← Back
Two family brick
33-32 73 STREET
QUEENS · Jackson Heights · BIN 4028610
💬 Discuss this project
1930Year Built
3Stories
B1Building Class
R5Zoning
2,280 sfGross Floor Area
2Units
0 Open Violations
Two family brick · 2,450 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 13 docs
Floor 31p · 1 filing · 6 docs
Floor 2
Floor 11p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/18/2022$1.2M—— → —$535/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JIMENEZ BUILDING CONSULTING LLC508/07/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SD DESIGN STUDIO403/21/2026
JRL SKYLINE603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WINWAY DEVELOPMENT LLCGeneral Contractor603/21/2026
R & T ELECTRICAL CORPElectrical103/22/2026
MES CONSTRUCTION CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010307/19/2022
Building Lifecycle
All (54)Filed (5)Permit Issued (3)Signed Off (3)Violation (7)Inspection (7)Objection (16)Special Inspection (13)
10/11/2023
Signed off — Alteration
PROPOSE FILE APPLICATION TO RENOVATION ON CEL, 1ST, 2ND & 3RD FLOOR. FLOORING, CEILING & PARTITIONS WORKS AS PER PLAN. NO CHANGE IN USE, EGRESS, BULK OR OCCUPANCY.
Q00702002-I1
10/10/2023
Signed off — Alteration
PROPOSE INTERIOR RENOVATION ON CELLAR, 1ST THRU 3RD FLOOR. PLUMBING & GAS WORKS AS PER PLAN. THIS APPLICATION IS IN CONJUNCTION WITH GC #: Q00702002. NO CHANGE OF USE EGRESS AND OCCUPANCY.
Q00704092-I1
10/06/2023
Signed off — Alteration
PROPOSED INTERIOR RENOVATION ON 1ST & 3RD FLOOR. REMOVE ILLEGAL MINOR WALL PARTITIONS. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. REMEDY TO CURE DOB VIOLATIONS #: 35670069Z, 35670070X, 35670071H, 35670072J, 35670073L. NO CHANGE IN USE, EGRESS OR OCC
Q00895823-I1
08/24/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/07/2023
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON 1ST & 3RD FLOOR. REMOVE ILLEGAL MINOR WALL PARTITIONS. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. REMEDY TO CURE DOB VIOLATIONS #: 35670069Z, 35670070X, 35670071H, 35670072J, 35670073L. NO CHANGE IN USE, EGRESS OR OCC
Q00895823-P1
07/31/2023
Permit issued — General Construction
Q00895823-I1-GC
07/13/2023
Objection resolved — Addressed
07/05/2023
Objection raised — Zoning
06/27/2023
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON 1ST & 3RD FLOOR. REMOVE ILLEGAL MINOR WALL PARTITIONS. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. REMEDY TO CURE DOB VIOLATIONS #: 35670069Z, 35670070X, 35670071H, 35670072J, 35670073L. NO CHANGE IN USE, EGRESS OR OCC
Q00895823-I1
06/22/2023
Violation issued (ECB, closed)
Construction
06/21/2023
Violation issued (ECB, closed)
Construction
06/21/2023
Violation issued (ECB, closed)
Construction
06/21/2023
Violation issued (ECB, closed)
Quality of Life
06/21/2023
Violation issued (ECB, closed)
Construction
06/21/2023
Violation issued (ECB, closed)
Quality of Life
06/21/2023
Violation issued (ECB, closed)
Quality of Life
10/10/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/05/2022
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
10/04/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
07/27/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
XIUCHENG LI
07/27/2022
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
07/27/2022
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
07/27/2022
Special inspection requirement — Interior lighting power
XIUCHENG LI
07/27/2022
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
07/27/2022
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
07/27/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
07/27/2022
Special inspection requirement — Air barrier — testing
XIUCHENG LI
07/27/2022
Special inspection requirement — Fenestration areas
XIUCHENG LI
07/27/2022
Special inspection requirement — Maintenance information
XIUCHENG LI
07/27/2022
Special inspection requirement — Fenestration air leakage
XIUCHENG LI
07/27/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
XIUCHENG LI
07/19/2022
Filed — Alteration
PROPOSE FILE APPLICATION TO RENOVATION ON CEL, 1ST, 2ND & 3RD FLOOR. FLOORING, CEILING & PARTITIONS WORKS AS PER PLAN. NO CHANGE IN USE, EGRESS, BULK OR OCCUPANCY.
Q00702002-P1
06/24/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/24/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/04/2022
Permit issued — Plumbing
Q00704092-I1-PL
05/03/2022
Permit issued — General Construction
Q00702002-I1-GC
04/21/2022
Filed — Alteration
PROPOSE INTERIOR RENOVATION ON CELLAR, 1ST THRU 3RD FLOOR. PLUMBING & GAS WORKS AS PER PLAN. THIS APPLICATION IS IN CONJUNCTION WITH GC #: Q00702002. NO CHANGE OF USE EGRESS AND OCCUPANCY.
Q00704092-I1
03/29/2022
Objection raised — Admin
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection raised — Inspections
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection raised — Inspections
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection raised — Structural
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection raised — Fire_Protection
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection raised — Fire_Protection
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection raised — Other
03/29/2022
Objection resolved — Addressed
03/22/2022
Filed — Alteration
PROPOSE FILE APPLICATION TO RENOVATION ON CEL, 1ST, 2ND & 3RD FLOOR. FLOORING, CEILING & PARTITIONS WORKS AS PER PLAN. NO CHANGE IN USE, EGRESS, BULK OR OCCUPANCY.
Q00702002-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offWINWAY DEVELOPMENT LLC07/31/2023
DOB NOWPlumbingSigned-offMES CONSTRUCTION CORP05/04/2022
DOB NOWGeneral ConstructionSigned-offWINWAY DEVELOPMENT LLC05/03/2022
1 project · most recent 04/04/2022
General Wiring
FiledStatusContractorScope
04/04/2022CompleteR & T ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/24/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/10/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/05/2022Pass-Final PL - Up to 9 Requested FloorsPassView ↗
10/04/2022Pass-Final General Construction Non-Directive 14PassView ↗
06/24/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/24/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/24/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
07/27/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
07/27/2022Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
07/27/2022Fire-Resistance Rated ConstructionXIUCHENG LIprogress
07/27/2022Energy Code Compliance InspectionsXIUCHENG LIprogress
07/27/2022Interior lighting powerXIUCHENG LIenergy_progress
07/27/2022HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
07/27/2022HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
07/27/2022HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
07/27/2022Air barrier — testing XIUCHENG LIenergy_progress
07/27/2022Fenestration areasXIUCHENG LIenergy_progress
07/27/2022Maintenance informationXIUCHENG LIenergy_progress
07/27/2022Fenestration air leakageXIUCHENG LIenergy_progress
07/27/2022Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/26/2026Q00702002-P1Request digital key ↗
08/26/2026Q00704092-I1Request digital key ↗
08/24/2026Q00895823-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/14/2026Q00702002-I1Open ↗
08/13/2026Q00702002-P1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/26/2026Q00702002-I1Open ↗
08/24/2026Q00895823-I1Open ↗
08/13/2026Q00704092-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q00702002-I1Open ↗
08/26/2026Q00702002-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q00702002-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/24/2026Q00895823-I1Open ↗
08/14/2026Q00702002-I1Open ↗
08/13/2026Q00704092-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026Q00702002-I1Open ↗
08/13/2026Q00704092-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWPL, ST Q00715972, Q00704092 Signoff1
08/13/2026Q00702002-I1Open ↗