← Back
BuildNYC
Walk-up apt, over six families with stores
327 1ST AVENUE
MANHATTAN · Gramercy · BIN 1081639
💬 Discuss this project
1880Year Built
4Stories
C7Building Class
C1-6AZoning
18,285 sfGross Floor Area
37Units
Rent Stabilized3 Active Violations 2 unresolved · 1 paperwork only 5 likely answered 1 old, status unconfirmed ▸
Walk-up apt, over six families with stores · Owner of record: Foxwood Realty · 7,360 sf lot · 2.48 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanical
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofKahen Properties1p · 1 filing · 7 docs
Floor 1Kahen Properties5p · 3 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Kahen Properties807/08/2026
Foxwood Realty403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
McCray Architect203/28/2023
Sustainable Design Engineering106/21/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YBL NY403/21/2026
Youber Design203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M. International EngineeringGeneral Contractor303/21/2026
Nurul AminGeneral Contractor203/21/2026
Amko Electric Construction & Maintenance IElectrical103/21/2026
Nurul AminScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. International Engineering3129103/28/2023
Building Lifecycle
All (32)Filed (3)Permit Issued (2)Signed Off (1)Violation (11)Special Inspection (15)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/18/2023
Permit issued — Mechanical Systems
M00844288-I1-GC-CX
03/29/2023
Violation issued (HPD, closed)
A
03/28/2023
Filed — Alteration
M00844292-I1
03/28/2023
Filed — Alteration
JOB FILED INTERIOR RENOVATION OF COMMERCIAL STORE INCLUDING NEW COUNTER AND EQUIPMENT AS PER PLAN. NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00844288-I1
03/15/2023
Special inspection requirement — HVAC-R and service water heating equipment
Kevin McCray
03/15/2023
Special inspection requirement — Shutoff dampers
Kevin McCray
03/15/2023
Special inspection requirement — Interior lighting power
Kevin McCray
03/15/2023
Special inspection requirement — Tenant Protection Plan Compliance
03/15/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/15/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
03/15/2023
Special inspection requirement — Mechanical Systems
NANIK MASSAND
03/15/2023
Special inspection requirement — Tenant Protection Plan Compliance
NANIK MASSAND
03/15/2023
Special inspection requirement — Energy Code Compliance Inspections
Kevin McCray
03/15/2023
Special inspection requirement — Final
Kevin McCray
03/15/2023
Special inspection requirement — HVAC-R and service water heating system controls
Kevin McCray
03/15/2023
Special inspection requirement — Maintenance information
Kevin McCray
03/15/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Kevin McCray
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/04/2019
Signed off — Alteration
INSTALLATION OF PLYWOOD CONSTRUCTION FENCE
M00183404-I1
09/09/2019
Permit issued — Construction Fence
M00183404-I1-FN
06/21/2019
Filed — Alteration
INSTALLATION OF PLYWOOD CONSTRUCTION FENCE
M00183404-I1
06/20/2019
Special inspection requirement — Preliminary
MOHAMMAD BILLAH
06/20/2019
Special inspection requirement — Final
MOHAMMAD BILLAH
02/21/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/21/2017
Violation issued (ECB, open)
Boilers
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/20/2007
Violation issued (ECB, closed)
Boilers
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedM. International Engineering05/18/2023
DOB NOWConstruction FenceSigned-offNithin Construction Co09/09/2019
BISOTISSUEDFacade Improvement06/10/2019
BISFPISSUEDUnique Fire Systems01/16/2014
BIS—ISSUEDUnitech Design12/31/2013
BISPLISSUEDOrion Plumbing & Heating09/09/2013
BISEQISSUEDKhatib Construction08/30/2013
BISOTISSUEDKhatib Construction08/30/2013
BISBLISSUEDNew York Heating07/02/2007
BISPLISSUEDNew York Heating07/02/2007
BISOTISSUEDG.S. Sign and Awning05/02/2003
BISOTISSUEDGS Sign & Awning04/10/2003
BISOTISSUEDG S Sign & Awning04/10/2003
BISOTISSUEDGS Sign & Awning04/10/2003
BISFPISSUEDAvon Plumbing & Heating09/27/1999
BISFPISSUEDMaster Fire Prevention Systems08/22/1997
BISPLISSUEDC.R.U. Mechan & Heating08/04/1997
BISOTISSUEDWagner/Weintraub PLG Heating Enterprises07/28/1997
1 project · most recent 03/28/2023
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/28/2023Permit IssuedM. International EngineeringVentilation Systems
Ventilation
Floaire BDU24 4,800 CFM · Exhaust Fan ×1
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
03/15/2023HVAC-R and service water heating equipmentKevin McCrayenergy_progress
03/15/2023Shutoff dampersKevin McCrayenergy_progress
03/15/2023Interior lighting powerKevin McCrayenergy_progress
03/15/2023Tenant Protection Plan Compliance—special
03/15/2023Fire-Resistant Penetrations and Joints—special
03/15/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
03/15/2023Mechanical SystemsNANIK MASSANDspecial
03/15/2023Tenant Protection Plan ComplianceNANIK MASSANDspecial
03/15/2023Energy Code Compliance InspectionsKevin McCrayprogress
03/15/2023FinalKevin McCrayprogress
03/15/2023HVAC-R and service water heating system controlsKevin McCrayenergy_progress
03/15/2023Maintenance informationKevin McCrayenergy_progress
03/15/2023HVAC-R and service water piping design and insulationKevin McCrayenergy_progress
06/20/2019PreliminaryMOHAMMAD BILLAHprogress
06/20/2019FinalMOHAMMAD BILLAHprogress
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch2
08/31/2026M00844288-I1Request digital key ↗
08/31/2026M00844292-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/05/2026M00183404-I1Request digital key ↗
▸Applications & Permits15
▸BISWORK PERMIT APPLICATION9
09/19/2019123780756Open ↗
06/10/2019123780756Open ↗
01/22/2014121664270Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
05/22/2019123780756Open ↗
01/06/2014121664270Open ↗
11/01/2013121829361Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026M00844288-I1Open ↗
09/01/2026M00844288-I1Open ↗
09/01/2026M00844288-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026M00844292-I1Open ↗
08/13/2026M00183404-I1Open ↗
08/13/2026M00844288-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
05/22/2019123780756Open ↗
09/06/2013121765090Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
05/22/2019123780756Open ↗
09/06/2013121765090Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/22/2019123780756Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/06/2013121765090Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026M00844288-I1Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING2
10/04/2013121765090Open ↗
09/06/2013121765090Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
10/26/2013121765090Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
10/03/2014121664270Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
05/22/2019123780756Open ↗
▸Environmental & Asbestos6
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
05/22/2019123780756Open ↗
11/01/2013121829361Open ↗
11/01/2013121829370Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026M00844288-I1Open ↗
08/13/2026M00844292-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/22/2019123780756Open ↗
09/06/2013121765090Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
03/04/2014121829370Open ↗
03/04/2014121829361Open ↗
10/03/2014121664270Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/06/2014121829370Open ↗
▸BISSUPERSEDING LETTER1
09/19/2019123780756Open ↗
▸Cost, Insurance & Ownership9
▸BISCOST AFFIDAVIT8
05/22/2019123780756Open ↗
10/03/2014121664270Open ↗
03/04/2014121829370Open ↗
Showing 3 of 8 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
06/10/2019123780756Open ↗
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET5
05/22/2019123780756Open ↗
01/06/2014121664270Open ↗
11/01/2013121829361Open ↗
Showing 3 of 5 on file for this type
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/01/2013121829361Open ↗