Elevator apt, semi-fireproof with stores
333 BEDFORD AVENUE
BROOKLYN · BIN 3335813
💬 Discuss this project
2024Year Built
5Stories
D7Building Class
R6Zoning
10,833 sfGross Floor Area
10Units
Rent Stabilized1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Elevator apt, semi-fireproof with stores · Owner of record: 333 BEDFORD AVE LLC · 2,484 sf lot · 4.36 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalFire Protection
Roof24p · 1 filing · 20 docs
Floor 528p · 1 filing · 20 docs
Floor 425p · 1 filing · 20 docs
Floor 326p · 1 filing · 20 docs
Floor 224p · 1 filing · 20 docs
Floor 126p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SMART CONSULTING NY407/08/2026
SIERRA CONSTRUCTION NY303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/31/2023$3.5M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SYNERGY BUILDING CONSULTANTS403/21/2026
SIERRA SAFETY CORP403/21/2026
SUNSHINE PLAZA LLC1203/21/2026
GREEN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUCCESS DEVELOPERS LLCGeneral Contractor2107/08/2026
CS BRIDGE CORPGeneral Contractor707/08/2026
GWT ENTERPRISES INCGeneral Contractor303/21/2026
CREATIVE PLUMBING INPlumbing107/08/2026
MANHATTAN D ENTERPRISESGeneral Contractor107/08/2026
METFLOW FIRE CONTROL LLCFire Protection107/08/2026
ARIEL SERVICES INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
REGIONAL TESTING CORP.3941206/27/2024
TOHFAZ UDDIN P.E.2001102/29/2024
Building Lifecycle
All (171)Filed (20)Permit Issued (18)Signed Off (14)Violation (2)Inspection (7)Objection (80)Special Inspection (30)
09/17/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/10/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
10/01/2024
Signed off — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-S5
09/12/2024
Signed off — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-S4
09/09/2024
Signed off — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-S1
09/05/2024
Signed off — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-S2
09/05/2024
Signed off — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-S6
08/14/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/25/2024
Objection resolved — Addressed
07/22/2024
Objection raised — Other
07/17/2024
Objection resolved — Addressed
07/17/2024
Objection resolved — Addressed
07/17/2024
Objection resolved — Addressed
07/17/2024
Objection resolved — Addressed
07/17/2024
Objection resolved — Addressed
07/17/2024
Objection resolved — Addressed
07/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
07/17/2024
Special inspection requirement — Sprinkler Systems
Paul Raymond
07/15/2024
Objection resolved — Addressed
07/15/2024
Objection resolved — Addressed
07/15/2024
Special inspection requirement — HVAC-R and service water heating equipment
Paul Raymond
07/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Paul Raymond
07/15/2024
Special inspection requirement — HVAC-R and service water heating system controls
Paul Raymond
07/15/2024
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
07/15/2024
Special inspection requirement — Maintenance information
Paul Raymond
07/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
07/08/2024
Objection resolved — Addressed
07/05/2024
Objection raised — Other
07/05/2024
Objection raised — Scope
06/28/2024
Objection raised — Other
06/28/2024
Objection raised — Other
06/28/2024
Objection raised — Other
06/28/2024
Objection raised — Other
06/28/2024
Objection raised — Other
06/28/2024
Objection raised — Other
06/27/2024
Signed off — Alteration
B01014931-I1
06/27/2024
Signed off — Alteration
Filing for Engineer enclosure system in conjunction with new construction. Filing to comply with 3309.17
B00940681-I1
06/27/2024
Filed — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-P5
06/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
06/27/2024
Special inspection requirement — Sprinkler Systems
Paul Raymond
06/26/2024
Signed off — Alteration
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B01012146-I1
06/26/2024
Filed — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-P3
06/26/2024
Signed off — Alteration
B01012141-I1
06/26/2024
Signed off — Alteration
Proposed construction fence. No change to use, egress or occupancy under this application.
B00882366-I1
06/26/2024
Signed off — Alteration
Installation of temporary overhead protection per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B01012172-I1
06/26/2024
Permit issued — Supported Scaffold
B01014931-I1-SF
06/26/2024
Permit issued — Protection and Mechanical Methods
B00940681-I1-PMM
06/26/2024
Permit issued — Mechanical Systems
B00850624-S4-MS
06/25/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/20/2024
Objection raised — Other
06/10/2024
Filed — New Building
Mechanical work type filed in conjunction with NB#B00850624-I1
B00850624-P4
06/05/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Paul Raymond
06/05/2024
Special inspection requirement — Maintenance information
Paul Raymond
06/05/2024
Special inspection requirement — Fenestration areas
Paul Raymond
06/05/2024
Special inspection requirement — Interior lighting power
Paul Raymond
06/05/2024
Special inspection requirement — Electrical motors and elevators
Paul Raymond
06/05/2024
Special inspection requirement — Protection of exposed foundation insulation
Paul Raymond
06/05/2024
Special inspection requirement — Lighting controls
Paul Raymond
06/05/2024
Special inspection requirement — Metering
Paul Raymond
06/05/2024
Special inspection requirement — Exterior lighting power
Paul Raymond
Latest 60 of 171 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldSigned-offSUCCESS DEVELOPERS LLC06/26/2024
DOB NOWProtection and Mechanical MethodsSigned-offSUCCESS DEVELOPERS LLC06/26/2024
DOB NOWMechanical SystemsSigned-offSUCCESS DEVELOPERS LLC06/26/2024
DOB NOWPlumbingSigned-offDG MECHANICAL HEATING INC04/10/2024
DOB NOWSupported ScaffoldSigned-offCS BRIDGE CORP02/29/2024
DOB NOWProtection and Mechanical MethodsSigned-offCS BRIDGE CORP02/29/2024
DOB NOWProtection and Mechanical MethodsSigned-offCS BRIDGE CORP02/29/2024
DOB NOWSidewalk ShedSigned-offCS BRIDGE CORP02/29/2024
DOB NOWSprinklersSigned-offMETFLOW FIRE CONTROL LLC01/31/2024
DOB NOWPlumbingSigned-offAB PLUMBING INC01/31/2024
DOB NOWSidewalk ShedSigned-offGWT ENTERPRISES INC01/09/2024
DOB NOWStructuralSigned-offSUCCESS DEVELOPERS LLC12/26/2023
DOB NOWFoundationSigned-offSUCCESS DEVELOPERS LLC12/26/2023
DOB NOWSupport of ExcavationSigned-offSUCCESS DEVELOPERS LLC12/26/2023
DOB NOWConstruction FenceSigned-offSUCCESS DEVELOPERS LLC12/14/2023
DOB NOWGeneral ConstructionPermit IssuedSUCCESS DEVELOPERS LLC12/12/2023
DOB NOWSidewalk ShedSigned-offMANHATTAN D ENTERPRISES08/16/2023
DOB NOWConstruction FenceSigned-offSUCCESS DEVELOPERS LLC06/21/2023
BIS—ISSUEDSTAR COMPANIESS LLC11/14/2023
1 project · most recent 06/27/2024
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/27/2024Signed-offSUCCESS DEVELOPERS LLCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin RXSQ24TAVJU 24,000 BTU · Vrf Outdoor ×7
RXTQ36TAVJ9 36,000 BTU · Vrf Outdoor ×5
RK12NMVJU 109,000 BTU · Heat Pump Outdoor ×1
RXTQ48TAVJU 48,000 BTU · Vrf Outdoor ×1
Heating
Daikin RXSQ24TAVJU 27,000 BTU · Vrf Outdoor ×7
RXTQ36TAVJ9 40,000 BTU · Vrf Outdoor ×5
RXTQ48TAVJU 52,000 BTU · Vrf Outdoor ×1
Ventilation
Renewaire EV200 160 CFM · Erv ×1
1 project · most recent 06/27/2024
Sprinkler System
FiledStatusContractorScope
06/27/2024Signed-offMETFLOW FIRE CONTROL LLCSprinkler System
1 project · most recent 06/27/2024
Storm Water/Sanitary
FiledStatusContractorScope
06/27/2024Signed-offDG MECHANICAL HEATING INCStorm, Water/Sanitary
5 projects · most recent 04/11/2024
General Wiring
FiledStatusContractorScope
04/11/2024CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
04/09/2024CompletePOWER DIRECT ELECTRIC INC—
03/28/2024CompletePOWER DIRECT ELECTRIC INC—
02/28/2024CompleteNASH ELECTRIC SERVICES IN—
08/08/2023CompleteSOLAS ELECTRICAL CORP—
1 project · most recent 06/27/2024
Concrete
FiledStatusContractorScope
06/27/2024Signed-offSUCCESS DEVELOPERS LLCConcrete
1 project · most recent 06/27/2024
Earthwork
FiledStatusContractorScope
06/27/2024Signed-offSUCCESS DEVELOPERS LLCEarthwork
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
09/17/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/10/2025Fail-Final CND-Occupancy InspectionFailView ↗
08/14/2024Pass-Final CND-Occupancy InspectionPassView ↗
06/25/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/15/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/27/2024Pass-Final PL - UndergroundPassView ↗
12/26/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 54
DateRequirementInspectorRole
07/17/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
07/17/2024Sprinkler SystemsPaul Raymondspecial
07/15/2024HVAC-R and service water heating equipmentPaul Raymondenergy_progress
07/15/2024HVAC-R and service water piping design and insulationPaul Raymondenergy_progress
07/15/2024HVAC-R and service water heating system controlsPaul Raymondenergy_progress
07/15/2024Energy Code Compliance InspectionsPaul Raymondprogress
07/15/2024Maintenance informationPaul Raymondenergy_progress
07/15/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
06/27/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
06/27/2024Sprinkler SystemsPaul Raymondspecial
06/05/2024Fenestration and door U-factor and product ratingsPaul Raymondenergy_progress
06/05/2024Maintenance informationPaul Raymondenergy_progress
06/05/2024Fenestration areasPaul Raymondenergy_progress
06/05/2024Interior lighting powerPaul Raymondenergy_progress
06/05/2024Electrical motors and elevatorsPaul Raymondenergy_progress
06/05/2024Protection of exposed foundation insulationPaul Raymondenergy_progress
06/05/2024Lighting controlsPaul Raymondenergy_progress
06/05/2024MeteringPaul Raymondenergy_progress
06/05/2024Exterior lighting powerPaul Raymondenergy_progress
06/05/2024Exterior Insulation and Finish Systems (EIFS)Paul Raymondspecial
06/05/2024Fire-Resistant Penetrations and JointsPaul Raymondspecial
06/05/2024Energy Code Compliance InspectionsPaul Raymondprogress
06/05/2024Lighting in dwelling unitsPaul Raymondenergy_progress
06/05/2024Fire-Resistance Rated ConstructionPaul Raymondprogress
06/05/2024Insulation placement and R valuesPaul Raymondenergy_progress
Latest 25 of 54.
▾Documents — 150 on file (BIS + DOB NOW)
▸Plans & Drawings20
▸DOB NOWPlans/Sketch20
08/27/2026B00882366-I1Request digital key ↗
08/27/2026B00850624-S6Request digital key ↗
08/27/2026B00850624-S5Request digital key ↗
Showing 3 of 20 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
11/15/2023340893162Open ↗
11/22/2022322111665Open ↗
▸BISWORK PERMIT APPLICATION1
11/21/2023322111665Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
01/24/2024340893162Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00850624-I1Open ↗
08/13/2026B00850624-P3Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B00850624-P3Open ↗
08/13/2026B00850624-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00850624-I1Open ↗
▸Seals & Professional Certifications77
▸DOB NOWProgress Inspector Seal & Signature33
08/28/2026B00850624-P3Open ↗
08/28/2026B00850624-P3Open ↗
08/28/2026B00850624-P3Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature21
09/01/2026B01012146-I1Open ↗
08/30/2026B00850624-S3Open ↗
08/28/2026B00850624-P5Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature20
08/27/2026B00850624-S4Open ↗
08/27/2026B00850624-P3Open ↗
08/27/2026B00850624-P2Open ↗
Showing 3 of 20 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
07/06/2023340893162Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/06/2023340893162Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
11/22/2022322111665Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B00850624-I1Open ↗
08/13/2026B00850624-P3Open ↗
▸Safety & Tenant Protection10
▸DOB NOWStreet Tree Checklist2
08/15/2026B00850624-I1Open ↗
08/15/2026B00850624-P3Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
11/21/2023322111665Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
01/24/2024340893162Open ↗
▸BISBPP: STREET TREES SITE PLAN1
01/24/2024340893162Open ↗
▸BISSTREET TREE CHECKLIST1
01/24/2024340893162Open ↗
▸BISANTI-HARASSMENT CHECKLIST1
11/21/2023322111665Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00850624-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00850624-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00850624-I1Open ↗
▸Environmental & Asbestos2
▸BISRODENT CONTROL1
11/21/2023322111665Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
11/21/2023322111665Open ↗
▸Energy Compliance2
▸DOB NOWPreliminary Commissioning Report Certification2
08/13/2026B00850624-S5Open ↗
08/13/2026B00850624-S4Open ↗
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT2
08/13/2026B00850624-S2Open ↗
08/13/2026B00850624-P1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00850624-S2Open ↗
▸Approvals, Objections & Sign-offs6
▸BISLETTERS - SUPPORTING DOCUMENTATION5
11/21/2023322111665Open ↗
11/21/2023322111665Open ↗
11/21/2023322111665Open ↗
Showing 3 of 5 on file for this type
▸BISBPP - Forwarding Letter to DEP1
01/24/2024340893162Open ↗
▸Cost, Insurance & Ownership2
▸BISPROJECT-SPECIFIC GL INSURANCE1
11/21/2023322111665Open ↗
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
11/21/2023322111665Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION1
01/24/2024340893162Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
01/24/2024340893162Open ↗
▸BISEFILING COVER SHEET1
11/22/2022322111665Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/06/2023340893162Open ↗
▸Other Documents13
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
01/24/2024340893162Open ↗
11/21/2023322111665Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B00850624-P3Open ↗
08/13/2026B00850624-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00850624-P3Open ↗
08/13/2026B00850624-I1Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026B00850624-S3Open ↗
08/13/2026B00850624-S2Open ↗
▸DOB NOWProperty Ownership Certification2
08/15/2026B00850624-I1Open ↗
08/15/2026B00850624-P3Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
01/24/2024340893162Open ↗
▸BISMICROFILM/RECORDS MGMT: ADDL FEE REQUIRED1
10/07/2024340893162Open ↗
▸DOB NOWFinal Survey1