← Back
Two stories - detached, small or mid-size
3320 GILES PLACE
BRONX · BIN 2015629
💬 Discuss this project
1910Year Built
2.5Stories
A1Building Class
R4AZoning
2,361 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,364 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
Architecture
Roof2p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/12/2014$475K—Private party → Private party$201/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HENSON ARCHITECTURE PLLC304/15/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
QUINTUNA SERVICE CORPGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CROSSCHECK INSPECTION SER544304/15/2024
HENSON ARCHITECTURE, PLLC973304/15/2024
Building Lifecycle
All (37)Filed (3)Permit Issued (2)Signed Off (1)Objection (10)Special Inspection (21)
05/15/2024
Signed off — Alteration
EXISTING SCREENED-IN PORCH TO BE DEMOLISHED AND NEW SCREENED-IN PORCH TO BE BUILT INCLUDING FLOORING, STRUCTURE, SIDING AND ROOF; NEW FOOTPRINT LARGER THAN EXISTING BY 62 SF. NEW WINDOW OPENING CREATED AT FIRST FLOOR EXTERIOR WALL; NEW WINDOW INSTALLED.
X08008963-I1
05/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Scott Henson
05/01/2024
Special inspection requirement — Vertical Masonry Foundation Elements
EUGENE BIFULCO
05/01/2024
Special inspection requirement — Subgrade Inspections
EUGENE BIFULCO
05/01/2024
Special inspection requirement — Concrete - Cast-In-Place
EUGENE BIFULCO
05/01/2024
Special inspection requirement — Final
Scott Henson
05/01/2024
Special inspection requirement — Fenestration air leakage
Scott Henson
05/01/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Scott Henson
04/15/2024
Filed — Alteration
EXISTING SCREENED-IN PORCH TO BE DEMOLISHED AND NEW SCREENED-IN PORCH TO BE BUILT INCLUDING FLOORING, STRUCTURE, SIDING AND ROOF; NEW FOOTPRINT LARGER THAN EXISTING BY 62 SF. NEW WINDOW OPENING CREATED AT FIRST FLOOR EXTERIOR WALL; NEW WINDOW INSTALLED.
X08008963-P2
04/09/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Scott Henson
04/09/2024
Special inspection requirement — Concrete - Cast-In-Place
EUGENE BIFULCO
04/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Scott Henson
04/09/2024
Special inspection requirement — Subgrade Inspections
EUGENE BIFULCO
04/09/2024
Special inspection requirement — Vertical Masonry Foundation Elements
EUGENE BIFULCO
04/09/2024
Special inspection requirement — Final
Scott Henson
04/09/2024
Special inspection requirement — Fenestration air leakage
Scott Henson
01/02/2024
Permit issued — General Construction
X08008963-I1-GC
07/25/2023
Objection resolved — Addressed
07/21/2023
Objection raised — Other
07/10/2023
Filed — Alteration
EXISTING SCREENED-IN PORCH TO BE DEMOLISHED AND NEW SCREENED-IN PORCH TO BE BUILT INCLUDING FLOORING, STRUCTURE, SIDING AND ROOF; NEW FOOTPRINT LARGER THAN EXISTING BY 62 SF. NEW WINDOW OPENING CREATED AT FIRST FLOOR EXTERIOR WALL; NEW WINDOW INSTALLED.
X08008963-P1
05/30/2023
Special inspection requirement — Concrete - Cast-In-Place
EUGENE BIFULCO
05/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Scott Henson
05/30/2023
Special inspection requirement — Subgrade Inspections
EUGENE BIFULCO
05/30/2023
Special inspection requirement — Vertical Masonry Foundation Elements
EUGENE BIFULCO
05/30/2023
Special inspection requirement — Final
Scott Henson
05/30/2023
Special inspection requirement — Fenestration air leakage
Scott Henson
05/30/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Scott Henson
05/02/2023
Permit issued — General Construction
X08008963-I1-GC
03/07/2023
Objection raised — Other
03/07/2023
Objection resolved — Addressed
11/23/2022
Objection raised — Admin
11/23/2022
Objection resolved — Addressed
11/23/2022
Objection raised — Other
11/23/2022
Objection resolved — Addressed
11/23/2022
Objection raised — Zoning
11/23/2022
Objection resolved — Addressed
11/08/2022
Filed — Alteration
EXISTING SCREENED-IN PORCH TO BE DEMOLISHED AND NEW SCREENED-IN PORCH TO BE BUILT INCLUDING FLOORING, STRUCTURE, SIDING AND ROOF; NEW FOOTPRINT LARGER THAN EXISTING BY 62 SF. NEW WINDOW OPENING CREATED AT FIRST FLOOR EXTERIOR WALL; NEW WINDOW INSTALLED.
X08008963-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offQUINTUNA SERVICE CORP01/02/2024
DOB NOWGeneral ConstructionSigned-offQUINTUNA SERVICE CORP05/02/2023
BISOTISSUEDAMERICAN SOLAR PARTNERS,03/30/2021
2 projects · most recent 08/07/2026
General Wiring
FiledStatusContractorScope
08/07/2026Permit IssuedEMPIRE LIC ELECL CONTRSGeneral Wiring
11/09/2021CompleteHAUGLAND ENERGY GROUP LLC—
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
05/01/2024Fire-Resistant Penetrations and JointsScott Hensonspecial
05/01/2024Vertical Masonry Foundation ElementsEUGENE BIFULCOspecial
05/01/2024Subgrade InspectionsEUGENE BIFULCOspecial
05/01/2024Concrete - Cast-In-PlaceEUGENE BIFULCOspecial
05/01/2024FinalScott Hensonprogress
05/01/2024Fenestration air leakageScott Hensonenergy_progress
05/01/2024Fenestration and door U-factor and product ratingsScott Hensonenergy_progress
04/09/2024Fenestration and door U-factor and product ratingsScott Hensonenergy_progress
04/09/2024Concrete - Cast-In-PlaceEUGENE BIFULCOspecial
04/09/2024Fire-Resistant Penetrations and JointsScott Hensonspecial
04/09/2024Subgrade InspectionsEUGENE BIFULCOspecial
04/09/2024Vertical Masonry Foundation ElementsEUGENE BIFULCOspecial
04/09/2024FinalScott Hensonprogress
04/09/2024Fenestration air leakageScott Hensonenergy_progress
05/30/2023Concrete - Cast-In-PlaceEUGENE BIFULCOspecial
05/30/2023Fire-Resistant Penetrations and JointsScott Hensonspecial
05/30/2023Subgrade InspectionsEUGENE BIFULCOspecial
05/30/2023Vertical Masonry Foundation ElementsEUGENE BIFULCOspecial
05/30/2023FinalScott Hensonprogress
05/30/2023Fenestration air leakageScott Hensonenergy_progress
05/30/2023Fenestration and door U-factor and product ratingsScott Hensonenergy_progress
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026X08008963-P2Request digital key ↗
08/15/2026X08008963-P1Request digital key ↗
08/14/2026X08008963-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
12/23/2019240266270Open ↗
▸BISWORK PERMIT APPLICATION1
03/30/2021240266270Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/15/2026X08008963-P1Open ↗
08/14/2026X08008963-I1Open ↗
08/13/2026X08008963-P2Open ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature9
08/27/2026X08008963-P1Open ↗
08/27/2026X08008963-P1Open ↗
08/27/2026X08008963-P1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/27/2026X08008963-P1Open ↗
08/27/2026X08008963-P1Open ↗
08/25/2026X08008963-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026X08008963-P1Open ↗
08/23/2026X08008963-I1Open ↗
08/13/2026X08008963-P2Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
12/23/2019240266270Open ↗
▸Safety & Tenant Protection2
▸BISTPP1: TENANT PROTECTION PLAN1
03/18/2021240266270Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
12/23/2019240266270Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/23/2019240266270Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026X08008963-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
12/31/2020240266270Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
12/23/2019240266270Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/15/2020240266270Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
12/23/2019240266270Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
12/31/2020240266270Open ↗
12/31/2020240266270Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
12/23/2019240266270Open ↗
▸Other Documents9
▸DOB NOWPlot Diagram3
08/15/2026X08008963-P1Open ↗
08/14/2026X08008963-I1Open ↗
08/13/2026X08008963-P2Open ↗
▸DOB NOWSite Survey: Initial3
08/15/2026X08008963-P1Open ↗
08/14/2026X08008963-I1Open ↗
08/13/2026X08008963-P2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/15/2026X08008963-P1Open ↗
08/14/2026X08008963-I1Open ↗
08/13/2026X08008963-P2Open ↗