| Owner | Filings | Most Recent |
|---|---|---|
| 19 BARBEY | 16 | 07/04/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 03/25/2025 | $190K | — | — → — | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| D&E BUILD EVERGREEN INC. | 6 | 06/30/2026 |
| PETER CHO ARCHITECTS, PLLC | 1 | 05/28/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| METRO DESIGN CONSULTANTS INC | 10 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| RISHON HOMES CORP | General Contractor | 4 | 07/04/2026 |
| INFINITI ESC PLUMBING COR | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| D&E BUILD EVERGREEN I | 9342 | 5 | 06/30/2026 |
| TRIANGLE INSPECTION & TES | 7495 | 2 | 03/09/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Curb Cut | Signed-off | RISHON HOMES CORP | 05/26/2026 |
| DOB NOW | Plumbing | Signed-off | INFINITI ESC PLUMBING COR | 09/08/2025 |
| DOB NOW | Structural | Permit Issued | RISHON HOMES CORP | 08/12/2025 |
| DOB NOW | General Construction | Signed-off | RISHON HOMES CORP | 08/11/2025 |
| DOB NOW | Construction Fence | Signed-off | RISHON HOMES CORP | 08/08/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/30/2026 | Signed-off | RISHON HOMES CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Gree GMV-V60WL/C-T(U) 60,000 BTU · Vrf Outdoor ×2 LIV18HP230V1R32AO 18,000 BTU · Condensing Unit ×2 MUL36HP230V1R32AO 36,000 BTU · Condensing Unit ×2 Ventilation Hampton Bay 7114-01 50 CFM · Exhaust Fan ×8 Delta Breeze SMT150 150 CFM · Exhaust Fan ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/30/2026 | Signed-off | INFINITI ESC PLUMBING COR | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/26/2025 | Complete | POWER SURGE ELECTRIC, INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/30/2026 | Signed-off | RISHON HOMES CORP | Steel, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/30/2026 | Signed-off | RISHON HOMES CORP | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/30/2026 | Signed-off | RISHON HOMES CORP | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/27/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/01/2026 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 06/30/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/17/2026 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 04/24/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 04/24/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 12/04/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/04/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 09/15/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 09/15/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 09/15/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/15/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/01/2026 | Mechanical Systems | Danny Chen | special |
| 07/01/2026 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | Danny Chen | special |
| 07/01/2026 | Structural Cold-Formed Steel | Danny Chen | special |
| 07/01/2026 | Structural Steel - Details | Danny Chen | special |
| 07/01/2026 | Excavations - Sheeting, Shoring, and Bracing | Danny Chen | special |
| 07/01/2026 | Masonry | Danny Chen | special |
| 07/01/2026 | Concrete - Cast-In-Place | Danny Chen | special |
| 07/01/2026 | Fire-Resistant Penetrations and Joints | Danny Chen | special |
| 07/01/2026 | Heating Systems | Danny Chen | special |
| 07/01/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Danny Chen | special |
| 07/01/2026 | Structural Steel - High Strength Bolting | Danny Chen | special |
| 07/01/2026 | Subgrade Inspections | Danny Chen | special |
| 07/01/2026 | Subsurface Investigations (Borings/Test Pits) | Rajasekhar Sakhamuri | special |
| 07/01/2026 | Fire-Resistance Rated Construction | Danny Chen | progress |
| 07/01/2026 | Energy Code Compliance Inspections | Danny Chen | progress |
| 07/01/2026 | Final | PETER CHO | progress |
| 07/01/2026 | Footing and Foundation | Danny Chen | progress |
| 07/01/2026 | Structural Wood Frame | Danny Chen | progress |
| 07/01/2026 | Lowest Floor Elevation | Danny Chen | progress |
| 07/01/2026 | HVAC-R and service water piping design and insulation | Danny Chen | energy_progress |
| 07/01/2026 | Maintenance information | Danny Chen | energy_progress |
| 07/01/2026 | Duct leakage testing, insulation and design | Danny Chen | energy_progress |
| 07/01/2026 | Fenestration air leakage | Danny Chen | energy_progress |
| 07/01/2026 | HVAC-R and service water heating equipment | Danny Chen | energy_progress |
| 07/01/2026 | Electric vehicle service equipment requirements | Danny Chen | energy_progress |