← Back
Elevator apt, semi-fireproof with stores
335 BOND STREET
BROOKLYN · BIN 3429743
💬 Discuss this project
2024Year Built
—Stories
D7Building Class
M1-4/R7-2Zoning
96,539 sfGross Floor Area
73Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Elevator apt, semi-fireproof with stores · Owner of record: E & M REALTY CORP. · 15,480 sf lot · 6.24 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction82p · 2 filings · 20 docs
BulkheadUnder Construction2p · 2 filings · 20 docs
Floor 8Under Construction78p · 1 filing · 20 docs
Floor 7Under Construction80p · 1 filing · 20 docs
Floor 6Under Construction83p · 2 filings · 20 docs
Floor 5Under Construction272p · 1 filing · 20 docs
Floor 4Under Construction269p · 1 filing · 20 docs
Floor 3Under Construction264p · 1 filing · 20 docs
Floor 2Under Construction273p · 1 filing · 20 docs
Floor 1Under Construction273p · 1 filing · 20 docs
CellarUnder Construction278p · 3 filings · 20 docs
BasementUnder Construction195p · 2 filings · 20 docs
2 jobs · most recent 07/17/2026
Air Conditioning Systems Others Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/17/2026Permit IssuedTITANIUM CONSTRUCTION SERAir Conditioning Systems, Others
Cooling
Mitsubishi Electric PUMY-P48NKMU 48,000 BTU · Vrf Outdoor ×108
PUMY-P36NKMU 36,000 BTU · Vrf Outdoor ×102
PUMY-P36NKMU3 36,000 BTU · Vrf Outdoor ×18
PUMY-P60NKMU 60,000 BTU · Vrf Outdoor ×15
PUHY-EP120TNU-A 120,000 BTU · Vrf Outdoor ×6
PUHY-EP72TNU-A 72,000 BTU · Vrf Outdoor ×3
PURY-EP16TNU 216,000 BTU · Vrf Outdoor ×3
PURY-EP192TNU 192,000 BTU · Vrf Outdoor ×3
PURY-EP312TSNU 312,000 BTU · Vrf Outdoor ×3
08/02/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PEFY-P48NMAU-E 48,000 BTU · Vrf Indoor ×3
PCFY-P36NKMU-ER1 36,000 BTU · Vrf Indoor ×1
Ventilation
Loren Cook 1650MX 4,200 CFM · Exhaust Fan ×1
HMD-2400 2,400 CFM · Makeup Air ×1
Greenheck RV-25-10 10 tons · Makeup Air ×1
2 jobs · most recent 07/17/2026
Sprinkler System
FiledStatusContractorScope
07/17/2026Permit IssuedFIREQUEST CORPSprinkler System
08/02/2025——66 heads
2 jobs · most recent 07/17/2026
Gas Water/Sanitary Storm
FiledStatusContractorScope
07/17/2026Permit IssuedRITE WAY HEATING CORPGas, Storm, Water/Sanitary
08/02/2025——Gas, Water/Sanitary
7 jobs · most recent 07/29/2024
General Wiring
FiledStatusContractorScope
07/29/2024Permit IssuedPOWER DIRECT ELECTRIC INC—
07/08/2024Permit IssuedPOWER DIRECT ELECTRIC INC—
05/16/2024Permit IssuedV-MAR ELECTRIC LTD.General Wiring
04/13/2024CompleteSOLAS ELECTRICAL CORP—
04/13/2024CompleteSOLAS ELECTRICAL CORP—
10/28/2022CompleteA.L. ELECTRICAL CORP.1 meters, 1 new_meters
05/11/2022CompleteSOLAS ELECTRICAL CORP—
1 job · most recent 07/17/2026
Steel Concrete Masonry
FiledStatusContractorScope
07/17/2026Permit IssuedRITE WAY HEATING CORPSteel, Concrete, Masonry
Building Lifecycle
All (234)Filed (50)Permit Issued (47)Signed Off (15)Violation (7)Inspection (33)Objection (49)Special Inspection (30)Tax Incentive (3)
04/01/2027
421-a(16) construction completed
08/28/2026
Permit issued — Plumbing
B00600073-S4-PL
08/14/2026
Signed off — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-S8
07/17/2026
Filed — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-B2
07/14/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — Maintenance information
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — HVAC-R and service water heating equipment
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — Post-installed Anchors
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
07/14/2026
Special inspection requirement — HVAC-R and service water heating system controls
SAMI HAJJAR P.E
07/06/2026
Filed — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-B1
07/02/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/15/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Fenestration areas
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Vestibules
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Protection of exposed foundation insulation
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Fenestration air leakage
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Exterior lighting power
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Electrical motors and elevators
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Lowest Floor Elevation
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Lighting in dwelling units
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Energy Code Compliance Inspections
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Interior lighting power
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Fire-Resistance Rated Construction
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Insulation placement and R values
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Lighting controls
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Metering
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Air barrier - visual inspection
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Air barrier continuity plan testing
SAMI HAJJAR P.E
06/15/2026
Special inspection requirement — Air barrier — testing
SAMI HAJJAR P.E
06/05/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/29/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
05/12/2026
Signed off — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-S3
05/07/2026
Filed — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-A9
05/01/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/28/2026
Objection resolved — Addressed
04/26/2026
Objection raised — Admin
04/22/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/20/2026
Filed — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-A8
04/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/13/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/31/2026
Objection raised — Admin
03/31/2026
Objection resolved — Addressed
03/30/2026
Filed — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-A7
03/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/23/2026
Special inspection requirement — Interior lighting power
SAMI HAJJAR P.E
03/23/2026
Special inspection requirement — Fenestration areas
SAMI HAJJAR P.E
03/05/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY SUSPENDED SCAFFOLDS PER PLAN SUBMITTED. WORK SHALL COMPLY WITH 2022 BUILDING CODE CHAPTER 33. NO CHANGE IN USE, EGRESS AND/OR OCCUPANCY WITH THIS APPLICATION.
B01182386-I1
03/05/2026
Signed off — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-S2
03/04/2026
Signed off — Alteration
B00721875-I1
02/10/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/05/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PERSONNEL MATERIAL HOIST AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01047127-I1
02/05/2026
Signed off — Alteration
INSTALLATION OF OUTRIGGER PLATFORM IN ACCORDANCE WITH NYCC 2022 CHAPTER 33 BULIDING CODE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01053191-I1
02/03/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE AND SYSTEM SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01063167-I1
01/13/2026
Filed — New Building
Structural work in conjunction with New Building B00600073-I1
B00600073-A6
Latest 60 of 234 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ALBA SERVICES1107/08/2026
OWNERS REP1507/08/2026
DORIA607/08/2026
E M REALTY303/22/2026
TITANIUM CONSTRUCTION SER703/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES2003/21/2026
DVA Advisors1003/21/2026
AE DESIGN SOLUTION1603/21/2026
PATUXENT ENGINEERING203/21/2026
KD DESIGNS403/21/2026
EUROCELT EXPEDITING, INC203/21/2026
HOWARD I SHAPIRO ASSOCIATES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TITANIUM CONSTRUCTION SERGeneral Contractor2807/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor807/08/2026
FIREQUEST CORPFire Protection607/08/2026
RITE WAY HEATING CORPPlumbing308/30/2026
STARLITE PLBG & HTG CORPPlumbing207/08/2026
DORIA SCAFFOLDING LLCGeneral Contractor107/08/2026
RYBAK DEVELOPMENT AND CONSTRUCTGeneral Contractor104/09/2026
CONSOLIDATED SCAFFOLDINGGeneral Contractor104/09/2026
WINDHAM RESTORATION CORPGeneral Contractor104/09/2026
PLUMBING NYC INCPlumbing107/08/2026
CANDID CONNECTION INCGeneral Contractor104/09/2026
ALBA SERVICES INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
METRIC CONSULTING AND INS18033107/17/2026
SKYLINE RIGGING7880103/06/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedRITE WAY HEATING CORP08/28/2026
DOB NOWGeneral ConstructionPermit IssuedTITANIUM CONSTRUCTION SER12/26/2025
DOB NOWMechanical SystemsSigned-offTITANIUM CONSTRUCTION SER10/17/2025
DOB NOWConstruction FenceSigned-offTITANIUM CONSTRUCTION SER09/26/2025
DOB NOWPlumbingPermit IssuedLS PLUMBING CORP09/03/2025
DOB NOWSuspended ScaffoldPermit IssuedDORIA SCAFFOLDING06/10/2025
DOB NOWProtection and Mechanical MethodsSigned-offTITANIUM CONSTRUCTION SER06/09/2025
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC05/30/2025
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC04/25/2025
DOB NOWSuspended ScaffoldPermit IssuedWINDHAM RESTORATION CORP04/01/2025
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC03/11/2025
DOB NOWSuspended ScaffoldPermit IssuedDORIA, INC03/06/2025
DOB NOWStructuralSigned-offTITANIUM CONSTRUCTION SER01/07/2025
DOB NOWGeneral ConstructionPermit IssuedTITANIUM CONSTRUCTION SER01/06/2025
DOB NOWStandpipePermit IssuedFIREQUEST CORP10/11/2024
DOB NOWStandpipeSigned-offFIREQUEST CORP10/11/2024
DOB NOWSprinklersPermit IssuedFIREQUEST CORP10/11/2024
DOB NOWMechanical SystemsSigned-offTITANIUM CONSTRUCTION SER10/02/2024
DOB NOWConstruction FenceSigned-offTITANIUM CONSTRUCTION SER10/02/2024
DOB NOWSupport of ExcavationSigned-offTITANIUM CONSTRUCTION SER10/02/2024
DOB NOWPlumbingPermit IssuedLS PLUMBING CORP09/18/2024
DOB NOWFoundationSigned-offTITANIUM CONSTRUCTION SER09/05/2024
DOB NOWPlumbingPermit IssuedSTARLITE PLBG & HTG CORP08/30/2024
DOB NOWProtection and Mechanical MethodsSigned-offTITANIUM CONSTRUCTION SER07/09/2024
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC06/11/2024
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC05/08/2024
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC03/13/2024
DOB NOWStandpipeSigned-offFIREQUEST CORP03/11/2024
DOB NOWStandpipePermit IssuedFIREQUEST CORP03/08/2024
DOB NOWStandpipePermit IssuedFIREQUEST CORP03/08/2024
DOB NOWPlumbingPermit IssuedSTARLITE PLBG & HTG CORP02/12/2024
DOB NOWStructuralSigned-offTITANIUM CONSTRUCTION SER02/06/2024
DOB NOWGeneral ConstructionPermit IssuedTITANIUM CONSTRUCTION SER01/23/2024
DOB NOWGeneral ConstructionPermit IssuedTITANIUM CONSTRUCTION SER10/23/2023
DOB NOWConstruction FenceSigned-offTITANIUM CONSTRUCTION SER10/05/2023
DOB NOWFoundationSigned-offTITANIUM CONSTRUCTION SER10/05/2023
DOB NOWSupport of ExcavationSigned-offTITANIUM CONSTRUCTION SER10/02/2023
DOB NOWMechanical SystemsSigned-offTITANIUM CONSTRUCTION SER10/02/2023
DOB NOWFoundationSigned-offTITANIUM CONSTRUCTION SER09/27/2023
DOB NOWStandpipeSigned-offPLUMBING WORKS NYC INC09/14/2023
+ 7 more permits on file
▾Field Inspections (DOB CAP) — 34
DateTypeResultReport
07/02/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/05/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/29/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
05/01/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/22/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/10/2026Pass-Final CND-Occupancy InspectionPassView ↗
11/24/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/24/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/27/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/08/2025Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
10/08/2025Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
09/25/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/16/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/11/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/11/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
04/16/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
04/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/19/2024Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
08/19/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)CertifiedView ↗
07/24/2024Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
07/24/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
Latest 25 of 34.
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
07/14/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSAMI HAJJAR P.Especial
07/14/2026HVAC-R and service water piping design and insulationSAMI HAJJAR P.Eenergy_progress
07/14/2026HVAC-R and service water heating equipmentSAMI HAJJAR P.Eenergy_progress
07/14/2026Maintenance informationSAMI HAJJAR P.Eenergy_progress
07/14/2026HVAC-R and service water heating system controlsSAMI HAJJAR P.Eenergy_progress
07/14/2026Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
07/14/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)SAMI HAJJAR P.Especial
07/14/2026Post-installed AnchorsSAMI HAJJAR P.Especial
06/15/2026Lowest Floor ElevationSAMI HAJJAR P.Eprogress
06/15/2026Fire-Resistance Rated ConstructionSAMI HAJJAR P.Eprogress
06/15/2026Energy Code Compliance InspectionsSAMI HAJJAR P.Eprogress
06/15/2026Wall Panels, Curtain Walls, and VeneersSAMI HAJJAR P.Especial
06/15/2026Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
06/15/2026Fenestration and door U-factor and product ratingsSAMI HAJJAR P.Eenergy_progress
06/15/2026Fenestration air leakageSAMI HAJJAR P.Eenergy_progress
06/15/2026Protection of exposed foundation insulationSAMI HAJJAR P.Eenergy_progress
06/15/2026Air barrier - visual inspectionSAMI HAJJAR P.Eenergy_progress
06/15/2026Air barrier — testing SAMI HAJJAR P.Eenergy_progress
06/15/2026Air barrier continuity plan testingSAMI HAJJAR P.Eenergy_progress
06/15/2026VestibulesSAMI HAJJAR P.Eenergy_progress
06/15/2026Exterior lighting powerSAMI HAJJAR P.Eenergy_progress
06/15/2026MeteringSAMI HAJJAR P.Eenergy_progress
06/15/2026Fenestration areasSAMI HAJJAR P.Eenergy_progress
06/15/2026Lighting controlsSAMI HAJJAR P.Eenergy_progress
06/15/2026Insulation placement and R valuesSAMI HAJJAR P.Eenergy_progress
Latest 25 of 150.
▾Documents — 364 on file (BIS + DOB NOW)
▸Plans & Drawings54
▸DOB NOWPlans/Sketch53
08/31/2026B00600073-B3Contact architect ↗
08/31/2026B00667705-P1Contact architect ↗
08/31/2026B00667705-I1Contact architect ↗
Showing 3 of 53 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
02/08/2024340835172Open ↗
02/06/2024340835172Open ↗
05/31/2023340835172Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHPD - Permit Notice2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISBPP-DOT: SIDEWALK/CURB/ROAD WORK PERMITS1
10/23/2023340835172Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
05/04/2022340835172Open ↗
▸Zoning, Tax Lot & Property Records41
▸DOB NOWRestrictive Declaration/Easement 116
08/31/2026B00600073-B3Open ↗
08/17/2026B00600073-S3Open ↗
08/17/2026B00600073-B2Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸DOB NOWZoning Exhibit form (1-5)10
08/17/2026B00600073-A7Open ↗
08/17/2026B00600073-A9Open ↗
08/17/2026B00600073-B1Open ↗
Showing 3 of 10 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
07/21/2025321602208Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
07/21/2025321602208Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
07/21/2025321602208Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
07/21/2025321602208Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications129
▸DOB NOWDPL-1: Design Professional Seal & Signature55
09/03/2026B00733718-I1Open ↗
08/31/2026B00600073-B3Open ↗
08/31/2026B00667705-I1Open ↗
Showing 3 of 55 on file for this type
▸DOB NOWProgress Inspector Seal & Signature37
09/01/2026B00600073-S2Open ↗
08/31/2026B00600073-B2Open ↗
08/30/2026B00600073-A1Open ↗
Showing 3 of 37 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature35
09/01/2026B00600073-S2Open ↗
08/31/2026B00600073-B2Open ↗
08/31/2026B00600073-B2Open ↗
Showing 3 of 35 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/04/2022340835172Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
05/04/2022340835172Open ↗
▸Trade Schedules & Equipment9
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)8
08/17/2026B00600073-A7Open ↗
Showing 1 of 8 on file for this type
▸DOB NOWStandpipe Alarms Drawings1
08/17/2026B00600073-I1—
▸Safety & Tenant Protection12
▸DOB NOWStreet Tree Checklist10
08/17/2026B00600073-I1Open ↗
08/17/2026B00600073-B1Open ↗
08/17/2026B00600073-A9Open ↗
Showing 3 of 10 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
10/23/2023340835172Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos54
▸DOB NOWOER: Notice to Proceed34
08/31/2026B00600073-B3Open ↗
08/31/2026B00600073-S4Open ↗
08/17/2026B00600073-B1Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWOER: Notice of Satisfaction17
08/17/2026B00600073-S3Open ↗
Showing 1 of 17 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/31/2026B00667705-P1Open ↗
08/31/2026B00667705-I1Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
10/23/2023340835172Open ↗
▸Inspections & Test Reports8
▸DOB NOWSOIL REPORT3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWTR5 Test Report3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Approvals, Objections & Sign-offs1
▸BISNYS DEC TIDAL WETLANDS APPROVAL1
05/04/2022340835172Open ↗
▸Filing & Intake Forms2
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
05/04/2022340835172Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
05/04/2022340835172Open ↗
▸Other Documents46
▸DOB NOWSite Survey: Initial10
08/17/2026B00600073-B1Open ↗
08/17/2026B00600073-A9Open ↗
08/17/2026B00600073-A7Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone10
08/17/2026B00600073-B1Open ↗
08/17/2026B00600073-A9Open ↗
08/17/2026B00600073-A7Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProperty Ownership Certification10
08/17/2026B00600073-I1Open ↗
08/17/2026B00600073-B1Open ↗
08/17/2026B00600073-A9Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
10/23/2023340835172Open ↗
05/04/2022340835172Open ↗
▸BISNYS DEC TIDAL WETLANDS MAP1
05/04/2022340835172Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
07/21/2025321602208Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWAdjoining Owners Notification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWManufacturer's Specifications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWCalculations1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWTR5H Test Report1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type