← Back
Miscellaneous one family
327 AVENUE P
BROOKLYN · BIN 3174641
💬 Discuss this project
1920Year Built
2Stories
A9Building Class
R4-1Zoning
1,424 sfGross Floor Area
1Units
Miscellaneous one family · 2,475 sf lot · 0.58 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 22p · 1 filing · 16 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HECAN CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/17/2024$980K—Private party → Private party$688/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LU ENGINEERING SERVICE PC207/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H Z BUILDING NY403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GOODALL ELECTRIC CORPElectrical103/22/2026
HECAN CONSTRUCTION CORPGeneral Contractor107/08/2026
TRI STATE PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LU ENGINEERING SERVICE PC6575207/30/2024
Building Lifecycle
All (20)Filed (2)Permit Issued (2)Signed Off (2)Inspection (6)Special Inspection (8)
02/28/2025
Signed off — Alteration
PROPOSED INTERIOR RENOVATION ON OSP, CEL, 1ST & 2ND FLOOR, REPAIRING PARTITION, FLOORING, CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01087014-I1
02/28/2025
Signed off — Alteration
PROPOSED INTERIOR RENOVATION ON OSP, CEL, 1ST & 2ND FLOOR, REPAIRING PARTITION, FLOORING, CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01087014-S1
01/27/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/21/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/08/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/08/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/30/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/15/2024
Permit issued — Plumbing
B01087014-S1-PL
08/09/2024
Permit issued — General Construction
B01087014-I1-GC
07/30/2024
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON OSP, CEL, 1ST & 2ND FLOOR, REPAIRING PARTITION, FLOORING, CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01087014-I1
07/30/2024
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON OSP, CEL, 1ST & 2ND FLOOR, REPAIRING PARTITION, FLOORING, CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01087014-S1
07/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DONGSHENG LU
07/26/2024
Special inspection requirement — Energy Code Compliance Inspections
DONGSHENG LU
07/26/2024
Special inspection requirement — Fire-Resistance Rated Construction
DONGSHENG LU
07/26/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
DONGSHENG LU
07/26/2024
Special inspection requirement — Fenestration air leakage
DONGSHENG LU
07/26/2024
Special inspection requirement — Fenestration areas
DONGSHENG LU
07/26/2024
Special inspection requirement — Air barrier - visual inspection
DONGSHENG LU
07/26/2024
Special inspection requirement — Interior lighting power
DONGSHENG LU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDW PLUMBING INC08/15/2024
DOB NOWGeneral ConstructionSigned-offHECAN CONSTRUCTION CORP08/09/2024
1 project · most recent 12/14/2024
General Wiring
FiledStatusContractorScope
12/14/2024CompleteGOODALL ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/27/2025Pass-Final General Construction Non-Directive 14PassView ↗
01/21/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/08/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/08/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/30/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/30/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/26/2024Fire-Resistant Penetrations and JointsDONGSHENG LUspecial
07/26/2024Energy Code Compliance InspectionsDONGSHENG LUprogress
07/26/2024Fire-Resistance Rated ConstructionDONGSHENG LUprogress
07/26/2024Fenestration and door U-factor and product ratingsDONGSHENG LUenergy_progress
07/26/2024Fenestration air leakageDONGSHENG LUenergy_progress
07/26/2024Fenestration areasDONGSHENG LUenergy_progress
07/26/2024Air barrier - visual inspectionDONGSHENG LUenergy_progress
07/26/2024Interior lighting powerDONGSHENG LUenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026B01087014-I1Request digital key ↗
08/24/2026B01087014-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B01087014-S1Open ↗
08/13/2026B01087014-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature7
08/26/2026B01087014-I1Open ↗
08/26/2026B01087014-I1Open ↗
08/26/2026B01087014-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026B01087014-I1Open ↗
08/24/2026B01087014-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B01087014-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026B01087014-I1Open ↗
08/24/2026B01087014-S1Open ↗