← Back
Health center, child center, clinic
34-35 70 STREET
QUEENS · BIN 4028823
💬 Discuss this project
1939Year Built
1Stories
I5Building Class
R5Zoning
17,965 sfGross Floor Area
1Units
Health center, child center, clinic · Owner of record: 34-35 70TH STREET JOINT VENTURE LLC · 18,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalGeneral
Roof6p · 1 filing · 9 docs
Floor 11p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
34-35 70TH STREET JOINT VENTURE1007/08/2026
BOHLER ENGINEERING303/22/2026
34-35TH STREET PARTNERS503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PETRVS208/06/2024
PINNACLE ENGINEERS PC108/02/2024
MARCY ENGINEERING, PLLC110/02/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BOHLER ENGINEERING303/21/2026
BAZINI ENGINEERING P C203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ABSOLUTE COOLING AND HEATGeneral Contractor307/08/2026
ECC GROUP INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BAZINI ENGINEERING, P.C.1808110/02/2020
Building Lifecycle
All (23)Filed (4)Permit Issued (3)Signed Off (1)Objection (12)Special Inspection (3)
09/04/2024
Objection resolved — Addressed
08/26/2024
Objection resolved — Addressed
08/26/2024
Objection resolved — Addressed
08/26/2024
Objection resolved — Addressed
08/26/2024
Objection resolved — Addressed
08/14/2024
Objection raised — Scope
08/14/2024
Objection raised — Structural
08/14/2024
Objection raised — Admin
08/14/2024
Objection raised — Structural
08/14/2024
Objection raised — Other
08/09/2024
Objection resolved — Addressed
08/06/2024
Filed — Alteration
Renovations to the 1st Fl. of a one-story, single tenant building. A new vestibule and entrance door, as well as renovations to the existing waiting for Fresenius Medical Facility as per plans. There will be no change in use, egress, or occupancy.
Q01084538-I1
08/06/2024
Objection raised — Scope
08/02/2024
Filed — Alteration
HVAC modifications and associated ductwork as per plans. There will be no change in use, egress, or occupancy.
Q01084585-I1
07/23/2024
Special inspection requirement — Mechanical Systems
07/23/2024
Special inspection requirement — Final
04/04/2023
Signed off — Alteration
Q00830366-I1
04/03/2023
Permit issued — General Construction
Q00830366-I1-GC
02/16/2023
Filed — Alteration
Q00830366-I1
02/16/2023
Special inspection requirement — Final
Joseph Deal
12/14/2021
Permit issued — Mechanical Systems
Q00404454-I1-MS
10/05/2020
Permit issued — Mechanical Systems
Q00404454-I1-MS
10/02/2020
Filed — Alteration
INSTALL THREE (3) REPLACEMENT HVAC UNITS ON ROOF AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00404454-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offECC GROUP INC04/03/2023
DOB NOWMechanical SystemsPermit IssuedABSOLUTE COOLING HEAT12/14/2021
DOB NOWMechanical SystemsPermit IssuedABSOLUTE COOLING HEAT10/05/2020
BISPLISSUEDSTELLMAR PLBG & MECH.CORP07/09/2012
BISOTISSUEDCAPITOL AWNING CO INC08/04/2011
BISOTISSUEDCAPITOL AWNING CO INC08/04/2011
BISPLISSUEDSTELLMAR PLBG & MECH.CORP01/21/2011
BISMHISSUEDMONTEREY CONSTRUCTION COR01/14/2011
BISMHISSUEDMONTEREY CONSTRUCTION COR12/24/2009
BISPLISSUEDSTELLMAR PLBG & MECH.CORP10/27/2009
BISMHISSUEDMONTEREY CONSTRUCTION COR01/02/2009
BISPLISSUEDSTELLMAR PLBG & MECH.CORP10/07/2008
BISOTISSUEDMONTEREY CANSTRUCTION CORP08/19/2008
BISPLISSUEDMAGOR PLUMBING & HEATING11/03/1997
BISMHISSUEDULTRA COOLING CORP07/22/1997
1 project · most recent 10/02/2020
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/02/2020Permit IssuedABSOLUTE COOLING AND HEATAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
York ZF090N18R2A1AAA1A2 SER #N2A1592029 90,000 BTU ×4
ZF150N24R2A1BAA1A1 SER #N2K0168393 148,000 BTU · Rooftop Unit ×4
ZF150N24R2A1BAA1A1 SER #N2K0206870 148,000 BTU · Rooftop Unit ×4
Heating
York ZF090N18R2A1AAA1A2 SER #N2A1592029 180,000 BTU ×4
ZF150N24R2A1BAA1A1 SER #N2K0168393 240,000 BTU · Rooftop Unit ×4
ZF150N24R2A1BAA1A1 SER #N2K0206870 240,000 BTU · Rooftop Unit ×4
Ventilation
York ZF090N18R2A1AAA1A2 SER #N2A1592029 2,500 CFM ×4
ZF150N24R2A1BAA1A1 SER #N2K0168393 4,050 CFM · Rooftop Unit ×4
ZF150N24R2A1BAA1A1 SER #N2K0206870 4,050 CFM · Rooftop Unit ×4
2 projects · most recent 11/07/2025
FiledStatusContractorScope
11/07/2025Permit IssuedHYLAN DATACOM & ELECL LLC1 meters, 1 new_meters
02/14/2022Permit IssuedANCO ELECTL CONTCTNG INC1 meters
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
07/23/2024Mechanical Systems—special
07/23/2024Final—progress
02/16/2023FinalJoseph Dealprogress
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch3
08/25/2026Q00830366-I1Request digital key ↗
08/21/2026Q01084585-I1Request digital key ↗
08/21/2026Q01084538-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/27/2026Q00404454-I1Request digital key ↗
08/15/2026Q00404454-P1Request digital key ↗
▸Applications & Permits17
▸BISWORK PERMIT APPLICATION13
08/05/2011420366669Open ↗
08/05/2011420366650Open ↗
01/24/2011410121960Open ↗
Showing 3 of 13 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
06/20/2011420366669Open ↗
06/13/2011420366650Open ↗
06/10/2008410121979Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications15
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
05/15/2012420366650Open ↗
05/14/2012420366669Open ↗
06/20/2011420366669Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/27/2026Q00404454-I1Open ↗
08/27/2026Q00404454-P1Open ↗
08/25/2026Q00830366-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q00830366-I1Open ↗
08/23/2026Q00404454-P1Open ↗
08/23/2026Q00404454-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00404454-P1Open ↗
▸Trade Schedules & Equipment10
▸BISSELF-CERT PLUMBING NOTICE8
11/27/2012410121960Open ↗
11/02/2012410121960Open ↗
08/31/2012410121960Open ↗
Showing 3 of 8 on file for this type
▸BISSCHEDULE B - PLUMBING2
06/10/2008410121979Open ↗
06/10/2008410121960Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026Q00404454-P1Open ↗
08/27/2026Q00404454-I1Open ↗
08/13/2026Q01084585-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
06/10/2008410121979Open ↗
06/10/2008410121960Open ↗
▸BISASBESTOS-EXEMPTION (ASB4)1
06/16/2011420366650Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
06/20/2011420366669Open ↗
▸Approvals, Objections & Sign-offs8
▸BISADMINISTRATIVE OBJECTIONS4
06/20/2011420366669Open ↗
06/13/2011420366650Open ↗
06/10/2008410121979Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
05/14/2012420366650Open ↗
05/14/2012420366669Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
05/14/2012420366650Open ↗
05/14/2012420366669Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
05/14/2012420366650Open ↗
05/14/2012420366669Open ↗
06/20/2011420366669Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET4
06/20/2011420366669Open ↗
06/13/2011420366650Open ↗
06/10/2008410121979Open ↗
Showing 3 of 4 on file for this type