← Back
Two family frame
3316 TILDEN AVENUE
BROOKLYN · BIN 3110516
💬 Discuss this project
1910Year Built
2Stories
B2Building Class
R4Zoning
1,752 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family frame · 1,901 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
Architecture
Floor 22p · 1 filing · 11 docs
Floor 12p · 1 filing · 11 docs
Cellar2p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NMI ARCHITECTURE, PLLC212/28/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MIGLIORE RESTORATION203/21/2026
NMI ARCHITECTURE PLLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MIGLIORE RESTORATION INCGeneral Contractor707/08/2026
RIVIERA ELECTRIC CORPElectrical103/22/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NMI ARCHITECTURE, PLLC6825212/28/2021
JUN YAN, PE7170107/08/2021
Building Lifecycle
All (18)Filed (2)Permit Issued (4)Violation (1)Inspection (3)Special Inspection (8)
08/15/2022
Permit issued — General Construction
B00526868-I1-GC
01/24/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/24/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/24/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/07/2022
Permit issued — Plumbing
B00530976-I1-PL
12/28/2021
Filed — Alteration
B00530976-I1
08/10/2021
Permit issued — General Construction
B00526868-I1-GC
07/26/2021
Permit issued — General Construction
B00526868-I1-GC
07/08/2021
Filed — Alteration
B00526868-I1
07/08/2021
Special inspection requirement — Fenestration air leakage
NASHAT IBRAHIM
07/08/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
NASHAT IBRAHIM
07/08/2021
Special inspection requirement — Fenestration areas
NASHAT IBRAHIM
07/08/2021
Special inspection requirement — Insulation placement and R values
NASHAT IBRAHIM
06/18/2021
Special inspection requirement — Energy Code Compliance Inspections
NASHAT IBRAHIM
06/18/2021
Special inspection requirement — Fire-Resistance Rated Construction
NASHAT IBRAHIM
05/21/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
NASHAT IBRAHIM
05/21/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
JUN YAN
04/11/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMIGLIORE RESTORATION INC08/15/2022
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP01/07/2022
DOB NOWGeneral ConstructionPermit IssuedMIGLIORE RESTORATION INC08/10/2021
DOB NOWGeneral ConstructionPermit IssuedMIGLIORE RESTORATION INC07/26/2021
1 project · most recent 10/08/2021
General Wiring
FiledStatusContractorScope
10/08/2021CompleteRIVIERA ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/24/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/24/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/24/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/08/2021Fenestration air leakageNASHAT IBRAHIMenergy_progress
07/08/2021Fenestration and door U-factor and product ratingsNASHAT IBRAHIMenergy_progress
07/08/2021Fenestration areasNASHAT IBRAHIMenergy_progress
07/08/2021Insulation placement and R valuesNASHAT IBRAHIMenergy_progress
06/18/2021Energy Code Compliance InspectionsNASHAT IBRAHIMprogress
06/18/2021Fire-Resistance Rated ConstructionNASHAT IBRAHIMprogress
05/21/2021Fire-Resistant Penetrations and JointsNASHAT IBRAHIMspecial
05/21/2021Structural Stability – Alterations of existing buildingsJUN YANspecial
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/01/2026B00526868-I1Request digital key ↗
08/31/2026B00530976-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature6
08/27/2026B00526868-I1Open ↗
08/27/2026B00526868-I1Open ↗
08/27/2026B00526868-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
09/01/2026B00526868-I1Open ↗
08/31/2026B00530976-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026B00526868-I1Open ↗
08/27/2026B00526868-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/01/2026B00526868-I1Open ↗
08/31/2026B00530976-I1Open ↗