ECB05/23/2003FAILURE TO PROVIDE MINIMUM # OF PARKING SPACES FOR ZONING LOT.ENCLOSED SPACES PROVIDED HAVE BEEN CONVERTED TO HABITABLE ROOMS DO NOT MEET THE MINIMUM SIZE REQUIREMENTS ARE NOT MANEUNERABLENothing owed — awaiting certificate of correction
ECB05/19/2003GUARDRAILS NOT PROVIDED AT ROOF. GUARDRAILS/PARAPET MUST BE MINIMUM OF 3'6' HIGH. REMEDY: PROVIDE GUARDRAILS.Nothing owed — awaiting certificate of correction
ECB05/19/200310 FT LINE WINDOW USED TO PROVIDE REQUIRED VENTILATION REMEDY: PROVIDE ALTERNATE MEANS OF VENTILATIONNothing owed — awaiting certificate of correction
ECB05/19/20031 HR FIRE RATED WALL AT BOILER ENCLOSURE IS PENETRATED BY UNRATED CLOTHES DRYER FL REMEDY: PROVIDE RATED FL OR REMOVE AND PATCH HOLENothing owed — awaiting certificate of correction
ECB05/19/2003INTERIOR STAIR AND ROOF BULKHEAD NOT PROVIDED IN 4 FAMILY DWELLING. REMEMDY: PROVIDE BULKHEAD AND STAIRNothing owed — awaiting certificate of correction
ECB05/19/2003LADDER TO ROOF SCUTTLE AT 4TH FLOOR IS MISSING/ INCONVENIENTLY LOCATED, MAKING ACCESS TO SCUTTLE DIFFICULT. REMEDY: PROVIDE LADDER/ REPOSITION LADDER TO MAKE ROOF READILY ACCESSIBLE.Nothing owed — awaiting certificate of correction
ECB05/19/2003FAILURE TO PROVIDE REQUIRED VENTED GLASS SKYLIGHT WITH WIRE GRATING ABOVE AND BELOW. REMEMDY: PROVIDE REQUIRED SKYLIGHT/GRATING.Nothing owed — awaiting certificate of correction
ECB05/19/2003CELLAR STAIR NOT ENCLOSED IN FIRE RATED PARTITIONS REMEDY: PROVIDE STAIR ENCLOSURE AND FPSC DOORS AT TOP AND BOTTOMNothing owed — awaiting certificate of correction
ECB05/19/2003APARTMENT DOOR OPEN DIRECTLY INTO STAIR ENCLOSURE NOT PERMITTED IN BOILING OVER THREE STORIES REMEDY: PROVIDE VESTIBLENothing owed — awaiting certificate of correction
ECB05/19/2003BOILER FLUE NOT CARRIED MINIMUM OF 3 FEET ABOVE ROOF PARAPET WALL. REMEDY: EXTEND BOILER FLUENothing owed — awaiting certificate of correction
ECB05/10/2003ROOF DECK IS PLYWOOD AND DOES NOT MEET MINIMUM REQUIREMENTS FOR CLASS I NON COMBUSTIBLE CONSTRUCTIONNothing owed — awaiting certificate of correction