← Back
Walk-up cooperative
336 EAST 77 STREET
💬 Discuss this project
1910Year Built
5Stories
C6Building Class
R8BZoning
10,060 sfGross Floor Area
19Units
Rent Stabilized2 Open Violations ▸
Walk-up cooperative · Owner of record: 332-336 EAST 77TH STREET ASSOC · 2,554 sf lot · 3.94 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneralOther
Floor 115p · 1 filing · 20 docs
Cellar8p · 1 filing · 20 docs
Site & exterior7p · 1 filing · 20 docs
Filed — no permit issued6p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KENILWORTH EQUITIES303/21/2026
PHOENIX BRIDGING INC DBA PHOENIX203/21/2026
C/O KENILWORTH EQUITIES203/21/2026
332-336 EAST 77TH STREET ASSOC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AB ARCHITEKTEN205/19/2026
PE AND CONSULTANTS NY LLC105/11/2026
EP ENGINEERING LLC301/29/2026
OUT OF SHAPE ARCHITECTURE, PLLC305/12/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
3A CONTRACTING CORPGeneral Contractor207/08/2026
MEGA MECHANICAL INCGeneral Contractor104/09/2026
TAP PLUMBING CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EP INSPECTIONS AND COMMIS7079201/29/2026
Building Lifecycle
All (95)Filed (8)Permit Issued (4)Signed Off (2)Violation (21)Inspection (2)Objection (28)Special Inspection (30)
08/24/2026
Objection resolved — Addressed
08/12/2026
Objection resolved — Addressed
08/12/2026
Objection resolved — Addressed
08/12/2026
Objection resolved — Addressed
07/23/2026
Objection resolved — Addressed
07/23/2026
Objection resolved — Addressed
07/23/2026
Objection resolved — Addressed
07/23/2026
Objection resolved — Addressed
07/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
07/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
07/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
07/21/2026
Special inspection requirement — Insulation placement and R values
07/21/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
07/21/2026
Special inspection requirement — Energy Code Compliance Inspections
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/12/2026
Objection resolved — Resolved
06/07/2026
Objection raised — Scope
06/07/2026
Objection raised — Inspections
06/07/2026
Objection raised — Energy
06/07/2026
Objection raised — Zoning
06/02/2026
Objection raised — Energy
06/02/2026
Objection raised — Fire_Protection
06/02/2026
Objection raised — Energy
06/02/2026
Objection raised — Zoning
06/02/2026
Objection raised — Cost
06/02/2026
Objection raised — Inspections
06/02/2026
Objection raised — Cost
06/02/2026
Objection raised — Structural
06/02/2026
Objection raised — Inspections
05/19/2026
Filed — Alteration
REINFORCE ROOF JOISTS BY SISTERING NEW JOISTS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01384973-S1
05/11/2026
Filed — Alteration
REINFORCE ROOF JOISTS BY SISTERING NEW JOISTS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01384973-S2
05/07/2026
Filed — Alteration
REINFORCE ROOF JOISTS BY SISTERING NEW JOISTS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01384973-I1
05/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/29/2026
Violation issued (HPD, closed)
A
04/09/2026
Special inspection requirement — Mechanical Systems
04/09/2026
Special inspection requirement — Final
04/09/2026
Special inspection requirement — Final
02/02/2026
Signed off — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL UNIT APT#3 IN A MULTI-FAMILY STRUCTURE. KITCHEN TO BE RELOCATED INSIDE OF UNIT; NO CHANGE TO USE OR EGRESS.
M01147576-S3
02/02/2026
Special inspection requirement — Duct leakage testing, insulation and design
MOLLY GLENN
02/02/2026
Special inspection requirement — Mechanical Systems
MOLLY GLENN
02/02/2026
Special inspection requirement — Energy Code Compliance Inspections
MOLLY GLENN
02/02/2026
Special inspection requirement — Final
MOLLY GLENN
02/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
MOLLY GLENN
02/02/2026
Special inspection requirement — Maintenance information
MOLLY GLENN
02/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
MOLLY GLENN
02/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
MOLLY GLENN
01/29/2026
Signed off — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL UNIT APT#3 IN A MULTI-FAMILY STRUCTURE. KITCHEN TO BE RELOCATED INSIDE OF UNIT; NO CHANGE TO USE OR EGRESS.
M01147576-I1
01/29/2026
Filed — Alteration
RENOVATION OF AN EXISTING RESIDENTIAL UNIT APT#3 IN A MULTI-FAMILY STRUCTURE. KITCHEN TO BE RELOCATED INSIDE OF UNIT; NO CHANGE TO USE OR EGRESS.
M01147576-P2
01/26/2026
Special inspection requirement — Duct leakage testing, insulation and design
MOLLY GLENN
01/26/2026
Special inspection requirement — Mechanical Systems
MOLLY GLENN
01/26/2026
Special inspection requirement — Energy Code Compliance Inspections
MOLLY GLENN
01/26/2026
Special inspection requirement — Final
MOLLY GLENN
01/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
MOLLY GLENN
01/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
MOLLY GLENN
01/26/2026
Special inspection requirement — Maintenance information
MOLLY GLENN
01/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
MOLLY GLENN
Latest 60 of 95 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-off3A CONTRACTING CORP10/03/2025
DOB NOWMechanical SystemsSigned-offMEGA MECHANICAL INC05/28/2025
DOB NOWPlumbingPermit IssuedTAP PLUMBING CORP04/07/2025
DOB NOWGeneral ConstructionSigned-off3A CONTRACTING CORP04/01/2025
BISEQISSUEDPHOENIX SUTTON STR INC02/26/2013
BISPLISSUEDPAT SEMENTA P & H CO INC02/16/2007
BISOTISSUEDFRANK BASILE CONTRACTING02/12/2007
2 projects · most recent 05/19/2026
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/19/2026——Air Conditioning Systems
Cooling
Mitsubishi Electric MSZ - GX9NL 12,200 BTU · Ahu ×1
MSZ-GX12NL 14,000 BTU · Ahu ×1
MXZ-2D2ONL 20,000 BTU · Condensing Unit ×1
01/29/2026Signed-off3A CONTRACTING CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric TRUZA0181KA70NA 18,000 BTU · Condensing Unit ×1
PUZ-A18NKA7 22,000 BTU · Split System ×2
Ventilation
Neptronic CMU06B010AD 60 CFM · Makeup Air ×3
1 project · most recent 01/29/2026
Water/Sanitary
FiledStatusContractorScope
01/29/2026Permit IssuedTAP PLUMBING CORPWater/Sanitary
1 project · most recent 05/19/2026
Wood
FiledStatusContractorScope
05/19/2026——Wood
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
10/03/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/30/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 42
DateRequirementInspectorRole
07/23/2026HVAC-R and service water heating system controls—energy_progress
07/23/2026HVAC-R and service water heating equipment—energy_progress
07/23/2026HVAC-R and service water piping design and insulation—energy_progress
07/21/2026Insulation placement and R values—energy_progress
07/21/2026Fenestration and door U-factor and product ratings—energy_progress
07/21/2026Energy Code Compliance Inspections—progress
05/06/2026Tenant Protection Plan Compliance—special
05/06/2026Tenant Protection Plan Compliance—special
04/09/2026Mechanical Systems—special
04/09/2026Final—progress
04/09/2026Final—progress
02/02/2026Duct leakage testing, insulation and designMOLLY GLENNenergy_progress
02/02/2026Mechanical SystemsMOLLY GLENNspecial
02/02/2026Energy Code Compliance InspectionsMOLLY GLENNprogress
02/02/2026FinalMOLLY GLENNprogress
02/02/2026HVAC-R and service water heating equipmentMOLLY GLENNenergy_progress
02/02/2026Maintenance informationMOLLY GLENNenergy_progress
02/02/2026HVAC-R and service water heating system controlsMOLLY GLENNenergy_progress
02/02/2026HVAC-R and service water piping design and insulationMOLLY GLENNenergy_progress
01/26/2026Duct leakage testing, insulation and designMOLLY GLENNenergy_progress
01/26/2026Mechanical SystemsMOLLY GLENNspecial
01/26/2026Energy Code Compliance InspectionsMOLLY GLENNprogress
01/26/2026FinalMOLLY GLENNprogress
01/26/2026HVAC-R and service water piping design and insulationMOLLY GLENNenergy_progress
01/26/2026HVAC-R and service water heating system controlsMOLLY GLENNenergy_progress
Latest 25 of 42.
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/25/2026M01147576-S3Request digital key ↗
08/25/2026M01147576-S2Request digital key ↗
08/25/2026M01147576-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
03/04/2013121545765Open ↗
▸BISWORK PERMIT APPLICATION1
03/04/2013121545765Open ↗
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature11
08/29/2026M01147576-I1Open ↗
08/29/2026M01147576-I1Open ↗
08/29/2026M01147576-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/25/2026M01147576-P2Open ↗
08/25/2026M01147576-S3Open ↗
08/25/2026M01147576-S1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
09/20/2013121545765Open ↗
09/20/2013121545765Open ↗
03/04/2013121545765Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026M01147576-S3Open ↗
08/26/2026M01147576-P2Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/04/2013121545765Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
03/04/2013121545765Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/25/2026M01147576-S3Open ↗
08/25/2026M01147576-S2Open ↗
08/25/2026M01147576-S1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/04/2013121545765Open ↗
▸Approvals, Objections & Sign-offs3
▸BISLETTERS - SUPPORTING DOCUMENTATION1
09/20/2013121545765Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/20/2013121545765Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/04/2013121545765Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/04/2013121545765Open ↗