← Back
Two family converted from one family
3226 CORSA AVENUE
BRONX · Eastchester-Edenwald-Baychester · BIN 2061214
💬 Discuss this project
1950Year Built
2Stories
B3Building Class
R4Zoning
1,260 sfGross Floor Area
2Units
0 Open Violations
Two family converted from one family · 1,800 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNER OF 3226 CORSA AVE103/22/2026
EAST 229 CORP.103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/22/2023$725K—— → —$575/sf building
11/01/2021$425K—Private party → EAST 229 CORP$337/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC101/05/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Streekout Solutions103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SURF CLEAN ENERGY INCGeneral Contractor303/21/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854101/05/2024
Building Lifecycle
All (16)Filed (1)Permit Issued (1)Violation (1)Objection (8)Special Inspection (5)
01/31/2024
Permit issued — Solar
X00986529-I1-SL
01/24/2024
Objection resolved — Addressed
01/24/2024
Objection resolved — Addressed
01/23/2024
Objection resolved — Addressed
01/23/2024
Objection resolved — Addressed
01/11/2024
Objection raised — Other
01/11/2024
Objection raised — Zoning
01/11/2024
Objection raised — Other
01/11/2024
Objection raised — Other
01/05/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00986529-I1
01/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
01/05/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
01/05/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
01/05/2024
Special inspection requirement — Final
TOM PETERSEN
01/05/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
10/19/2000
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSURF CLEAN ENERGY INC01/31/2024
3 projects · most recent 06/21/2024
FiledStatusContractorScope
06/21/2024CompleteAMPACITY ELECTRICAL INC—
01/17/2024Permit IssuedBERGER QUALITY ELEC'L CON—
03/09/2022CompletePOWER SURGE ELECTRIC, INC2 meters, 1 new_meters
1 project · most recent 01/05/2024
FiledStatusContractorScope
01/05/2024Permit IssuedSURF CLEAN ENERGY INC7 panels, 2.84 kw, 536 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/05/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
01/05/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
01/05/2024Energy Code Compliance InspectionsTOM PETERSENprogress
01/05/2024FinalTOM PETERSENprogress
01/05/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026X00986529-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026X00986529-I1Open ↗
08/27/2026X00986529-I1Open ↗
08/27/2026X00986529-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026X00986529-I1Open ↗
08/27/2026X00986529-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X00986529-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X00986529-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X00986529-I1Open ↗