← Back
BuildNYC
Five to six families
333 MENAHAN STREET
BROOKLYN · BIN 3075761
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6Zoning
4,875 sfGross Floor Area
6Units
Rent Stabilized88 Active Violations 80 unresolved · 8 paperwork only 9 old, status unconfirmed ▸FDNY Report ↗
Five to six families · 2,500 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipmentLandscape
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofProposed Cellar, First, Second Floor Framing12p · 3 filings · 20 docs
Floor 3Proposed Cellar, First, Second Floor Framing10p · 3 filings · 20 docs
Floor 2Proposed Cellar, First, Second Floor Framing10p · 3 filings · 20 docs
Floor 1Installation of Heavy Duty Sidewalk Shed15p · 4 filings · 20 docs
CellarCellar boiler and water heater replacement15p · 4 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M. Hamdi Gunal, PE, P902/08/2023
Syed Engineering111/20/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Expediting103/21/2026
CSR Expediters803/21/2026
Commercial Capital USA203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Zone Plumbing & HeatingPlumbing707/08/2026
H & S Contracting of NYGeneral Contractor403/21/2026
Timothy Coleman LicensedElectrical203/22/2026
Magic ElectricElectrical103/22/2026
JascoScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. Hamdi Gunal, PE3000902/08/2023
Building Lifecycle
09/09/2026
Closed: Failure to certify correction on immediately hazardous (class 1) ECB violation
DOB violation · closed on the city's record
06/12/2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN THE BATHROOM LOCATED AT APT 2R,…
HPD violation · open
06/12/2026
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, WEST AND SOUTH WALLS IN THE BATHROOM LOCATED…
HPD violation · open
06/12/2026
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN THE KITCHEN LOCATED AT APT 2R,…
HPD violation · open
06/12/2026
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd…
HPD violation · open
245 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offZone Plumbing & Heating10/17/2022
DOB NOWSidewalk ShedSigned-offJasco11/30/2021
DOB NOWStructuralSigned-offH & S Contracting of NY08/23/2021
DOB NOWPlumbingSigned-offZone Plumbing & Heating06/30/2021
DOB NOWGeneral ConstructionSigned-offH & S Contracting of NY06/17/2021
4 projects · most recent 09/26/2023
General Wiring
FiledStatusContractorScope
09/26/2023CompleteTimothy Coleman LicensedGeneral Wiring
12/07/2021CompleteRichard Neu—
08/04/2021CompleteMagic ElectricGeneral Wiring
07/12/2021CompleteTimothy Coleman LicensedGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/02/2023Pass-Final Boiler Equipment InspectionPassView ↗
10/20/2022No Access-Final Boiler Equipment InspectionNo AccessView ↗
02/22/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/28/2021Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/28/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/28/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/28/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
02/21/2023Fire-Resistant Penetrations and JointsMehmet Gunalspecial
02/21/2023HVAC-R and service water heating system controlsMehmet Gunalenergy_progress
02/21/2023HVAC-R and service water heating equipmentMehmet Gunalenergy_progress
02/21/2023Maintenance informationMehmet Gunalenergy_progress
02/21/2023HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
12/27/2022Maintenance informationMehmet Gunalenergy_progress
12/27/2022Fire-Resistant Penetrations and JointsMehmet Gunalspecial
12/27/2022HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
12/27/2022HVAC-R and service water heating system controlsMehmet Gunalenergy_progress
12/27/2022HVAC-R and service water heating equipmentMehmet Gunalenergy_progress
11/28/2022HVAC-R and service water heating system controlsMehmet Gunalenergy_progress
11/28/2022Maintenance informationMehmet Gunalenergy_progress
11/28/2022HVAC-R and service water heating equipmentMehmet Gunalenergy_progress
11/28/2022HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
11/28/2022Fire-Resistant Penetrations and JointsMehmet Gunalspecial
08/30/2022Fire-Resistant Penetrations and JointsMehmet Gunalspecial
08/30/2022HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
08/29/2022Fire-Resistant Penetrations and JointsMehmet Gunalspecial
08/29/2022HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
11/18/2021FinalRAFI HAMIDprogress
07/16/2021HVAC-R and service water heating system controlsMehmet Gunalenergy_progress
07/16/2021Maintenance informationMehmet Gunalenergy_progress
07/16/2021HVAC-R and service water piping design and insulationMehmet Gunalenergy_progress
07/16/2021HVAC-R and service water heating equipmentMehmet Gunalenergy_progress
07/16/2021Fire-Resistant Penetrations and JointsMehmet Gunalspecial
Latest 25 of 27.