← Back
Walk-up apt, over six families with stores
327 EAST 12 STREET
MANHATTAN · East Village · BIN 1006504
💬 Discuss this project
1900Year Built
6Stories
C7Building Class
R8BZoning
12,804 sfGross Floor Area
24Units
Rent Stabilized0 Open Violations
Walk-up apt, over six families with stores · Owner of record: EVP 327 EAST 12TH ST LLC · 2,779 sf lot · 4.61 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingEquipment
Floor 64p · 2 filings · 20 docs
Floor 510p · 2 filings · 10 docs
Floor 411p · 2 filings · 10 docs
Floor 314p · 4 filings · 20 docs
Floor 211p · 3 filings · 14 docs
Floor 118p · 5 filings · 20 docs
Cellar3p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SILVERSTONE PROPERTY GROUP6007/08/2026
TABAK ASSOCIATES1603/21/2026
325 E 12TH STREET1403/21/2026
HKS CONSTRUCTION404/09/2026
444 EAST 13TH LLC203/21/2026
EVP 327 EAST 12TH ST LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/23/2021$11.7M—327 EAST 12TH STREET LLC → EVP 327 EAST 12TH ST LLC$913/sf building
09/10/2015$6.7M—TABAK ASSOCIATES, L.L.C. → 327 EAST 12TH STREET LLC$525/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN FENG, ARCHITECT310/02/2024
UNFOLD ARCHITECT, PC902/23/2023
AM ARCHITECTURE PLLC711/12/2021
HAIDER ENGINEERING, P.E.108/30/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338603/21/2026
HTX BUILDING CONSULTING403/21/2026
PWF1403/21/2026
HAIDER ENGINEERING, P.E.103/21/2026
HAIDER ENGINEERING P E103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KG MANAGEMENT CNSLTNG INCGeneral Contractor1107/08/2026
CENTRAL FIVE HOME IMPROVEGeneral Contractor907/08/2026
KG USA MANAGEMENT INCGeneral Contractor407/08/2026
HIGH QUALITY CONSTRUCTIONGeneral Contractor403/21/2026
PIPESTYLISTS, INCPlumbing307/08/2026
JOSEPH LA VOLPEElectrical203/21/2026
STEWART, DUDLEYElectrical103/21/2026
HKS CONSTRUCTION CORPGeneral Contractor104/09/2026
VAN KLEECK, ADAMElectrical103/21/2026
JORDAN, JOSEPHElectrical103/21/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
ASHLEY, ANTHONYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802310/02/2024
NKM ENGINEERING PLLC6244108/01/2024
UNFOLD ARCHITECT77071011/09/2022
Building Lifecycle
All (152)Filed (20)Permit Issued (21)Signed Off (9)Violation (60)Inspection (15)Objection (12)Special Inspection (15)
10/22/2025
Signed off — Alteration
M00073547-I1
10/11/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/10/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/02/2024
Filed — Alteration
FILE PLUMBING WORK IN CONJUNCTION WITH JOB# M01082965. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01088599-P1
10/01/2024
Special inspection requirement — Tenant Protection Plan Compliance
10/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chun Feng
10/01/2024
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
08/07/2024
Permit issued — General Construction
M01082965-I1-MS
08/07/2024
Permit issued — Plumbing
M01088599-I1-PL
08/06/2024
Permit issued — Mechanical Systems
M01082965-I1-GC
08/01/2024
Filed — Alteration
M01082965-I1
08/01/2024
Filed — Alteration
FILE PLUMBING WORK IN CONJUNCTION WITH JOB# M01082965. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01088599-I1
01/10/2024
Signed off — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00728849-I1
03/10/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JINHO KIM
02/23/2023
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00728849-P3
02/14/2023
Objection resolved — Addressed
02/09/2023
Objection raised — Accessibility
01/18/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/03/2023
Signed off — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 9 &10, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00775362-I1
12/28/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/21/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/22/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/15/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00728849-P2
11/09/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 9 &10, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00775363-P1
11/08/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00754333-P1
11/08/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00728849-P1
11/08/2022
Special inspection requirement — Energy Code Compliance Inspections
JINHO KIM
11/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JINHO KIM
10/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/19/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JINHO KIM
10/06/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/13/2022
Permit issued — Plumbing
M00754333-I1-PL
09/07/2022
Permit issued — General Construction
M00728849-I1-GC
09/07/2022
Permit issued — General Construction
M00775362-I1-GC
08/24/2022
Permit issued — Plumbing
M00775363-I1-PL
08/12/2022
Permit issued — General Construction
M00775362-I1-GC
08/12/2022
Permit issued — General Construction
M00728849-I1-GC
07/21/2022
Violation issued (HPD, closed)
C
07/21/2022
Violation issued (HPD, closed)
C
07/21/2022
Violation issued (HPD, closed)
C
07/21/2022
Violation issued (HPD, closed)
C
07/21/2022
Violation issued (HPD, closed)
B
07/20/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 9 &10, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00775362-I1
07/20/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 9 &10, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00775363-I1
07/20/2022
Special inspection requirement — Lighting in dwelling units
JINHO KIM
07/20/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JINHO KIM
07/13/2022
Objection raised — Energy
07/13/2022
Objection resolved — Addressed
07/13/2022
Objection raised — Fire_Protection
07/13/2022
Objection resolved — Addressed
07/13/2022
Objection raised — Admin
07/13/2022
Objection resolved — Addressed
07/13/2022
Objection raised — Energy
07/13/2022
Objection resolved — Addressed
07/13/2022
Objection raised — Fire_Protection
07/13/2022
Objection resolved — Addressed
06/29/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00728849-I1
06/29/2022
Filed — Alteration
FILE MINOR RENOVATION TO COMBINE EXISTING APARTMENT UNITS 19 &20, NO CHANGE OF USE, EGRESS, OR OCCUPANCY
M00754333-I1
03/03/2022
Signed off — Alteration
FILING FOR PLUMBING WORK IN CONJUNCTION WITH ALT GC APPLICATION #s M00512167, M00512097, M00512051, M00512015, M00511884.
M00512201-I1
Latest 60 of 152 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION08/07/2024
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.08/07/2024
DOB NOWMechanical SystemsPermit IssuedHIGH QUALITY CONSTRUCTION08/06/2024
DOB NOWPlumbingPermit IssuedT & T PLUMBING INC09/13/2022
DOB NOWGeneral ConstructionSigned-offKG USA MANAGEMENT INC09/07/2022
DOB NOWGeneral ConstructionSigned-offKG USA MANAGEMENT INC09/07/2022
DOB NOWPlumbingPermit IssuedT & T PLUMBING INC08/24/2022
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/12/2022
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/12/2022
DOB NOWPlumbingSigned-offT & T PLUMBING INC08/26/2021
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/23/2021
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/23/2021
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/23/2021
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/23/2021
DOB NOWGeneral ConstructionSigned-offKG MANAGEMENT CNSLTNG08/23/2021
DOB NOWGeneral ConstructionSigned-offCENTRAL FIVE HOME IMPROVE05/17/2021
DOB NOWGeneral ConstructionSigned-offCENTRAL FIVE HOME IMPROVE05/17/2021
DOB NOWGeneral ConstructionSigned-offCENTRAL FIVE HOME IMPROVE05/17/2021
DOB NOWGeneral ConstructionSigned-offCENTRAL FIVE HOME IMPROVE05/17/2021
DOB NOWGeneral ConstructionSigned-offCENTRAL FIVE HOME IMPROVE05/17/2021
DOB NOWSidewalk ShedSigned-offHKS CONSTRUCTION CORP08/31/2018
BISOTISSUEDCDP GENERAL CONTRACTORS L11/10/2016
BISPLISSUEDALL PRO PLBG & HTG INC05/27/2016
BISOTISSUEDCDP GENERAL CONTRACTORS L04/06/2016
BISPLISSUEDE.P. PLUMBING CO04/05/2016
BISOTISSUEDCDP GENERAL CONTRACTORS L02/26/2016
BISPLISSUEDALL PRO PLBG & HTG INC02/03/2016
BISOTISSUEDCDP GENERAL CONTRACTORS L12/10/2015
BISOTISSUEDA LITTLE OF EVERYTHING CO05/06/2015
BISPLISSUEDATLANTIS PLBG&HTG CORP11/14/2014
BISPLISSUEDATLANTIS PLBG&HTG CORP11/14/2014
BISOTISSUEDA LITTLE OF EVERYTHING CO10/21/2014
BISOTISSUEDA LITTLE OF EVERYTHING CO10/20/2014
BISOTISSUEDA LITTLE OF EVERYTHING CO11/07/2011
BISPLISSUEDARIANA CONTRACTING INC08/16/2009
BISPLISSUEDARIANA CONTRACTING INC10/02/2008
BISOTISSUEDFLUX CONTRACTING LLC09/29/2008
BISPLISSUEDARIANA CONTRACTING INC08/11/2008
BISOTISSUEDFLUX CONTRACTING LLC07/23/2008
BISOTISSUEDMORTON TABAK & CO05/19/2008
+ 11 more permits on file
3 projects · most recent 10/02/2024
Water/Sanitary Gas
FiledStatusContractorScope
10/02/2024Permit IssuedAMERICAN STANDARD P&H CORWater/Sanitary
11/09/2022Permit IssuedT&T PLUMBING INCGas, Water/Sanitary
11/08/2022Permit IssuedT&T PLUMBING INCWater/Sanitary
6 projects · most recent 08/09/2024
General Wiring
FiledStatusContractorScope
08/09/2024CompleteE D ELECTRICAL INCGeneral Wiring
08/19/2022CompleteE & M ELECTRICAL NY CORPGeneral Wiring
08/04/2022Permit IssuedE & M ELECTRICAL NY CORPGeneral Wiring
01/26/2022CompleteE & M ELECTRICAL NY CORPGeneral Wiring
05/31/2021Permit IssuedRIGHT AWAY ELECTRIC LLCGeneral Wiring
08/30/2018CompleteRICHARD NEU—
▾Field Inspections (DOB CAP) — 15
DateTypeResultReport
10/11/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/10/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/10/2023Pass-Final General Construction Non-Directive 14PassView ↗
01/18/2023Pass-Final CND-Occupancy InspectionPassView ↗
12/28/2022Pass-Final General Construction Non-Directive 14PassView ↗
12/21/2022Fail-Final General Construction Non-Directive 14FailView ↗
11/22/2022Fail-Final General Construction Non-Directive 14FailView ↗
10/24/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/06/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/18/2022Pass-Final General Construction Non-Directive 14PassView ↗
02/04/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/04/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/04/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/03/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/27/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
10/01/2024Tenant Protection Plan Compliance—special
10/01/2024Fire-Resistant Penetrations and JointsChun Fengspecial
10/01/2024Energy Code Compliance InspectionsChun Fengprogress
02/24/2023Fire-Resistant Penetrations and JointsJINHO KIMspecial
11/08/2022Energy Code Compliance InspectionsJINHO KIMprogress
11/08/2022Fire-Resistant Penetrations and JointsJINHO KIMspecial
10/19/2022Fire-Resistant Penetrations and JointsJINHO KIMspecial
07/20/2022Lighting in dwelling unitsJINHO KIMenergy_progress
07/20/2022Fire-Resistant Penetrations and JointsJINHO KIMspecial
04/28/2021Lighting in dwelling unitsJINHO KIMenergy_progress
04/28/2021Fire-Resistant Penetrations and JointsJINHO KIMspecial
04/28/2021Lighting in dwelling unitsJINHO KIMenergy_progress
04/28/2021Energy Code Compliance InspectionsJINHO KIMprogress
04/28/2021Fire-Resistant Penetrations and JointsJINHO KIMspecial
04/28/2021Energy Code Compliance InspectionsJINHO KIMprogress
▾Documents — 259 on file (BIS + DOB NOW)
▸Plans & Drawings20
▸DOB NOWPlans/Sketch20
09/06/2026M00073547-I1Request digital key ↗
09/03/2026M00511884-I1Request digital key ↗
09/03/2026M00512097-I1Request digital key ↗
Showing 3 of 20 on file for this type
▸Applications & Permits41
▸BISPLAN / WORK APPROVAL APPLICATION21
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 21 on file for this type
▸BISWORK PERMIT APPLICATION20
11/15/2016122518329Open ↗
06/07/2016122661075Open ↗
04/14/2016122661075Open ↗
Showing 3 of 20 on file for this type
▸Seals & Professional Certifications66
▸DOB NOWDPL-1: Design Professional Seal & Signature20
09/03/2026M00512015-I1Open ↗
09/03/2026M00512051-I1Open ↗
09/02/2026M00775362-I1Open ↗
Showing 3 of 20 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/07/2026M00512097-I1Open ↗
09/01/2026M01088599-P1Open ↗
08/31/2026M00775363-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/07/2026M00512097-I1Open ↗
09/07/2026M00512097-I1Open ↗
09/01/2026M01088599-P1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
11/09/2011120887889Open ↗
09/29/2008110345038Open ↗
07/22/2008110293888Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
11/09/2011120887889Open ↗
09/29/2008110345038Open ↗
05/15/2008110170760Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
▸BISPC FULL REPORT2
02/05/2008110087398Open ↗
11/09/2007110013182Open ↗
▸Trade Schedules & Equipment24
▸BISSELF-CERT PLUMBING NOTICE11
12/29/2015140266548Open ↗
10/02/2015140266548Open ↗
03/10/2015140266548Open ↗
Showing 3 of 11 on file for this type
▸BISSCHEDULE B - PLUMBING8
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
Showing 3 of 8 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
04/12/2016122661075Open ↗
02/24/2016122638921Open ↗
12/18/2015122518329Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection4
▸BISTenant Protection Plan and Notes4
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos38
▸DOB NOWDEP ACP-5: Asbestos Assessment Report19
09/03/2026M00512015-I1Open ↗
09/03/2026M00512051-I1Open ↗
09/02/2026M00775362-I1Open ↗
Showing 3 of 19 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)10
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 10 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'9
11/09/2011120887889Open ↗
09/29/2008110345038Open ↗
07/24/2008110293888Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance18
▸DOB NOWEN2: As Built Energy Analysis.6
08/13/2026M00512097-I1Open ↗
08/13/2026M00511884-I1Open ↗
08/13/2026M00512167-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
▸BISTECHNICAL REPORT: ENERGY1
11/09/2011120887889Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
▸Approvals, Objections & Sign-offs8
▸BISADMINISTRATIVE OBJECTIONS6
11/09/2011120887889Open ↗
09/29/2008110345038Open ↗
07/22/2008110293888Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
06/19/2014110345038Open ↗
02/12/2009110087398Open ↗
▸Cost, Insurance & Ownership21
▸BISCOST AFFIDAVIT16
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 16 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT5
01/08/2016122518329Open ↗
11/09/2011120887889Open ↗
11/09/2011120887889Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms14
▸BISEFILING COVER SHEET8
08/03/2016122714447Open ↗
06/24/2016122724203Open ↗
04/12/2016122661075Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
05/04/2015140343279Open ↗
10/16/2014140266548Open ↗
10/16/2014140266584Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION2
03/13/2015140266548Open ↗
10/27/2014140266548Open ↗
▸Other Documents2
▸BISPC FILING CLUSTER DETAILS1
07/22/2008110293888Open ↗
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
08/13/2026M00073547-I1Open ↗