DOB02/10/2026FAILURE TO MAINTAIN - ORIGINAL BUILDING FULLY DEMOLISHED. NEW 2 STORY BUILDING PARTIALLY ERECTED. RECOMMEND WEEKLY STRUCTURAL INSPECTIONS REMEDY: RETAIN PE TO PERFORM STABILITY INSPECTIONS AT LEAST ONCE PER WEEK. REPORTS TO BE READILY AVAILABLE UPON REQUEST
DOB02/10/2026FAILURE TO MAINTAIN - ORIGINAL BUILDING FULLY DEMOLISHED. NEW 2 STORY BUILDING PARTIALLY ERECTED. WORK DOES NOT CONFORM WITH APPROVED DOCUMENTS. REMEDY: RETAIN PE & GC TO TEMP STABILIZE BLDG TO SAFEGUARD SITE, ADJ PROP, PUBLIC. COMMENCE UNDER PERMIT BY 3/16/2026
ECB01/08/2026FAILURE TO SAFEGUARD THE PUBLIC AFFECTED BY CONSTRUCTION OPERATIONS. ATOI NO CONSTRUCTION FENCE AT EXPO 1 FOR ACTIVE JOB # B01221138., MAINTAIN ADEQUATE CONSTRUCTION HOUSEKEEPING$2K due
ECB01/08/2026FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION UNDER JOB # B01221138 . NO GUARD RAILS. ATOI OBSERVED NO GUARDRAIL SYSTEM LEADING FROM 1ST FLOOR TO BASEMENT. STAIRS WERE TORN D$5K due
ECB01/08/2026UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT UNDER ACTIVE PERMIT # B01221138 ATOI OBSERVED 3 ACETYLENE TANKS FREE STANDING AT EXPO 1,1ST FLOOR., MAINTAIN STORAGE IN COMPLIANCE WITH FIRE CODE$2K due
ECB01/08/2026FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS UNDER ACTIVE JOB # B01221138 . ATOI OBSERVED DEBRIS THROUGHOUT ENTIRE FIRST FLOOR, BACKYARD AND EXPO 1 LEADING INTO PROPERTY. SHINGLES, WOOD,ST$2K due
ECB01/08/2026FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS UNDER ACTIVE JOB # B01221138 ATOI OBSERVED DEBRIS FALLING ONTO ADJACENT PROPERTY 321 38TH ST OBSERVED DEBRIS ON AWNING ALONG THEI$5K due
ECB01/08/2026ATOI OBSERVED 100% OF 2 STORY HOME DEMOED. ALL EXTERIOR WALLS HAVE BEEN REMOVED WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS. ACTIVE PERMIT #B01221138 ,WHICH INDICATE EXTERIOR WALLS TO REMAIN., CONF$2K due
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING KITCHEN BASEMENT APT. REAR # 2. ER - 1.
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING KITCHEN BASEMENT APT. REAR # 2.
HPD03/24/2004SECTION 9, 56, 193, 300, 302 M.D. LAW- ABOVE FRAME BUILDING HAS BEEN CONVERTED FROM A PRIVATE DWELLING TO A MULTIPLE DWELLING AND IS NOW OCCUPIED AND MAINTAINED AS SUCH CONTRARY TO LAW.RESTORE PREMISES TO LAWFUL OCCUPANCY
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING CENTER ROOM 1ST. STY. REAR APT.
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALLS AND FLOOR BATHROOM BASEMENT APT. REAR # 2.
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF CONCEALED WATER LEAK CEILING, KITCHEN, 1ST. STY. REAR APT.
HPD03/24/2004SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES 1ST. STY. REAR APT.
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS REAR ROOM 1ST. STY. REAR APT.
HPD03/24/2004SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALLISTERS BALUSTRADE 1ST TO 2ND STY.
HPD03/24/2004SECTION 27-2026 ADMIN. CODE: REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION BATHROOM CENTER ROOM 1ST. STY. PUBLIC HALL.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTERBOARD CEILING CELLAR.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF CELOTEX DROP CEILING CENTER ROOM BASEMENT REAR APT. # 2.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING KITCHEN 1ST. STY REAR APT. ER - 1.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURES FRONT ENTRANCE TO BUILDING.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC WALL TILE BATHROOM 1 STY. PUBLIC HALL.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES FRONT ENTRANCE TO BUILDING.
HPD07/23/2003SECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES 1ST AND 2ND STORIES PUBLIC HALL.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING KITCHEN BASEMENT APT. REAR FROM EXTENSION ROOF REAR BUILDING.
HPD07/23/2003SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING CELLAR CENTER.
ECB01/02/2026ATOI AS PER DOB FILE ACTIVE PERMIT B01221138-I1-GC WAS ISSUED ON 07/25/2025 BUT ITS NOT POSTED ON SITE, POST/PROPERLY POST PERMITNothing owed — awaiting certificate of correction