ECB04/21/2023AS PER ONE WEIL MCLAIN EGH-125 STEAM BOILER; EXPOSED ELECTRICAL WIRING. OPEN ELECTRICAL BOXES IN CEILING. BOILER ROOM TEMPERATURE ABOVE THAT ALLOWED BY CODE. NO INSULATION ON STEAM PIPING. NO CLEAN-OUT AT CHIMN$625 due
HPD04/06/2022§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/06/2022§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/06/2022§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR ... AT PUBLIC HALL, 1st STORY
HPD04/06/2022§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/06/2022§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL APPROX 2 SQ FT IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 15089500 ISSUED 06-APR-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD04/06/2022§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/06/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
ECB02/08/2022FOUND HOLES IN WALL AND CEILING. EXPSOED WIRES. NO MANUAL RESET LOW WATER CUTOFF. BANGING AT RADIATORS IN APARTMENTS, HEAT TIMER SETTING NOT AS PER CITY REGULATION OF 55 DEGREES FROM 5AM-10PM. 45DEGREES FROM 10$3K due
ECB04/26/2021FOUND EXPOSED WIRING, GLASS GAUGE GUARDS MISSING, DISCHARGE PIPE AT BACK FLOW PREVENTER MISSING, CORRODED FITTING AT SKIMMING VALVE,$3K due
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
HPD03/13/2018§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD03/12/2018§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD03/12/2018§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD03/12/2018§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD10/18/2017§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING ENTRANCE DOOR LOCATED AT APT 1A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD10/18/2017§ 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS , LOCATED AT APT 1A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD10/18/2017§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , LOCATED AT APT 1A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD10/18/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , LOCATED AT APT 1A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD09/30/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING AND SOUTH WALL AT THE VESTIBULE WITH FIRE RETARDENT MATERIAL , 1st STORY
HPD09/30/2016SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND SOUTH WALL OF THE VESTIBULE , 1st STORY
HPD09/30/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WEST WALL WITH FIRE RETARDENT MATERIAL AT ALL STORIES AT PUBLIC HALL
HPD09/30/2016SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL AT ALL STORIES AT PUBLIC HALL
HPD05/11/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL AT ALL STORIES AT PUBLIC HALL
HPD05/11/2016SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL AT ALL STORIES AT PUBLIC HALL
HPD12/31/1986D26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS REQUIRED LIGHT NOT ON.
HPD06/23/1983D26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING NIGHT INSPEC FIXTURES PRESENT LIGHTS NOT ON.
ECB04/11/2016GAS BEING SUPPLIED TO BLDG W/O INSPECTION &CERTIFICATION NY DOB.ON THEABOVE DATE @4:10PM I OBERVED NEW GAS PIPING DEEFING BOILER(THAT WAS ACTIVE)W. NO TESTING OR CERTIFICATIONS BY DOB.REM:FILE FOR REQUIRED PERMNothing owed — awaiting certificate of correction
ECB03/01/2016FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.RE:INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC 102.3:27-902.PROHIBITEDMATERIALS.@THE ABOVE DATE @APPROX 1:20PM I OBSERVED THE INSTALLATION ONothing owed — awaiting certificate of correction