DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB12/08/2020FAILURE TO COMPLY W/COMMISH ORDR 327 BLEECKER ST. IS A STRCTLY COMPROM BLD CURRNT BEING SHORE UNDR PRMT#123412962.EMRG DEMO WILL COMMENC IMMD SHOR ALNG CHRISTOPHER&BLEECKER ST. INSTLD HOWEVER OPS. WILL REQ ACCESS PUBL/SFTY/MESURES ON 323 BLEECKER ST. OWN FAILE TO COMPLY W/DOB COMISH ORDR TO INSTALL PUBLC SFTY MEASURES FOR SAFE EMERG OPS. COMPLY W/CODE
DOB10/08/2020IMMED EMGY WORK ORDER:BLDG SEVRELY DETER&ROTTEN WD JOIST,END JOIST NOT FULLY BEAR ON BEAR WALLS FRM 2-4FLR.BLDG HAS INSUFF SHRNG INSTALLED.8" BEAR WALLS SEVERE DISRPR W/BUCK&CRACKS THR-OUT &STRUCTLY COMPR.BLDG IS UNSAFE.OWNR IMMD ENGAG PE&ENDORSE CONTR SHORE UNSAFE CONDNS&FULLY DEMO BLD.WRK UNDR SUPV PE.FILE WRK PRMT W/IN 2BUSN DAY.SIGNOFF NLT 11/16/20
DOB10/08/2020IMMED EMGY WORK ORDER:BLDG SEVRELY DETER&ROTTEN WD JOIST,END JOIST NOT FULLY BEAR ON BEAR WALLS FROM 2-4FLR.BLDG HAS INSUFF SHRNG INSTALED.8" BEAR WALLS SEVERE DISRPR W/BUCK&CRACKS THR-OUT &STRUCTLY COMPR.BLDG IS UNSAFE.OWNR IMMD ENGAG PE&ENDORSE CONTR SHORE UNSAFE CONDNS&FULLY DEMO BLD.WRK UNDR SUPV PE.FILE WRK PRMT W/IN 2 BUSN DAYS.SIGNOFF NL 11/16/2
DOB03/14/2020FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. BUILDING IS IN A STATE OF DISREPAIR. REMEDY:COMPLY WITH CODE. MAKE FACADE REPAIRS TO MAKE BUILDING SAFE
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB03/22/2018FTM BLDG IN SAFE COND.BLDG LOCALLY ROTTEN JOISTS AT KITCHENS AREAS FROM 2ND-4THFLRS FRAMING.END JOISTS AT SEVERAL LOCS ARE NOT FULLY BEARING ON NORTH BEAR WALL FROM 2ND TO 4THFL.NORTH EXT WALL BULGING OUT BET 1ST&2NDFLRS.REMEDY:OWN ENGAGE PE&CONT'R EVAL BLDG&OBTAIN PERM FOR RPRS/DEMO NO LATER 5/29/18.PERM JOB SIGNED OFF NO LATER 12/31/18
DOB03/15/2018EMERG WRK ORDER.BLDG HAS LOCALLY ROTTEN JOISTS AT KITCHEN AREAS FROM 2NDFL UP.END JOISTS AT SEVERAL LOCS ARE NOT FULLY BEAR ON NORTH WALL FROM 2ND TO 4THFL PARALLEL TO BLDG NORTH WALL THERE IS EXIST INCOMP SHORING FROM CELL TO ROOF.REMEDY:OWN IMMED ENGAGE ENG&CONT'R TO CONT EXIST SHORING FROM 2ND TO 1STFL&CELL.FILING FOR WRK W/2 BUS DAYS
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB02/01/2014FAILURE TO MAINTAIN BUILDING DUE TO TRUCK STRIKING SIDEWALK SHED
HPD10/21/2007SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BUIGING BRICK WORK FRONT PARAPET WALL , 4th STORY
DOB08/27/2004V-DOB VIOLATION - ACTIVE
DOB12/05/2000VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB09/11/2000V-DOB VIOLATION - ACTIVE
ECB06/12/2018PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE: AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED ON SITE W/THE FOLLOWING OBJECTIONS: DAMAGED/MISPLACED MUDSILLS-EXPOSED BOLTS-VERTICAL POST OUT OF PLUNothing owed — awaiting certificate of correction
ECB02/11/2011FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCE DEFECTS NOTED AT TIME OF INSP BRICK WALL AT NORTH ELEVATION IS BULGING AND LEANING OUT OF PLUMB TOWARDS PEDESTRIAN SIDEWALK CRACKS AND OBSERVED IN BRICK AND SEPERANothing owed — awaiting certificate of correction
ECB06/01/2010FAIL TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.NOTED:@ NORTH ELEVATION OF LANDMARKED BLDG BRICK FACADE IS CRACKED & BULGING @ 1ST STORY ABOVE DOOR/WINDOW HEADERS (LINTELS) W/CRACKED BRICKS IN VARIOUS LOCATIONSNothing owed — awaiting certificate of correction
ECB04/19/2010FAIL TO MAINTAIN EXTERIOR WALL. NOTED: AT THE NORTH EXPOSURE ABOVE THEDOOR WINDOW OPENING CRACKS EXIST, THE PARAPET IS SHOWING SIGNS OF WAT ER DAMAGE. CRACKS ARE PARAPET BOTH VERTICAL & DIAGONAL THRU OUT NORTHNothing owed — awaiting certificate of correction
ECB01/18/20051)HAVING AN ADULT ESTABLISHMENT IN A C-1 DISTRICT.LOCATION FAILS TO COMPLY WITH 60/40 LAW.PHOTOS.2)FAILURE TO COMPLY WITH THE COMMISIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB FOR VIOLATION 34Nothing owed — awaiting certificate of correction
ECB08/27/2004HAVING THREE (03) PARALLEL WALL SIGNS WHICH PROJECT MORE THAN 12" ACROSS THE STREET LINE IN A C-1 DISTRICT. REMEDY: REMOVE ILLEGAL SIGNAGE (PHOTOS)Nothing owed — awaiting certificate of correction
ECB12/05/2000WORK W/O PERMIT:NOTED:ROLL DOWN GATE A FRONT ENTRANCE OF 1ST STORY STORE CALLED "BLEECKER GROCERY" HAS BEEN INSTALLED W/O OBTAINING A PERMIT WITH D.O.B. WORK COMPLETED.REMEDY:OBTAIN PERMIT FROM D.O.B. OR REMOVENothing owed — awaiting certificate of correction