HPD05/07/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT B17H, 17th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''B''
HPD05/07/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT B17H, 17th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''B''
HPD10/14/2022§ 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL BAGS AND BOXES IN THE ENTIRE APARTMENT LOCATED AT APT B3A, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
ECB07/23/2026Reissue#35693496P exit door not self-closing.exit#9 and stair bulkheadnot closing properly.rem:comply with code.Nothing owed — awaiting certificate of correction
ECB07/23/2026Reissue: 35693497R-failure to maintain building in code-compliant manner. Outside exit #8 is bent and loose due to cars parking illegal and bumping into the rails. Remedy: comply with code.Nothing owed — awaiting certificate of correction
ECB10/03/2025Exit door not self-closing. Noted exterior door at exit #9 and stair abulkhead roof across not self-closing when tested. Remedy: repair/replace door.Nothing owed — awaiting certificate of correction
ECB10/03/2025Reissue #35684839N. Failure to maintain building in code-compliant manner. Noted handrail outside of exit #8 was bent, loose and leaning. Remedy: repair and/or replace.Nothing owed — awaiting certificate of correction
ECB09/16/2024Reissue #35674915R. Failure to maintain building in code-compliant manner. At time of my inspection, i observed the handrail outside exit 8 is loose and chalky near the top weed to make necessary repair or replNothing owed — awaiting certificate of correction
ECB07/07/2023Failure to maintain building in code compliant manner. Noted: the handrail outside exit 8 is loose and shaky near the top. Remedy: repair and/or replace.Nothing owed — awaiting certificate of correction
ECB11/22/2011Failure to maintain building in code compliant manner:(1)west wall water penetration-concrete cracking,exposed rust rebar(2)ceiling cracking, exposed rebar throughout(3) 2 & 3 flr exit doors-hardware not operatNothing owed — awaiting certificate of correction
ECB01/27/2010Failure to file an architect/engineer report certifying exit/directional signs are connected to emergency power source/storage battery equipment.rem:file architect/engineer reportNothing owed — awaiting certificate of correction
ECB01/22/2010Roof access soors have sliding bolt locks which can receive a padlock remedy:remove illegal hardwareNothing owed — awaiting certificate of correction
ECB10/29/2009Failure to maintain bldg walls or appurtenances note : roof of above premises has become porous & is leaking causing damage to the ceiling and walls below in rooms 308 and 371. Remedy: repair leaking roof. MainNothing owed — awaiting certificate of correction
ECB10/23/2009Failure to maintain building in code-compliant manner. Note: at sub-cellar level 1 to 5 various step cracks & vertical cracks in west masonry wall. Concrete ceiling spalling & large pieces missing exposing rebaNothing owed — awaiting certificate of correction
ECB09/25/2007Reissue #34526280L structural vertical & horizontal stress crack throughout interior walls.remedy obtain engineers report for structual stability make all necessary repairsNothing owed — awaiting certificate of correction
ECB05/19/2006Failure to maintain building - interior structural cracking verticle and horizontal causing lateral movement throughout entire building. Reissue#34198578Y,#34282760M.remedy:obtain a structural integrity letter.Nothing owed — awaiting certificate of correction
ECB03/22/2001Failure to maintain: defects are vertical & horizontal stress cracks on corridor walls on all floors. Remedy: make all repairs.Nothing owed — awaiting certificate of correction