← Back
Two family frame
341 BLEECKER STREET
BROOKLYN · BIN 3075502
💬 Discuss this project
1899Year Built
3Stories
B2Building Class
R6Zoning
2,376 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family frame · 1,800 sf lot · 1.32 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Floor 32p · 2 filings · 20 docs
Floor 2
Floor 11p · 1 filing · 18 docs
Cellar1p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/26/2023$1.3M—— → —$533/sf building
12/19/2014$610K—— → —$257/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
XIAOPENG WANG DESIGN LLC402/13/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RIKARD VUKAGeneral Contractor207/08/2026
CRESCO ELECTRICAL CORPElectrical103/22/2026
EUSEBIO MCQUEENElectrical103/21/2026
MCQUEEN EUSEBIOElectrical103/21/2026
NEW CENTURY ELEC'L CONTRElectrical103/22/2026
JCVC GENERAL CONSTRUCTIONGeneral Contractor107/08/2026
BENJAMIN DREBINElectrical103/21/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SIA INSPECTIONS LLC7306302/13/2025
Building Lifecycle
All (38)Filed (4)Permit Issued (4)Violation (6)Inspection (3)Objection (2)Special Inspection (19)
02/13/2025
Filed — Alteration
Interior renovation of a town house. Replacing a stair, relocating a bathroom, updating existing kitchen, replacing fixtures in all bathrooms and installing HVAC units. No change in use, occupancy and egress.
B00920588-P1
02/12/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
JEFF AKERMAN
02/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JEFF AKERMAN
02/12/2025
Special inspection requirement — Heating Systems
JEFF AKERMAN
02/12/2025
Special inspection requirement — Mechanical Systems
JEFF AKERMAN
02/12/2025
Special inspection requirement — Energy Code Compliance Inspections
JEFF AKERMAN
02/12/2025
Special inspection requirement — Final
SOFIA KAPELYAN
02/12/2025
Special inspection requirement — Maintenance information
JEFF AKERMAN
02/12/2025
Special inspection requirement — Electrical motors and elevators
JEFF AKERMAN
02/12/2025
Special inspection requirement — Lighting in dwelling units
JEFF AKERMAN
01/02/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/30/2024
Permit issued — General Construction
B00920588-I1-GC-CX
06/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/13/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/03/2024
Permit issued — Plumbing
B00920588-S1-PL
05/21/2024
Filed — Alteration
Interior renovation of a town house. Replacing a stair, relocating a bathroom, updating existing kitchen, replacing fixtures in all bathrooms and installing HVAC units. No change in use, occupancy and egress.
B00920588-S1
05/15/2024
Permit issued — Mechanical Systems
B00920588-I1-GC-CX
08/28/2023
Permit issued — General Construction
B00920588-I1-GC-CX
08/17/2023
Filed — Alteration
Interior renovation of a town house. Replacing a stair, relocating a bathroom, updating existing kitchen, replacing fixtures in all bathrooms and installing HVAC units. No change in use, occupancy and egress.
B00920588-I1
06/20/2023
Objection raised — Scope
06/20/2023
Objection resolved — Resolved
06/12/2023
Filed — Alteration
Interior renovation of a town house. Replacing a stair, relocating a bathroom, updating existing kitchen, replacing fixtures in all bathrooms and installing HVAC units. No change in use, occupancy and egress.
B00878109-I1
06/09/2023
Special inspection requirement — Electrical motors and elevators
JEFF AKERMAN
06/09/2023
Special inspection requirement — Heating Systems
JEFF AKERMAN
06/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JEFF AKERMAN
06/09/2023
Special inspection requirement — Energy Code Compliance Inspections
JEFF AKERMAN
06/09/2023
Special inspection requirement — Shutoff dampers
JEFF AKERMAN
06/09/2023
Special inspection requirement — Lighting in dwelling units
JEFF AKERMAN
06/09/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
JEFF AKERMAN
06/09/2023
Special inspection requirement — Maintenance information
JEFF AKERMAN
05/19/2023
Special inspection requirement — Mechanical Systems
JEFF AKERMAN
05/19/2023
Special inspection requirement — Final
SOFIA KAPELYAN
06/24/2014
Violation issued (HPD, closed)
B
06/24/2014
Violation issued (HPD, closed)
B
06/24/2014
Violation issued (HPD, open)
C
06/24/2014
Violation issued (HPD, open)
B
07/14/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2005
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offJCVC GENERAL CONSTRUCTION10/30/2024
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP06/03/2024
DOB NOWMechanical SystemsSigned-offRIKARD VUKA05/15/2024
DOB NOWGeneral ConstructionSigned-offRIKARD VUKA08/28/2023
BISPLISSUEDJADA PLUMBING & HTG LLC10/02/2015
BISOTISSUEDHV DRAFTING & DESIGN ASSO09/30/2015
2 projects · most recent 02/13/2025
Associated Ducts and Piping Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/13/2025Signed-offJCVC GENERAL CONSTRUCTIONAssociated Ducts and Piping, Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MLZ-KP09NA2 1 tons · Fan Coil Indoor ×2
MSZ-GL12NA 1 tons · Fan Coil Indoor ×2
PEAD-A12AA8 1 tons · Vrf Indoor ×2
MSZ-GL09NA 11,000 BTU · Fan Coil Indoor ×1
MSZ-GS09NA 11,000 BTU · Fan Coil Indoor ×1
MXZ-SM36NAMHZ 36,000 BTU · Vrf Outdoor ×1
MXZ-SM48NAMHZ 48,000 BTU · Vrf Outdoor ×1
Ducts & Piping
N/A NA 11,000 tons · Ductwork ×8
06/12/2023——Associated Ducts and Piping, Heating and Air Conditioning Systems—
1 project · most recent 02/13/2025
Water/Sanitary
FiledStatusContractorScope
02/13/2025Signed-offDPH PLUMBING & HTG CORPWater/Sanitary
2 projects · most recent 10/13/2025
General Wiring
FiledStatusContractorScope
10/13/2025Permit IssuedNEW CENTURY ELEC'L CONTRGeneral Wiring
04/24/2024Permit IssuedCRESCO ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/02/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/13/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
02/12/2025HVAC-R and service water piping design and insulationJEFF AKERMANenergy_progress
02/12/2025Fire-Resistant Penetrations and JointsJEFF AKERMANspecial
02/12/2025Heating SystemsJEFF AKERMANspecial
02/12/2025Mechanical SystemsJEFF AKERMANspecial
02/12/2025Energy Code Compliance InspectionsJEFF AKERMANprogress
02/12/2025FinalSOFIA KAPELYANprogress
02/12/2025Maintenance informationJEFF AKERMANenergy_progress
02/12/2025Electrical motors and elevatorsJEFF AKERMANenergy_progress
02/12/2025Lighting in dwelling unitsJEFF AKERMANenergy_progress
06/09/2023Electrical motors and elevatorsJEFF AKERMANenergy_progress
06/09/2023Heating SystemsJEFF AKERMANspecial
06/09/2023Fire-Resistant Penetrations and JointsJEFF AKERMANspecial
06/09/2023Energy Code Compliance InspectionsJEFF AKERMANprogress
06/09/2023Shutoff dampersJEFF AKERMANenergy_progress
06/09/2023Lighting in dwelling unitsJEFF AKERMANenergy_progress
06/09/2023HVAC-R and service water piping design and insulationJEFF AKERMANenergy_progress
06/09/2023Maintenance informationJEFF AKERMANenergy_progress
05/19/2023Mechanical SystemsJEFF AKERMANspecial
05/19/2023FinalSOFIA KAPELYANprogress
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00920588-P1Request digital key ↗
08/27/2026B00920588-S1Request digital key ↗
08/27/2026B00920588-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION9
07/12/2023302240750Open ↗
05/02/2023321130361Open ↗
04/19/2023321130361Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION2
10/06/2015321130361Open ↗
10/02/2015321130361Open ↗
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature13
09/27/2026B00878109-I1Open ↗
09/27/2026B00878109-I1Open ↗
09/27/2026B00878109-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/27/2026B00878109-I1Open ↗
09/27/2026B00878109-I1Open ↗
09/27/2026B00878109-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00920588-I1Open ↗
08/13/2026B00920588-P1Open ↗
08/13/2026B00920588-S1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/09/2015321130361Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/09/2015321130361Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
06/09/2015321130361Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/02/2015321130361Open ↗
06/09/2015321130361Open ↗
▸BISSCHEDULE B - PLUMBING1
04/19/2023321130361Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026B00920588-I1Open ↗
08/13/2026B00878109-I1Open ↗
08/13/2026B00920588-S1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/09/2015321130361Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/09/2015321130361Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/09/2015321130361Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
05/02/2023321130361Open ↗
08/05/2015321130361Open ↗
▸BISEFILING COVER SHEET1
06/09/2015321130361Open ↗