← Back
Two family brick
338 94 STREET
BROOKLYN · BIN 3155482
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R5BZoning
2,280 sfGross Floor Area
2Units
Two family brick · 2,483 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 13 docs
Floor 11p · 1 filing · 13 docs
Cellar3p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/23/2021$1.3M—— → —$583/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J&R DESIGN AND INSPECTION CORP.209/17/2021
CL ENGINEERING P.C.207/13/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MES CONSTRUCTION CORPPlumbing707/08/2026
KJK ELECTRIC INCElectrical203/21/2026
ZHENG LIElectrical203/21/2026
HIGH QUALITY CONSTRUCTIONGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637409/17/2021
Building Lifecycle
All (23)Filed (4)Permit Issued (2)Signed Off (2)Inspection (5)Special Inspection (10)
10/13/2021
Signed off — Alteration
PLUMBING WORK IS FILED TO CONJUNCTION WITH DOB NOW JOB #B00518589. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00522776-I1
10/07/2021
Signed off — Alteration
GENERAL RENOVATION OF 2-FAMILY HOUSE WITH REMOVING PARTITION, REPAIRING EXISTING FLOOR, CEILING, NEW PARTITION AND PAINTING WORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00518589-I1
09/29/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/22/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/17/2021
Filed — Alteration
PLUMBING WORK IS FILED TO CONJUNCTION WITH DOB NOW JOB #B00518589. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00522776-P2
09/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
09/17/2021
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
09/17/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
09/17/2021
Special inspection requirement — Maintenance information
Robert Truskosky
09/17/2021
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
09/17/2021
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
07/22/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/22/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/22/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/13/2021
Filed — Alteration
PLUMBING WORK IS FILED TO CONJUNCTION WITH DOB NOW JOB #B00518589. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00522776-P1
05/25/2021
Permit issued — Plumbing
B00522776-I1-PL
05/19/2021
Permit issued — General Construction
B00518589-I1-GC
05/17/2021
Filed — Alteration
PLUMBING WORK IS FILED TO CONJUNCTION WITH DOB NOW JOB #B00518589. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00522776-I1
05/17/2021
Filed — Alteration
GENERAL RENOVATION OF 2-FAMILY HOUSE WITH REMOVING PARTITION, REPAIRING EXISTING FLOOR, CEILING, NEW PARTITION AND PAINTING WORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00518589-I1
05/14/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
05/14/2021
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
05/14/2021
Special inspection requirement — Fire-Resistance Rated Construction
Robert Truskosky
05/07/2021
Special inspection requirement — Final
Robert Truskosky
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offMES CONSTRUCTION CORP05/25/2021
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION05/19/2021
2 projects · most recent 08/23/2021
General Wiring
FiledStatusContractorScope
08/23/2021CompleteKJK ELECTRIC INC3 meters, 3 new_meters
05/20/2021CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/29/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/22/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/22/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/22/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/22/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/17/2021Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
09/17/2021Energy Code Compliance InspectionsRobert Truskoskyprogress
09/17/2021HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
09/17/2021Maintenance informationRobert Truskoskyenergy_progress
09/17/2021HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
09/17/2021HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
05/14/2021Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
05/14/2021Energy Code Compliance InspectionsRobert Truskoskyprogress
05/14/2021Fire-Resistance Rated ConstructionRobert Truskoskyprogress
05/07/2021FinalRobert Truskoskyprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/01/2026B00518589-I1Request digital key ↗
09/01/2026B00522776-P2Request digital key ↗
09/01/2026B00522776-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00518589-I1Open ↗
09/01/2026B00522776-P2Open ↗
09/01/2026B00522776-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026B00518589-I1Open ↗
08/26/2026B00522776-P2Open ↗
08/26/2026B00522776-P2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026B00518589-I1Open ↗
08/26/2026B00522776-P2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/01/2026B00518589-I1Open ↗
09/01/2026B00522776-P2Open ↗
09/01/2026B00522776-P1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00522776-I1Open ↗