ECB03/19/2026FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS NUMBER 35683156J, FILE A CERTIFICATE OF CORRECTION$6K due
ECB03/19/2026FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS NUMBER 35683159P, FILE A CERTIFICATE OF CORRECTION$6K due
ECB03/19/2026FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS NUMBER 35683158N, FILE A CERTIFICATE OF CORRECTION$6K due
ECB03/19/2026PARAPET REPAIRED, APPROVED JOB X01229312 FOR REPAIR WORK - HOWEVER PERMITS NOT ISSUED, OBTAIN ALL PERMITS$6K due
DOB06/13/2025CORRECTION ACTION PLAN REQ'D.OBSV @ EXP2 @ EXP3 AN EXPANDING MASONRY CRACK APPROX 1/2 WIDE @ PARAPET LEVEL.ALSO OBSVA CRACK GLASS WINDOW ON THE 5FL OF EXP3 COURTYARD.OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL ENTIRE BLDG& TO SUBMIT CORRECTIVE ACTION PLAN WITHIN 30 DAYS
ECB04/25/2025WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, A C HOOK SUSPENDED SCAFFOLD HAD BEEN INSTALLED AT THE STRUCTURALLY COMPROMISED PARAPET AT EXPOSURE 1/2 CORNER, AND A CONSTRUCTION WORKER WAS PERFORMINH CONSTRUCTION$2K due
ECB04/18/2025FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. I OBSERVED HAZARDOUS CONDITION WITH AN APPROX. EIGHT-FOOT VERTICAL CRACK ALONG EXTERIOR WALL AND THE PARAPET WALL OF EXPOSURE TWO AND THREE, BOTH CRACKS$2K due
ECB04/18/2025FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. A PROACTIVE INSPECTION WAS CONDUCTED AT 324 POWERS AVENUE,BRONX ON APRIL 17, 2025. THE PI OBSERVED A SIGNIFICANT VERTICAL CRACK$10K due
ECB04/18/2025FAILED TO NOTIFY DEPARTMENT OF BUILDINGS PRIOR TO INSTALLATION OR REMOVAL OF SUSPENDED SCAFFOLD. NOTE: AT TIME OF INSPECTION, A C HOOK SUSPENDED SCAFFOLD HAS BEEN INSTALLED AT THE STRUCTURALLY COMPROMISED PARAP$2K due
DOB04/18/2025REMEDY: EXPO 1 APPROX 120 LF OF SIDEWALK SHED SHALL BE ERECTED ALONG T HE FULL WIDTH OF THE FACADE, WITH AN EXTENSION OF 15LF WRAPPING AROUND TOWARD EXPO 2. AT EXPO 4 APPROX 110 LF OF SIDEWALK SHED SHALL BE EREC TED ALONG FULL WIDTH OF THE FACADE W/ AN EXTENSION OF 15LF WRAPPING AR PUND TOWARD EXPO 3
DOB04/18/2025FAILURE TO MAINTAIN A BLDG IN A SAFE CONDITION.THE EXP 1/2 EXTERIOR MASONRY WALL NEAR THE ROOF CORNERS EXHIBITED SIGNIFICANT VERTICAL CRCKS,SEPARATION &IN THE BIRITY,POSNG A RISK OF.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,DETERMINE THE STRCTRL STBILITY.&PREPARE/ FILE RPAIR DWGS.BLDG TO BE RPAIRD
DOB04/18/2025EMERGENCY WORK ORDER.EXP1 ALONG 324 POWERS AVE&EXP4 ALONG E141ST THE EXP1/2&EXP3/4 EXTERIOR MASONRY WALLS NEAR THE ROOF CORNERS EXHIBITED SIGNIFICANT VERTICAL CRCKS,SEPARATION&POSNG RISK OF CLLPSE.OWNR TO IMMED RTAIN A NYSPE&DOB REG CNTRCTR TO 1.IMMED PRVDE TEMP BRACNG TO STBLIZE EXP1,2,3&4 WALLS,2.NYSPE TO SBMT MEANS
DOB04/17/2025CORRECTION ACTION PLAN REQ'D. OBSV @ EXP2 & EXP3 AN EXPANDING MASONRY CRACK APPROX 1/2 WIDE @ PARAPET LEVEL ALSO OBSV CRACK GLASS WINDOW ON THE 5FL OF EXP3 COURTYARD & SPALLING/CRACKED MASONRY @ CHIMNEY OWNER TO IMMED RETAIN REG DESING PROF TO EVAL ENTIRE BLDG & TO SUBMIT CORRECTIVE ACTION PLAN TO PROACTIVEINSP@BULDINGS.NYC.GOV W/IN 30DAYS
HPD01/25/2024§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD01/25/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX (25) SQ FT AT CEILING, SOUTH, AND WEST WALLS IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD01/25/2024§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD11/24/2023§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD11/24/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD11/24/2023§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD11/24/2023§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD11/24/2023§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD11/24/2023§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... TEN SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD11/24/2023§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST
HPD07/18/2022§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 3rd ROOM FROM EAST AT SOUTH, THE BATHROOM , THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/18/2022§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/18/2022§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD08/30/2021§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD08/30/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, WEST AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD08/30/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD08/30/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WINDOW CASINGS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD08/30/2021§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD08/24/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH SOUTH AND WEST WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD07/20/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD07/20/2021§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/28/2020HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/09/2019§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST AND EAST WALLS IN THE 1st BEDROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
HPD11/28/2017§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW SPRING BALANCES IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/28/2017§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW SPRING BALANCES IN THE 1st ROOM FROM NORTH LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB05/31/1994V-DOB VIOLATION - ACTIVE
ECB08/22/2025FAILURE TO COMPLY WITH THE COMMISSIONER'S PRDER #061325PI201025B AND CONTROL #34154 DATED 06/13/25. NO COMPLIANCE ON FILE FOR A CORRECTIVE ACTION PLAN. REMEDY: COMPLY WITH THE COMMISSIONER'S ORDER AND/OR FILE ANothing owed — awaiting certificate of correction