| Owner | Filings | Most Recent |
|---|---|---|
| UNITED DEVELOPERS | 23 | 04/09/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/23/2024 | $855K | — | YOU CANT HANDLE US RE LLC → EAST 234 PARTNERS LLC | $358/sf building |
| 04/18/2024 | $420K | — | Private party → YOU CAN'T HANDLE US RE, LLC | $176/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| PIROOZ ENGINEERING, P.C. | 7 | 11/14/2025 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| PRECISION HOME DEV INC | General Contractor | 5 | 04/09/2026 |
| GO PRO FIRE PROTECTION C | Fire Protection | 1 | 07/08/2026 |
| INFINITI ESC PLUMBING COR | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| PIROOZ ENGINEERING P.C | 7177 | 5 | 11/14/2025 |
| IP CONCRETE TESTING AND I | 6252 | 1 | 07/29/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Signed-off | GO PRO FIRE PROTECTION C | 08/28/2025 |
| DOB NOW | Plumbing | Signed-off | INFINITI ESC PLUMBING COR | 08/05/2025 |
| DOB NOW | Earth Work | Permit Issued | PRECISION HOME DEV INC | 07/30/2025 |
| DOB NOW | Curb Cut | Signed-off | PRECISION HOME DEV INC | 07/28/2025 |
| DOB NOW | Construction Fence | Signed-off | PRECISION HOME DEV INC | 07/28/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 11/14/2025 | Permit Issued | PRECISION HOME DEV INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool York OUTDOOR UNITS - HH836E2S11
INDOOR UNITS AT ATTIC & CELLAR - JHE36C5CD2SS1 48,000 BTU ×4 Mitsubishi Electric CU-1: MXZ-SM48NAMHZ
AH1, AH-2 & AH-3: MSZ-GS09
AH-4: MSZ-GS12 48,000 BTU · Vrf Outdoor ×2 Ventilation |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2025 | Signed-off | GO PRO FIRE PROTECTION C | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2025 | Signed-off | INFINITI ESC PLUMBING COR | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/31/2025 | Complete | SKY ELECTRIC LLC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2025 | Signed-off | GO PRO FIRE PROTECTION C | Concrete, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2025 | Signed-off | GO PRO FIRE PROTECTION C | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2025 | Signed-off | GO PRO FIRE PROTECTION C | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/14/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 12/09/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 12/04/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 11/24/2025 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 08/29/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 08/29/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/29/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/29/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/15/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/24/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/28/2025 | Masonry | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Excavations - Sheeting, Shoring, and Bracing | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Subgrade Inspections | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Concrete - Cast-In-Place | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Subsurface Investigations (Borings/Test Pits) | INDARDEO PARBHUNATH | special |
| 11/28/2025 | Mechanical Systems | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Fire-Resistant Penetrations and Joints | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Interior lighting power | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | HVAC-R and service water heating equipment | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Fenestration and door U-factor and product ratings | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | HVAC-R and service water heating system controls | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Metering | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Heating Systems | PIROOZ SOLTANIZADEH | special |
| 11/28/2025 | Structural Wood Frame | PIROOZ SOLTANIZADEH | progress |
| 11/28/2025 | Final | NAVEEN KUMAR | progress |
| 11/28/2025 | Energy Code Compliance Inspections | PIROOZ SOLTANIZADEH | progress |
| 11/28/2025 | Fire-Resistance Rated Construction | PIROOZ SOLTANIZADEH | progress |
| 11/28/2025 | Preliminary | PIROOZ SOLTANIZADEH | progress |
| 11/28/2025 | Footing and Foundation | PIROOZ SOLTANIZADEH | progress |
| 11/28/2025 | Permanent certificate | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Air barrier — testing | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Fenestration air leakage | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | HVAC-R and service water piping design and insulation | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Maintenance information | PIROOZ SOLTANIZADEH | energy_progress |
| 11/28/2025 | Electric vehicle service equipment requirements | PIROOZ SOLTANIZADEH | energy_progress |