← Back
Two family brick
33-60 29 STREET
QUEENS · BIN 4007250
💬 Discuss this project
1950Year Built
2Stories
B1Building Class
R5Zoning
1,624 sfGross Floor Area
2Units
Two family brick · 1,967 sf lot · 0.83 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 211p · 2 filings · 20 docs
Floor 111p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/09/2021$1.1M—Private party → Private party$668/sf building
12/16/2016$1.0M—Private party → Private party$634/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BCHEN ARCHITECT PLLC201/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILD TEAM403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INNOVATIVE VENTURES TEAMGeneral Contractor603/21/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
B CHEN ARCHITECT PLLC1346201/07/2022
Building Lifecycle
All (14)Filed (2)Permit Issued (3)Special Inspection (9)
04/14/2023
Permit issued — Plumbing
Q00625609-I1-PL
01/26/2023
Permit issued — General Construction
Q00622348-I1-MS
01/05/2023
Permit issued — Mechanical Systems
Q00622348-I1-GC
01/07/2022
Filed — Alteration
RENOVATION OF EXISTING 2 FAMILY HOUSE,PLUS CELALR WORK TO INCLUDE.REPLACEMENT OF NEW FIXTURES AND REFINISHING OF WELLS.
Q00622348-I1
01/07/2022
Filed — Alteration
RELOCATE & NEW PLUMBING FIXTURES
Q00625609-I1
11/04/2021
Special inspection requirement — Energy Code Compliance Inspections
billy chen
11/04/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
billy chen
11/04/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
billy chen
11/04/2021
Special inspection requirement — Insulation placement and R values
billy chen
11/04/2021
Special inspection requirement — Interior lighting power
billy chen
11/04/2021
Special inspection requirement — Fenestration air leakage
billy chen
11/04/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
billy chen
11/01/2021
Special inspection requirement — Mechanical Systems
billy chen
11/01/2021
Special inspection requirement — Final
billy chen
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedINFINITI ESC PLUMBING COR04/14/2023
DOB NOWGeneral ConstructionPermit IssuedINNOVATIVE VENTURES TEAM01/26/2023
DOB NOWMechanical SystemsPermit IssuedINNOVATIVE VENTURES TEAM01/05/2023
1 project · most recent 01/07/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
01/07/2022Permit IssuedINNOVATIVE VENTURES TEAMAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MITSUBHI/PEAD-A12AA7 14,000 BTU · Vrf Indoor ×4
PEAD-A18AA7 15,000 BTU · Vrf Indoor ×2
mxz-8c48nahz 48,000 BTU · Condensing Unit ×2
Heating
Mitsubishi Electric mxz-8c48nahz 48,000 BTU · Condensing Unit ×2
1 project · most recent 01/07/2022
Gas Water/Sanitary
FiledStatusContractorScope
01/07/2022Permit IssuedINFINITI ESC PLUMBING CORGas, Water/Sanitary
1 project · most recent 06/20/2023
General Wiring
FiledStatusContractorScope
06/20/2023Permit IssuedPLATINUM PWR ELECTL CONTGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
11/04/2021Energy Code Compliance Inspectionsbilly chenprogress
11/04/2021Fire-Resistant Penetrations and Jointsbilly chenspecial
11/04/2021Fire-Resistant Penetrations and Jointsbilly chenspecial
11/04/2021Insulation placement and R valuesbilly chenenergy_progress
11/04/2021Interior lighting powerbilly chenenergy_progress
11/04/2021Fenestration air leakagebilly chenenergy_progress
11/04/2021Fenestration and door U-factor and product ratingsbilly chenenergy_progress
11/01/2021Mechanical Systemsbilly chenspecial
11/01/2021Finalbilly chenprogress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026Q00622348-I1Request digital key ↗
08/26/2026Q00622348-P1Request digital key ↗
08/26/2026Q00625609-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications22
▸DOB NOWProgress Inspector Seal & Signature12
09/02/2026Q00625609-P1Open ↗
09/01/2026Q00625609-I1Open ↗
08/23/2026Q00622348-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026Q00625609-P1Open ↗
09/01/2026Q00625609-I1Open ↗
08/23/2026Q00622348-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026Q00622348-I1Open ↗
08/26/2026Q00625609-I1Open ↗
08/13/2026Q00622348-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026Q00622348-I1Open ↗
08/26/2026Q00625609-I1Open ↗
08/13/2026Q00622348-P1Open ↗
Showing 3 of 4 on file for this type