← Back
Office only, 2-6 stories
34 EAST 39 STREET
MANHATTAN · Midtown-Times Square · BIN 1017237
💬 Discuss this project
1938Year Built
5Stories
O2Building Class
R8BZoning
6,872 sfGross Floor Area
10Units
5 Open Violations ▸
Office only, 2-6 stories · Owner of record: 34 EAST 39 ST LLC · 2,024 sf lot · 3.4 FAR built · Flood zone X
Locations of Work
StructuralMechanicalPlumbingFire ProtectionGeneral
Filed — no permit issued48p · 7 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/01/2020$6.0M—RUSKIN ASSOCIATES LLC → 34 EAST 39 ST LLC$873/sf building
▾Design Consultants (Architect / Engineer of Record)
Building Lifecycle
All (66)Filed (8)Violation (8)Objection (29)Special Inspection (21)
08/27/2026
Filed — Alteration CO
Obtain new Certificate of Occupancy. Facade Work and interior renovation work.
M08030069-P1
07/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
12/09/2024
Objection raised — Inspections
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Structural
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Structural
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Admin
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Inspections
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Structural
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Structural
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Other
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Admin
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Structural
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Structural
12/09/2024
Objection resolved — Addressed
12/09/2024
Objection raised — Other
12/09/2024
Objection resolved — Addressed
11/26/2024
Filed — Alteration
Shoring and Underpinning, New Step footing, Lower cellar floor 2 feet down.
M01125997-I1
09/24/2024
Objection raised — Other
09/16/2024
Objection resolved — Addressed
11/15/2022
Objection raised — Scope
11/15/2022
Objection resolved — Addressed
11/15/2022
Objection raised — Other
11/04/2022
Filed — Alteration CO
Obtain new Certificate of Occupancy. Facade Work and interior renovation work.
M08030069-I1
11/04/2022
Filed — Alteration
M08032990-I1
11/04/2022
Filed — Alteration
M08032378-I1
11/04/2022
Filed — Alteration
Structural Steel Support and Concrete work
M08033270-I1
11/04/2022
Filed — Alteration
Installation of Air conditioning unit and exhaust system on existing mix used building
M08033357-I1
11/04/2022
Filed — Alteration
M08033324-I1
11/02/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
11/02/2022
Special inspection requirement — Final
11/02/2022
Special inspection requirement — HVAC-R and service water heating equipment
11/02/2022
Special inspection requirement — HVAC-R and service water heating system controls
11/02/2022
Special inspection requirement — Maintenance information
11/02/2022
Special inspection requirement — Shutoff dampers
11/02/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
11/02/2022
Special inspection requirement — Underpinning
11/02/2022
Special inspection requirement — Structural Cold-Formed Steel
11/02/2022
Special inspection requirement — Structural Steel - Details
11/02/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
11/02/2022
Special inspection requirement — Final
11/02/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/02/2022
Special inspection requirement — Mechanical Systems
11/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/01/2022
Special inspection requirement — Post-installed Anchors
11/01/2022
Special inspection requirement — Sprinkler Systems
11/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/28/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
12/14/2020
Violation issued (HPD, closed)
B
12/14/2020
Violation issued (HPD, closed)
B
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDSTEINWAY AWNING II, LLC08/15/2016
BISFBISSUEDDUAL FUEL PLUMBING AND HEATING05/27/1999
1 project · most recent 11/04/2022
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/04/2022——Air Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric mxz-3c24nahz 24,000 BTU · Condensing Unit ×8
Ventilation
Greenheck G-097-VG 190 CFM · Exhaust Fan ×2
G-103HP-VG 410 CFM · Kitchen Exhaust ×1
2 projects · most recent 11/26/2024
Steel Concrete
FiledStatusContractorScope
11/26/2024——1 scope_items
11/04/2022——Steel, Concrete
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
07/24/2026Fire-Resistant Penetrations and Joints—special
07/24/2026Structural Stability – Alterations of existing buildings—special
11/02/2022HVAC-R and service water piping design and insulation—energy_progress
11/02/2022Final—progress
11/02/2022HVAC-R and service water heating equipment—energy_progress
11/02/2022HVAC-R and service water heating system controls—energy_progress
11/02/2022Maintenance information—energy_progress
11/02/2022Shutoff dampers—energy_progress
11/02/2022Structural Stability – Alterations of existing buildings—special
11/02/2022Underpinning—special
11/02/2022Structural Cold-Formed Steel—special
11/02/2022Structural Steel - Details—special
11/02/2022Structural Stability – Alterations of existing buildings—special
11/02/2022Final—progress
11/02/2022Fire-Resistant Penetrations and Joints—special
11/02/2022Mechanical Systems—special
11/01/2022Fire-Resistant Penetrations and Joints—special
11/01/2022Post-installed Anchors—special
11/01/2022Sprinkler Systems—special
11/01/2022Fire-Resistant Penetrations and Joints—special
10/28/2022Structural Stability – Alterations of existing buildings—special
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/01/2026M08032378-I1Request digital key ↗
09/01/2026M08033270-I1Request digital key ↗
09/01/2026M08032990-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
08/18/2016122851182Open ↗
▸BISWORK PERMIT APPLICATION1
08/18/2016122851182Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/14/2026M08030069-P1Open ↗
09/01/2026M08033357-I1Open ↗
09/01/2026M08033270-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/18/2016122851182Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/18/2016122851182Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/21/2016122851182Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
09/14/2026M08030069-P1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
09/14/2026M08030069-P1Open ↗
09/01/2026M08033270-I1Open ↗
09/01/2026M08032990-I1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/18/2016122851182Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/21/2016122851182Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/21/2016122851182Open ↗
08/18/2016122851182Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
08/18/2016122851182Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
09/14/2026M08030069-P1Open ↗