← Back
Elevator cooperative
325 EAST 77 STREET
💬 Discuss this project
1940Year Built
6Stories
D4Building Class
R8BZoning
54,774 sfGross Floor Area
59Units
LL97 CoveredRent Stabilized3 Open Violations ▸FISP: SWARMP
Elevator cooperative · Owner of record: 325 HOUSE INC · 12,738 sf lot · 4.3 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
Roof7p · 1 filing · 7 docs
Floor 6Under Construction4p · 1 filing · 12 docs
Floor 5
Floor 4
Floor 3
Floor 2
Floor 118p · 5 filings · 20 docs
Site & exterior9p · 2 filings · 9 docs
Filed — no permit issued19p · 3 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DERMER MANAGEMENT4207/08/2026
325 HOUSE2203/22/2026
325 HOUSE INC C O DERMER MGMT403/21/2026
325 HOUSE INC DERMER MANAG203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PAUL PERDEK, PROF. ENG. PLLC104/10/2025
LAWLESS & MANGIONE108/29/2024
STEVEN MICHAEL PETERSON STUDIOS508/01/2024
TAN ENGINEERING PC208/24/2022
UNI-D LLC508/01/2022
NDKAZALAS ARCHITECTURE P.C.403/04/2022
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DIMSO CONTRACTING INCGeneral Contractor603/21/2026
SKYLINE RESTORATION INCGeneral Contractor404/09/2026
NORTH SHORE ARCH STONEGeneral Contractor306/28/2026
ANGELO LELCAJ CORPGeneral Contractor303/21/2026
WATER DYNAMIC P & H CORPPlumbing207/08/2026
NYC IRONWORKERS LOCAL 40Electrical103/21/2026
MOLLER, GEORGEElectrical103/21/2026
SPRING SCAFFOLDING LLCGeneral Contractor104/09/2026
ZP CONSTRUCTION & RENOVATIONGeneral Contractor104/09/2026
DYNAMIC PLBG & SPRKLR CORPlumbing107/08/2026
NEW YORK PARK PLBG&HTG COPlumbing107/08/2026
CONDE ELECTRIC INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEO Y LEE ASSOCIATES2481405/14/2025
SPECIAL TESTING & CONSULT1688108/29/2024
RAND ENGINEERING & ARCHIT266208/01/2024
STEVEN MICHAEL PETERSON S2035306/11/2024
TAN ENGINEERING, P.C.1291208/24/2022
UNI-D7898508/01/2022
CONCRETE SOLUTIONS LAB CO5344403/04/2022
Building Lifecycle
All (141)Filed (22)Permit Issued (18)Signed Off (9)Facade (FISP) (3)Violation (26)Inspection (8)Objection (25)Special Inspection (30)
08/13/2026
Signed off — Alteration
M01054890-S3
08/11/2026
Signed off — Alteration
M01054890-I1
07/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/27/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/29/2026
Violation issued (HPD, closed)
A
04/02/2026
Permit issued — General Construction
M01054890-I1-GC
04/02/2026
Permit issued — Structural
M01054890-S3-ST
03/11/2026
Permit issued — Plumbing
M01021192-S1-PL
01/28/2026
Signed off — Alteration
HEAVY DUTY SIDEWALK SHED DURING BLDG ALTERATION, FILED SEP. SIDEWALK SHED SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION. THE SIDEWALK SHED IS IN FRONT OF THE MAIN ENTRANCE AT EAST 77TH STREET.
M01205856-I1
01/21/2026
Signed off — Alteration
M01095302-I1
01/14/2026
Permit issued — General Construction
M01054890-I1-GC
11/17/2025
Violation issued (HPD, closed)
I
10/20/2025
Signed off — Alteration
PROPOSED NON-STRUCTURAL INTERIOR RENOVATION INCLUDING THE RENOVATION OF THE KITCHEN AND BATHROOM. SCOPE SHALL ALSO INCLUDE PARTITION MODIFICATIONS AND FINISH MODIFICATIONS THROUGHOUT. NO CHANGE IN USE, EGRESS, OR OCCUPANCY IS PROPOSED IN THIS APPLICATION.
M01021192-I1
10/17/2025
Permit issued — Suspended Scaffold
M01119352-I1-SC
05/19/2025
Objection raised — Structural
05/19/2025
Objection resolved — Addressed
05/16/2025
Objection raised — Structural
05/16/2025
Objection resolved — Addressed
05/14/2025
Filed — Alteration
Installation of suspended scaffold for facade work and/or inspection. Amend #3, added scaffold drops and scaffold protection from welding work
M01119352-P3
05/14/2025
Special inspection requirement — Post-installed Anchors
Leo Lee
05/14/2025
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Leo Lee
04/10/2025
Filed — Alteration
HEAVY DUTY SIDEWALK SHED DURING BLDG ALTERATION, FILED SEP. SIDEWALK SHED SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION. THE SIDEWALK SHED IS IN FRONT OF THE MAIN ENTRANCE AT EAST 77TH STREET.
M01205856-I1
04/10/2025
Permit issued — Sidewalk Shed
M01205856-I1-SH
03/26/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/26/2025
Permit issued — Structural
M01095302-I1-GC
02/12/2025
Permit issued — General Construction
M01021192-I1-GC
11/22/2024
Objection resolved — Addressed
11/21/2024
Objection raised — Other
11/12/2024
Filed — Alteration
Installation of suspended scaffold for facade work and/or inspection. Amend #3, added scaffold drops and scaffold protection from welding work
M01119352-P2
11/12/2024
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Leo Lee
11/12/2024
Special inspection requirement — Post-installed Anchors
Leo Lee
11/08/2024
Permit issued — Suspended Scaffold
M01119352-P1-SC
10/29/2024
Filed — Alteration
Installation of suspended scaffold for facade work and/or inspection. Amend #3, added scaffold drops and scaffold protection from welding work
M01119352-P1
10/24/2024
Special inspection requirement — Post-installed Anchors
Leo Lee
10/24/2024
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Leo Lee
10/18/2024
Permit issued — General Construction
M01095302-I1-ST
10/17/2024
Permit issued — Structural
M01095302-I1-GC
10/16/2024
Permit issued — Suspended Scaffold
M01119352-I1-SC
10/07/2024
Filed — Alteration
Installation of suspended scaffold for facade work and/or inspection. Amend #3, added scaffold drops and scaffold protection from welding work
M01119352-I1
09/12/2024
Objection resolved — Addressed
09/12/2024
Objection resolved — Addressed
09/12/2024
Objection resolved — Addressed
09/10/2024
Objection raised — Scope
09/10/2024
Objection raised — Scope
09/10/2024
Objection raised — Admin
09/10/2024
Objection resolved — Addressed
09/10/2024
Objection raised — Energy
08/29/2024
Filed — Alteration
M01095302-I1
08/28/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/13/2024
Special inspection requirement — Masonry
SEBASTIAN SETTEDUCATE JR., P.E
08/13/2024
Special inspection requirement — Final
Kenneth Santelli
08/13/2024
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Santelli
08/13/2024
Special inspection requirement — Air barrier - visual inspection
Kenneth Santelli
08/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
SEBASTIAN SETTEDUCATE JR., P.E
08/13/2024
Special inspection requirement — Tenant Protection Plan Compliance
SEBASTIAN SETTEDUCATE JR., P.E
08/01/2024
Filed — Alteration
M01054890-S3
08/01/2024
Filed — Alteration
M01054890-I1
07/16/2024
Special inspection requirement — Tenant Protection Plan Compliance
Yevgeniy Gurevich
07/16/2024
Special inspection requirement — Exterior lighting power
Steven Peterson
07/16/2024
Special inspection requirement — Tenant Protection Plan Compliance
Yevgeniy Gurevich
Latest 60 of 141 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNORTH SHORE ARCH STONE04/02/2026
DOB NOWStructuralSigned-offNORTH SHORE ARCH STONE04/02/2026
DOB NOWPlumbingPermit IssuedNEW YORK PARK PLBG&HTG CO03/11/2026
DOB NOWGeneral ConstructionSigned-offNORTH SHORE ARCH STONE01/14/2026
DOB NOWSuspended ScaffoldPermit IssuedSKYLINE RESTORATION INC10/17/2025
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC04/10/2025
DOB NOWStructuralSigned-offSKYLINE RESTORATION INC02/26/2025
DOB NOWGeneral ConstructionSigned-offZP CONSTRUCTION & RENOVAT02/12/2025
DOB NOWSuspended ScaffoldPermit IssuedSKYLINE RESTORATION INC11/08/2024
DOB NOWGeneral ConstructionSigned-offSKYLINE RESTORATION INC10/18/2024
DOB NOWStructuralSigned-offSKYLINE RESTORATION INC10/17/2024
DOB NOWSuspended ScaffoldPermit IssuedSKYLINE RESTORATION INC10/16/2024
DOB NOWPlumbingSigned-offCITYWIDE PLBG HTG & SPKLS03/31/2022
DOB NOWGeneral ConstructionSigned-offANGELO LELCAJ CORP02/12/2022
DOB NOWGeneral ConstructionSigned-offDIMSO CONTRACTING INC01/04/2022
DOB NOWPlumbingSigned-offHYDRO PLBG & HTG CORP06/24/2021
DOB NOWPlumbingSigned-offHYDRO PLBG & HTG CORP06/08/2021
DOB NOWGeneral ConstructionSigned-offDIMSO CONTRACTING INC06/01/2021
BISOTISSUEDABCAT ASSOCIATES INC04/19/2019
BISOTISSUEDTARGET NEW YORK CONST.INC02/12/2015
BISPLISSUEDA & M WARSHAW PLBG & HTG01/14/2015
BISOTISSUEDTARGET NEW YORK CONST.INC12/18/2014
BISPLISSUEDA. HTG AND PLBG WORKS INC10/22/2014
BISOTISSUEDZEF RENOV. & CONTR. CORP10/15/2014
BISPLISSUEDCROWN PLUMBING INC10/02/2014
BISOTISSUEDAXIS INTERIOR DESIGN CORP08/12/2014
BISOTRE-ISSUEDDPC NEW YORK, INC06/28/2013
BISOTISSUEDD.P. CONSULTING, CORP06/12/2013
BISEQISSUEDEVEREST SCAFFOLDING INC04/16/2013
BISPLISSUEDTARDIO PLUMBING, LLC11/30/2012
BISFBISSUEDGEE CEE MECH SERVICE INC10/10/2012
BIS—ISSUEDVALUE WATER PROOFING INC07/16/2009
BISOTISSUEDK & G GEKON INC02/19/2008
BISPLISSUEDG.H. PLBG. & HTG. CORP.10/07/2002
BISOTISSUEDJ.J.S EMPIRE INC03/06/2002
BISOTISSUEDREMODELLA CORPORATION02/22/2001
BISPLISSUEDJ&M PLUMBING OF WESTCHESTER10/31/2000
BISMHISSUEDSHROID CONSTRUCTION INC10/05/2000
BISFSISSUEDBAYSIDE FUEL OIL CORP08/25/1998
BISOTISSUEDOWNER, SAME AS ABOVE06/30/1997
1 project · most recent 08/24/2022
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/24/2022——Ventilation Systems
Ventilation
__Junk__ Ductwork 1 CFM · Ductwork ×1
7 projects · most recent 06/10/2026
General Wiring
FiledStatusContractorScope
06/10/2026Permit IssuedJAM ELECTRICAL CORP—
09/22/2025CompleteEMPIRE LIC ELECL CONTRSGeneral Wiring
04/04/2025CompleteTOP SHELF ELECTRIC CORP—
10/28/2024Permit IssuedJTE ELECTRICAL SERVICES—
06/20/2022CompleteE & M ELECTRICAL NY CORPGeneral Wiring
06/10/2021CompleteCONDE ELECTRIC INCGeneral Wiring
01/22/2018CompleteDELCO ELECTRIC, INC—
1 project · most recent 05/14/2025
Suspended Scaffold (SC)
FiledStatusContractorScope
05/14/2025Permit IssuedSKYLINE RESTORATION INCSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
07/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/27/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/26/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/28/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/15/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/19/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/21/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/10/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
05/14/2025Post-installed AnchorsLeo Leespecial
05/14/2025Alternative Materials - OTCR Buildings Bulletin NumberLeo Leespecial
11/12/2024Alternative Materials - OTCR Buildings Bulletin NumberLeo Leespecial
11/12/2024Post-installed AnchorsLeo Leespecial
10/24/2024Post-installed AnchorsLeo Leespecial
10/24/2024Alternative Materials - OTCR Buildings Bulletin NumberLeo Leespecial
08/13/2024MasonrySEBASTIAN SETTEDUCATE JR., P.Especial
08/13/2024FinalKenneth Santelliprogress
08/13/2024Energy Code Compliance InspectionsKenneth Santelliprogress
08/13/2024Air barrier - visual inspectionKenneth Santellienergy_progress
08/13/2024Structural Stability – Alterations of existing buildingsSEBASTIAN SETTEDUCATE JR., P.Especial
08/13/2024Tenant Protection Plan ComplianceSEBASTIAN SETTEDUCATE JR., P.Especial
07/16/2024Tenant Protection Plan ComplianceYevgeniy Gurevichspecial
07/16/2024Exterior lighting powerSteven Petersonenergy_progress
07/16/2024Tenant Protection Plan ComplianceYevgeniy Gurevichspecial
07/16/2024MasonryYevgeniy Gurevichspecial
07/16/2024Structural Steel - DetailsYevgeniy Gurevichspecial
05/21/2024FinalSteven Petersonprogress
05/21/2024FinalYevgeniy Gurevichprogress
04/07/2024Energy Code Compliance InspectionsSteven Petersonprogress
03/17/2024Fire-Resistant Penetrations and JointsSteven Petersonspecial
03/17/2024Fire-Resistant Penetrations and JointsSteven Petersonspecial
03/17/2024FinalSteven Petersonprogress
03/17/2024Lighting in dwelling unitsSteven Petersonenergy_progress
03/17/2024Lighting controlsSteven Petersonenergy_progress
Latest 25 of 56.
▾Documents — 288 on file (BIS + DOB NOW)
▸Plans & Drawings22
▸DOB NOWPlans/Sketch22
09/04/2026M00485331-I1Request digital key ↗
09/04/2026M00485331-P1Request digital key ↗
09/04/2026M00485429-I1Request digital key ↗
Showing 3 of 22 on file for this type
▸Applications & Permits33
▸BISPLAN / WORK APPROVAL APPLICATION17
08/02/2019123417579Open ↗
07/31/2019123417579Open ↗
03/11/2019123417579Open ↗
Showing 3 of 17 on file for this type
▸BISWORK PERMIT APPLICATION15
04/19/2019123417579Open ↗
02/27/2015122174182Open ↗
01/28/2015122174182Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY APPLICATION1
07/22/2009120050050Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026M00627492-I1Open ↗
▸Seals & Professional Certifications102
▸DOB NOWProgress Inspector Seal & Signature30
09/02/2026M00670844-P2Open ↗
08/31/2026M00627492-I1Open ↗
08/31/2026M00627492-I1Open ↗
Showing 3 of 30 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION23
08/02/2019123417579Open ↗
03/11/2019123417579Open ↗
07/21/2015122078054Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature23
10/02/2026M01119352-P2Open ↗
10/02/2026M01119352-P2Open ↗
09/02/2026M00670844-P2Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature18
09/04/2026M00485331-P1Open ↗
09/04/2026M00485331-I1Open ↗
09/04/2026M00485429-I1Open ↗
Showing 3 of 18 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
10/11/2012121404122Open ↗
06/03/2009120050050Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
10/11/2012121404122Open ↗
06/03/2009120050050Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/15/2013140070330Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/15/2013140070330Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/15/2013140070330Open ↗
▸BISPC FULL REPORT1
02/05/2008110087575Open ↗
▸Trade Schedules & Equipment15
▸BISSELF-CERT PLUMBING NOTICE7
06/24/2015122106906Open ↗
06/04/2015122106906Open ↗
04/28/2015122174182Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING4
12/09/2014122174182Open ↗
10/13/2014122106906Open ↗
08/19/2014122078054Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
03/11/2019123417579Open ↗
11/05/2014122106906Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
10/11/2012121404122Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
03/14/2013121404122Open ↗
▸Safety & Tenant Protection3
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM2
06/12/2013121107364Open ↗
03/06/2013121107364Open ↗
▸BISTenant Protection Plan and Notes1
03/11/2019123417579Open ↗
▸Environmental & Asbestos27
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
09/04/2026M00485331-I1Open ↗
09/04/2026M00485331-P1Open ↗
09/04/2026M00485429-P1Open ↗
Showing 3 of 17 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
03/11/2019123417579Open ↗
10/11/2012121404122Open ↗
10/11/2012121404122Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
02/05/2008110087575Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
12/09/2014122174182Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP 20-21-5)1
06/11/2013121107364Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
06/03/2009120050050Open ↗
▸Energy Compliance21
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS11
08/02/2019123417579Open ↗
03/11/2019123417579Open ↗
07/31/2015122078054Open ↗
Showing 3 of 11 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS4
08/02/2019123417579Open ↗
07/21/2015122078054Open ↗
07/10/2015122174182Open ↗
Showing 3 of 4 on file for this type
▸BISTR8: Energy Code Progress Inspections4
12/09/2014122174182Open ↗
10/13/2014122106906Open ↗
08/19/2014122078054Open ↗
Showing 3 of 4 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
04/15/2013140070330Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
09/04/2026M00485331-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/15/2013140070330Open ↗
▸Approvals, Objections & Sign-offs17
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
08/02/2019123417579Open ↗
07/21/2015122078054Open ↗
07/10/2015122174182Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
10/11/2012121404122Open ↗
06/11/2012121107364Open ↗
06/03/2009120050050Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
07/10/2015122174182Open ↗
06/25/2014121404122Open ↗
06/23/2014140070330Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE3
04/05/2012120050050Open ↗
06/16/2009120050050Open ↗
06/03/2009120050050Open ↗
▸Cost, Insurance & Ownership20
▸BISCOST AFFIDAVIT16
08/02/2019123417579Open ↗
03/11/2019123417579Open ↗
07/21/2015122078054Open ↗
Showing 3 of 16 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT2
08/18/2014122078054Open ↗
08/18/2014122078054Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE2
07/26/2013121107364Open ↗
06/18/2013121107364Open ↗
▸Filing & Intake Forms15
▸BISEFILING COVER SHEET7
03/11/2019123417579Open ↗
12/09/2014122174182Open ↗
10/13/2014122106906Open ↗
Showing 3 of 7 on file for this type
▸BISADDITIONAL INFORMATION4
03/11/2019123417579Open ↗
12/09/2014122174182Open ↗
08/15/2014121107364Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM3
08/02/2019123417579Open ↗
08/02/2019123417579Open ↗
07/31/2019123417579Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/15/2013140070330Open ↗
▸Other Documents11
▸DOB NOWCalculations4
08/13/2026M01119352-I1Open ↗
08/13/2026M01119352-P1Open ↗
08/13/2026M01119352-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWManufacturer's Specifications4
08/13/2026M01119352-I1Open ↗
08/13/2026M01119352-P2Open ↗
08/13/2026M01119352-P3Open ↗
Showing 3 of 4 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
07/21/2015122078054Open ↗
10/17/2014122106906Open ↗
▸BISSupporting Document: Fee Exempt1
12/29/2014122174182Open ↗