← Back
Three families
34-22 29 STREET
QUEENS · Astoria (Central) · BIN 4007320
💬 Discuss this project
1945Year Built
2Stories
C0Building Class
R5Zoning
3,796 sfGross Floor Area
3Units
Rent Stabilized7 Open Violations ▸FDNY Report ↗
Three families · 2,521 sf lot · 1.51 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 21p · 1 filing · 10 docs
Floor 12p · 2 filings · 16 docs
Basement6p · 2 filings · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/16/2022$1.7M—Private party → Private party$453/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
G ENGINEERING PC607/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEWGRANGE ELECTRIC, INCElectrical103/22/2026
TT&T CONSTRUCTION INCGeneral Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
G ENGINEERING PC7778307/17/2023
Building Lifecycle
All (31)Filed (6)Permit Issued (2)Signed Off (2)Violation (10)Inspection (5)Special Inspection (6)
05/06/2026
Violation issued (HPD, open)
A
11/21/2025
Violation issued (HPD, open)
I
06/11/2025
Violation issued (HPD, open)
A
12/02/2024
Violation issued (HPD, open)
I
04/12/2024
Violation issued (HPD, open)
A
11/24/2023
Violation issued (HPD, open)
I
10/18/2023
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049878-I1
10/11/2023
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049874-I1
10/06/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/21/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/24/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
07/19/2023
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
07/19/2023
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
07/17/2023
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049874-P2
07/17/2023
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049878-P2
06/02/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/02/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/25/2023
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049874-P1
05/25/2023
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049878-P1
05/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
05/25/2023
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
05/25/2023
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
03/27/2023
Violation issued (HPD, open)
A
12/20/2022
Permit issued — Plumbing
Q08049878-I1-PL
12/12/2022
Permit issued — General Construction
Q08049874-I1-GC
12/06/2022
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW BOILER AND HOT WATER HEATER ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049878-I1
12/06/2022
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q08049874-I1
11/15/2022
Violation issued (HPD, closed)
I
03/03/2022
Violation issued (HPD, closed)
A
04/14/2021
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC12/20/2022
DOB NOWGeneral ConstructionSigned-offTT&T CONSTRUCTION INC12/12/2022
BISOTISSUEDACCORD POWER INC07/13/2023
1 project · most recent 07/11/2023
FiledStatusContractorScope
07/11/2023CompleteNEWGRANGE ELECTRIC, INC—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/06/2023Pass-Final General Construction Non-Directive 14PassView ↗
09/21/2023Fail-Final General Construction Non-Directive 14FailView ↗
07/24/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/02/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/02/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
07/19/2023Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
07/19/2023Energy Code Compliance InspectionsXIONGCAI GUprogress
07/19/2023Fire-Resistance Rated ConstructionXIONGCAI GUprogress
05/25/2023Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
05/25/2023Energy Code Compliance InspectionsXIONGCAI GUprogress
05/25/2023Fire-Resistance Rated ConstructionXIONGCAI GUprogress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/25/2026Q08049874-P2Request digital key ↗
08/25/2026Q08049874-P1Request digital key ↗
08/25/2026Q08049874-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
04/04/2023440774495Open ↗
▸BISWORK PERMIT APPLICATION1
07/13/2023440774495Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/25/2026Q08049874-P2Open ↗
08/25/2026Q08049874-P1Open ↗
08/25/2026Q08049874-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q08049874-P1Open ↗
08/26/2026Q08049874-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q08049874-P1Open ↗
08/26/2026Q08049874-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
04/04/2023440774495Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/04/2023440774495Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
07/13/2023440774495Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/04/2023440774495Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
03/10/2025440774495Open ↗
04/04/2023440774495Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/10/2025440774495Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
03/12/2025440774495Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
04/04/2023440774495Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/04/2023440774495Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/10/2025440774495Open ↗
04/04/2023440774495Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/12/2025440774495Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/12/2025440774495Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/10/2025440774495Open ↗
04/04/2023440774495Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
07/10/2023440774495Open ↗
04/04/2023440774495Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/04/2023440774495Open ↗