2024140926327Open ↗
04/02/2024140926327Open ↗
Showing 3 of 11 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE7
07/17/2025140926327Open ↗
07/15/2025140926327Open ↗
03/26/2025140926327Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
03/14/2012121002654Open ↗
03/14/2012121002761Open ↗
12/12/2011120914243Open ↗
▸BISDESIGN COMM. APPROVAL: CITY-OWNED PROPERTY (EXTERIOR WORK)1
08/18/2021140926327Open ↗
▸BISSUPERSEDING LETTER1
04/01/2025140926327Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
07/19/2021140964507Open ↗
03/14/2012121002654Open ↗
03/14/2012121002761Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms16
▸BISADDITIONAL INFORMATION11
10/07/2025140964507Open ↗
08/26/2025140926327Open ↗
08/22/2025140964507Open ↗
Showing 3 of 11 on file for this type
▸BISEFILING COVER SHEET4
03/29/2016122544381Open ↗
03/12/2012121002761Open ↗
03/12/2012121002654Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
07/19/2021140964507Open ↗
▸Other Documents5
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
03/29/2016122544381Open ↗
▸BISVESTIBULES1
10/17/2025140926327Open ↗
▸BISPLOT DIAGRAM1
12/05/2011120914243Open ↗
▸BISSHUTOFF DAMPERS1
10/17/2025140926327Open ↗
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
08/13/2026M00106303-I1Open ↗