← Back
BuildNYC
Two family frame
341 DARLINGTON AVENUE
STATEN ISLAND · BIN 5110856
💬 Discuss this project
1992Year Built
2Stories
B2Building Class
R3XZoning
4,160 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family frame · 7,700 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
Plumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Cellar6p · 1 filing · 19 docs
Site & exterior6p · 1 filing · 19 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Design Build SI203/09/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Design Build SI403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
R McGlynn PlumbingPlumbing103/21/2026
Patriot Plumbing & HeatingPlumbing107/08/2026
Sea Bright SolarGeneral Contractor112/04/2015
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Design Build, SI6114203/09/2023
Building Lifecycle
06/09/2023
Signed off — Alteration
APPLIC FILED FOR INSTALLATION OF 1 NEW GAS-FIRED STANDBY GENERATOR, 1 NEW GAS-FIRED POOL HEATER AND 1 NEW GAS-FIRED SNOW MELT BOILER. INSTALLATION OF 1 GAS-FIRED COMBINATION HOT WATER BOILER/HEATER TO REPLACE ONE EX. BOILER AND ONE EX. HOT WATER HEATER
S00563559-I1
05/25/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/19/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/14/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/06/2023
Objection resolved — Addressed
32 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPatriot Plumbing & Heating08/10/2022
BISOTISSUEDSea Bright Solar12/04/2015
BISPLISSUEDR. McGlynn Plumbing03/20/2014
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/25/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/19/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/14/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/09/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/27/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
04/06/2023Fire-Resistant Penetrations and JointsGiuseppe Bonomospecial
04/06/2023Energy Code Compliance InspectionsGiuseppe Bonomoprogress
04/06/2023HVAC-R and service water heating system controlsGiuseppe Bonomoenergy_progress
04/06/2023Maintenance informationGiuseppe Bonomoenergy_progress
04/06/2023HVAC-R and service water heating equipmentGiuseppe Bonomoenergy_progress
04/06/2023Permanent certificateGiuseppe Bonomoenergy_progress
04/06/2023HVAC-R and service water piping design and insulationGiuseppe Bonomoenergy_progress
03/09/2023Fire-Resistant Penetrations and JointsGiuseppe Bonomospecial
03/09/2023Energy Code Compliance InspectionsGiuseppe Bonomoprogress
03/09/2023HVAC-R and service water heating equipmentGiuseppe Bonomoenergy_progress
03/09/2023Maintenance informationGiuseppe Bonomoenergy_progress
03/09/2023Permanent certificateGiuseppe Bonomoenergy_progress
03/09/2023HVAC-R and service water piping design and insulationGiuseppe Bonomoenergy_progress
03/09/2023HVAC-R and service water heating system controlsGiuseppe Bonomoenergy_progress
55 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account