3 Active Violations 3 old, status unconfirmed ▸FDNY Report ↗
Two family brick · 2,500 sf lot · 1.49 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofProposed Internal Renovation and Obtain New Certificate of O1p · 1 filing · 17 docs
Floor 2Proposed Internal Renovation and Obtain New Certificate of O5p · 1 filing · 17 docs
Floor 1Proposed Internal Renovation and Obtain New Certificate of O5p · 1 filing · 17 docs
CellarProposed Internal Renovation and Obtain New Certificate of O1p · 1 filing · 17 docs
BasementProposed Internal Renovation and Obtain New Certificate of O5p · 1 filing · 17 docs
Site & exteriorReplacement of collapsed retaining wall7p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
11646 128 St103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/20/2022$450K—Private party → 11646 128 ST CORP$121/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Hansa Building Engineering Services611/17/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Rangasammy Veerapen ConstructionGeneral Contractor903/21/2026
Rangasammy Veerapen ConstructionScaffold303/21/2026
MRC ConstructionGeneral Contractor103/21/2026
Infiniti Esc PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Askon Architect3596511/17/2023
All State Property Inspec4288212/01/2022
Building Lifecycle
04/08/2026
Closed: Failed to file cycle 1 technical report by 12/31/2018 per rcny 103-09
DOB violation · closed on the city's record
02/25/2025
1RCNY 103-09(e). Failure to file a retaining wall condition assessmentreport by the deadline as required by 1RCNY 103-09(e)(2) and (5). To date,…
ECB violation · open
02/07/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
01/09/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Akeeb Shekoni
115 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTumen10/14/2022
DOB NOWGeneral ConstructionPermit IssuedRangasammy Veerapen Construction10/05/2022
DOB NOWConstruction FencePermit IssuedRangasammy Veerapen Construction09/30/2022
DOB NOWPlumbingSigned-offInfiniti Esc Plumbing08/15/2022
DOB NOWGeneral ConstructionPermit IssuedRangasammy Veerapen Construction07/27/2022
BISOTISSUEDMRC Construction03/09/2009
1 project · most recent 11/17/2023
Gas Water/Sanitary
FiledStatusContractorScope
11/17/2023Signed-offInfiniti Esc PlumbingGas, Water/Sanitary
2 projects · most recent 10/29/2023
General Wiring
FiledStatusContractorScope
10/29/2023CompleteN.Z. Pilgrim ElectricGeneral Wiring
05/04/2022CompleteN.Z. Pilgrim ElectricGeneral Wiring
1 project · most recent 12/01/2022
Concrete
FiledStatusContractorScope
12/01/2022Signed-offRangasammy Veerapen ConstructionConcrete
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
02/07/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/16/2022Pass-Final General Construction Non-Directive 14PassView ↗
08/25/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/25/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/25/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/25/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
01/09/2024Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
01/09/2024Structural Stability – Alterations of existing buildingsAkeeb Shekonispecial
01/09/2024Energy Code Compliance InspectionsHANSA PERSAUDprogress
01/09/2024Fire-Resistance Rated ConstructionHANSA PERSAUDprogress
01/09/2024Air barrier - visual inspectionHANSA PERSAUDenergy_progress
01/09/2024Fenestration and door U-factor and product ratingsHANSA PERSAUDenergy_progress
01/09/2024MeteringHANSA PERSAUDenergy_progress
01/09/2024HVAC-R and service water piping design and insulationHANSA PERSAUDenergy_progress
01/09/2024Interior lighting powerHANSA PERSAUDenergy_progress
01/09/2024Fenestration areasHANSA PERSAUDenergy_progress
01/09/2024Fenestration air leakageHANSA PERSAUDenergy_progress
01/09/2024Insulation placement and R valuesHANSA PERSAUDenergy_progress
12/06/2022Subgrade InspectionsAkeeb Shekonispecial
12/06/2022Excavations - Sheeting, Shoring, and BracingAkeeb Shekonispecial
12/06/2022Subsurface Conditions – Fill Placement & In-Place DensitySEBERT DYERspecial
12/06/2022Concrete - Cast-In-PlaceAkeeb Shekonispecial
12/06/2022Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
12/06/2022Structural Stability – Alterations of existing buildingsAkeeb Shekonispecial
12/06/2022FinalHANSA PERSAUDprogress
12/06/2022Footing and FoundationHANSA PERSAUDprogress
11/30/2022Concrete - Cast-In-PlaceAkeeb Shekonispecial
11/30/2022Excavations - Sheeting, Shoring, and BracingAkeeb Shekonispecial
11/30/2022Structural Stability – Alterations of existing buildingsAkeeb Shekonispecial
11/30/2022Subgrade InspectionsAkeeb Shekonispecial
11/30/2022Subsurface Conditions – Fill Placement & In-Place DensitySEBERT DYERspecial
Latest 25 of 28.