← Back
BuildNYC
Two stories - detached, small or mid-size
332 MARYLAND AVENUE
STATEN ISLAND · BIN 5044105
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R3-2Zoning
2,040 sfGross Floor Area
1Units
1 Active Violation 0 unresolved · 1 paperwork only 1 old, status unconfirmed ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: Saltco · 9,375 sf lot · 0.22 FAR built · Flood zone X
Locations of Work
Plumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 2Plumbing work application6p · 2 filings · 20 docs
Floor 1Plumbing work application6p · 2 filings · 20 docs
CellarPlumbing work application6p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Saltco103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
City Building NY Architect402/09/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
City Building NY Architect603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
V & M Drain CleaningPlumbing207/08/2026
Island Strong ConstrcGeneral Contractor111/24/2020
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A Tech Engineering NYC, P6738112/18/2020
Building Lifecycle
03/27/2025
1RCNY 103-09(e). Failure to file a retaining wall condition assessmentreport by the deadline as required by 1RCNY 103-09(e)(2) and (5). To date,…
ECB violation · open
12/15/2022
Failed to file cycle 1 technical report by 12/31/2018 per rcny 103-09
DOB violation · open · Issued 2022; DOB's record still lists it as active
03/02/2022
Special inspection requirement — HVAC insulation and sealing
anthony santoro
02/09/2022
Filed — Alteration
TO FILE "PL" WORK IN CONJUNCTION WITH ALT-2 JOB#520450770. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S00364101-P2
02/09/2022
Special inspection requirement — HVAC insulation and sealing
anthony santoro
12 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offV & M Drain Cleaning12/29/2021
DOB NOWPlumbingSigned-offV & M Drain Cleaning02/11/2021
BISOTISSUEDIsland Strong Constrc11/24/2020
1 project · most recent 12/18/2020
Ventilation Systems
FiledStatusContractorScope
12/18/2020——Ventilation Systems
1 project · most recent 02/09/2022
Gas Water/Sanitary
FiledStatusContractorScope
02/09/2022Signed-offV & M Drain CleaningGas, Water/Sanitary
1 project · most recent 02/18/2021
General Wiring
FiledStatusContractorScope
02/18/2021Permit IssuedDelta Phase ElectricalGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/02/2022HVAC insulation and sealing anthony santoroenergy_progress
02/09/2022HVAC insulation and sealing anthony santoroenergy_progress
43 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account