ECB06/15/2026UPON INSPECTION I OBSERVED PEDESTRIAN PROTECTION (JERSEY BARRIERS) INSTALLED AT EXPOS 1&4 CONTRARY TO CODE 3307.2. PROVIDED JERSEY BARRIERS WERE NOT FILLED WITH WATER OR SAND AND NOT SECURED TOGETHER TO PREVENT$2K due
ECB05/21/2026OBSERVED INADEQUATE CONSTRUCTION FENCE @ PERIMETER OF JOBSITE. CONSTRUCTION HAS ADVERTISEMENTS PLASTERED ALONG THE PERIMETER, CONSTRUCTION FENCE WOOD PANEL CHIPPED ON TOP, AND DISLODGED WITH GAPS BETWEEN PANELS$1K due
ECB04/09/2026B.C 3307.4 OBSERVED A CONSTRUCTION FENCE INSTALLED FULLY BLOCKING OFF THE SIDEWALK WHICH FORCES PEDESTRIANS TO HAVE TO USE THE TEMPORARY WALKWAY WHICH WAS SETUP WITH JERSEY BARRIERS ON THE STREET. DOT PERMITS S$2K due
ECB02/01/2026OBSERVED CLOSED 3STORY NB. PEDESTRIAN WALKWAYS BEING USED @EXPOS1&4 NOT UP TO CODE. PEDESTRIAN WALKWAY IS NOT MINIMUM OF 5FT AS REQUIRED BY DOT STIPULATIONS, UNCLEARED SNOW IS HAZARDOUS,YODOCKS NOT CONNECTED TO$625 due
ECB02/01/2026OBSERVED PROPOSED 3STORY NB WITH PUMP-JACK SCAFFOLDS INSTALLED W/OUT ACTIVE PERMIT. PUMP-JACK SCAFFOLDS ARE INSTALLED @EXPOS1&4 AND SURPASSING THE HEIGHT OF THE BUILDING, POSTS OF PUMPJACK HIGHER THAN 40FT. UPO$1K due
ECB02/01/2026JOBSITE FENCE NOT MAINTAINED AS PER 3307.7. FENCE @EXPO1 DISLODGING ONTO PEDESTRIAN WALKWAY,AT RISK OF FALLING ON PUBLIC.PUT PUBLIC AT RISK OF TRIPPING,FALLING,RUNNING INTO FENCE. @EXPO1&4 EXCESSIVE ADS POSTED$2K due
ECB02/01/2026OBS MAKESHIFT GUARDRAILS @ CORNER OF EXPO1&2 ON FLOORS 2&3 ARE DISLODGED, NO DEBRIS NETTING, NOT AS PER 3308.7.3. CONDITIONS UNSAFE TO PUBLIC, PROPERTY, AND WORKERS. DOB ISSUED WINTER WEATHER ADVISOR;: EXPECTED$5K due
ECB12/08/2025OBSERVED ACTIVE SITE UPON REQUEST FAILED TO PROVIDE SITE SAFETY PLANS, NO STRUCTURAL DESIGN DRAWINGS, NO MANUFACTURER SPECIFICATIONS FOR COLD FORM STEEL/ C-JOIST WORK @ LEVEL 1. ALL APPROVE DOCUMENTS MUST BE MA$1K due
ECB12/08/2025OBSERVED ACTIVE SITE WITH MUTIPLE UNSAFE CONDITIONS 3301.5 WORKERS ON SECOND LEVEL FULLY TIE-OFF WITHOUT ANY PROPER INGRESS/ EGRESS, NO THREE POINTS OF CONTRACT WITH FULLY EXTENDED CONSTRUCTION LATTER. ACTIVE W$2K due
ECB12/06/2025AT THE TIME OF INSPECTION, INACTIVE JOBSITE. I OBSERVED THAT THE CONSTRUCTION FENCE PANELS AT EXPOSURE ALL EXPOSURE NOT PROPERLY MAINTAINED PURSUANT TO SUBSECTION ACCORDING TO BC 3307.7. FENCE PANELS IN INADEQ$1K due
ECB12/06/2025OBSERVED JERSEY BARRIERS IN USE OF A PEDESTRIAN WALK WAY WITH A SPACE OF 2 FT 5" . MOST AREAS AROUND THE SITE ONLY HAD A 4 FOOT CLEARANCE. PEOPLE HAD TO TAKE TURNS PASSING. THIS CREATES A SAFETY HAZARD FOR PEDE$2K due
ECB11/18/2025IVAN BOSTON STATED TO BE THE DESIGNATED COMPETENT PERSON, UPON VERIFICATION SST CARD, CARD WITH MULTIPLE EXPIRED REQUIRED/ MANDATORY CLASSES. CONSTRUCTION SUPERINTENDENT NOT PRESENT, ALTERNATE CS NOR ALTERNATE$5K due
ECB11/18/2025CONSTRUCTION SUPERINTENDENT FAILED TO ENSURE THAT COMPETENT PERSON ON DAILY LOG BOOK FOR 11-18-2025 HAD VALID SST CARD, JOBSITE @ SOE/ EXCAVATION PHASE W/OUT PLANS, SOE, DAMAGES TO ADJACENT PROPERTIES, AND PEDE$5K due
ECB04/09/2026OBSERVED JERSEY BARRIERS ON THE STREET INSTALLED AS A PEDESTRIAN WALKWAY DUE TO THE CONSTRUCTION FENCE FULLY BLOCKING OFF THE SIDEWALK. BARRIERS ARE NOT MAINTAINED AS PER SPECIFICATIONS. MISSING INTERLOCKING COHearing held — result not yet published$1K proposed