← Back
Two family frame
3416 BAILEY PLACE
💬 Discuss this project
1899Year Built
2.5Stories
B2Building Class
R6Zoning
2,543 sfGross Floor Area
2Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Two family frame · 1,658 sf lot · 1.53 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbing
Cellar2p · 1 filing · 20 docs
Basement1p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/21/2023$1.1M—BAILEY STAR LLC → Private party$423/sf building
09/22/2020$470K—MTGLQ INVESTORS, L.P. → MARTIN STREET DEVELOPERS, LLC$185/sf building
05/22/2019$548K—Private party → MTGLQ INVESTORS, LP$215/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SELF EMPLOYED411/01/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Younes Abouyaala PE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AUSTIN PLBG & HTG CO.INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519411/01/2021
Building Lifecycle
All (45)Filed (4)Permit Issued (1)Signed Off (1)Violation (11)Special Inspection (28)
11/24/2025
Violation issued (HPD, open)
I
12/03/2024
Violation issued (HPD, open)
I
11/04/2022
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT-1 JOB# 240297460 .
X00459739-I1
11/03/2021
Special inspection requirement — Maintenance information
NAVEEN KUMAR
11/03/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
NAVEEN KUMAR
11/03/2021
Special inspection requirement — HVAC-R and service water heating equipment
NAVEEN KUMAR
11/03/2021
Special inspection requirement — HVAC-R and service water heating system controls
NAVEEN KUMAR
11/03/2021
Special inspection requirement — Energy Code Compliance
Younes Abouyaala
11/03/2021
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
11/03/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
11/01/2021
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT-1 JOB# 240297460 .
X00459739-P4
11/01/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
11/01/2021
Special inspection requirement — Energy Code Compliance
Younes Abouyaala
11/01/2021
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
11/01/2021
Special inspection requirement — HVAC-R and service water heating system controls
NAVEEN KUMAR
11/01/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
NAVEEN KUMAR
11/01/2021
Special inspection requirement — Maintenance information
NAVEEN KUMAR
11/01/2021
Special inspection requirement — HVAC-R and service water heating equipment
NAVEEN KUMAR
10/13/2021
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT-1 JOB# 240297460 .
X00459739-P2
10/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
10/13/2021
Special inspection requirement — Maintenance information
NAVEEN KUMAR
10/13/2021
Special inspection requirement — HVAC-R and service water heating equipment
NAVEEN KUMAR
10/13/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
NAVEEN KUMAR
10/13/2021
Special inspection requirement — HVAC-R and service water heating system controls
NAVEEN KUMAR
10/13/2021
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
10/13/2021
Special inspection requirement — Energy Code Compliance
Younes Abouyaala
10/01/2021
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT-1 JOB# 240297460 .
X00459739-P1
10/01/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
10/01/2021
Special inspection requirement — Energy Code Compliance
Younes Abouyaala
10/01/2021
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
10/01/2021
Special inspection requirement — Maintenance information
NAVEEN KUMAR
10/01/2021
Special inspection requirement — HVAC-R and service water heating equipment
NAVEEN KUMAR
10/01/2021
Special inspection requirement — HVAC-R and service water heating system controls
NAVEEN KUMAR
10/01/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
NAVEEN KUMAR
02/17/2021
Permit issued — Plumbing
X00459739-I1-PL
02/09/2021
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALT-1 JOB# 240297460 .
X00459739-I1
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
B
06/02/2012
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAUSTIN PLBG & HTG CO.INC02/17/2021
BIS—ISSUEDSUPERB CONSTRUCTION MGT10/05/2021
BISOTISSUEDMORELL BUILDERS INC11/11/2020
1 project · most recent 06/12/2023
General Wiring
FiledStatusContractorScope
06/12/2023CompleteKOPP ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
11/03/2021Maintenance informationNAVEEN KUMARenergy_progress
11/03/2021HVAC-R and service water piping design and insulationNAVEEN KUMARenergy_progress
11/03/2021HVAC-R and service water heating equipmentNAVEEN KUMARenergy_progress
11/03/2021HVAC-R and service water heating system controlsNAVEEN KUMARenergy_progress
11/03/2021Energy Code ComplianceYounes Abouyaalaprogress
11/03/2021Energy Code Compliance InspectionsYounes Abouyaalaprogress
11/03/2021Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
11/01/2021Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
11/01/2021Energy Code ComplianceYounes Abouyaalaprogress
11/01/2021Energy Code Compliance InspectionsYounes Abouyaalaprogress
11/01/2021HVAC-R and service water heating system controlsNAVEEN KUMARenergy_progress
11/01/2021HVAC-R and service water piping design and insulationNAVEEN KUMARenergy_progress
11/01/2021Maintenance informationNAVEEN KUMARenergy_progress
11/01/2021HVAC-R and service water heating equipmentNAVEEN KUMARenergy_progress
10/13/2021Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
10/13/2021Maintenance informationNAVEEN KUMARenergy_progress
10/13/2021HVAC-R and service water heating equipmentNAVEEN KUMARenergy_progress
10/13/2021HVAC-R and service water piping design and insulationNAVEEN KUMARenergy_progress
10/13/2021HVAC-R and service water heating system controlsNAVEEN KUMARenergy_progress
10/13/2021Energy Code Compliance InspectionsYounes Abouyaalaprogress
10/13/2021Energy Code ComplianceYounes Abouyaalaprogress
10/01/2021Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
10/01/2021Energy Code ComplianceYounes Abouyaalaprogress
10/01/2021Energy Code Compliance InspectionsYounes Abouyaalaprogress
10/01/2021Maintenance informationNAVEEN KUMARenergy_progress
Latest 25 of 28.
▾Documents — 114 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing4
08/25/2026X00459739-I1Request digital key ↗
08/15/2026X00459739-P4Request digital key ↗
08/15/2026X00459739-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION8
03/21/2024240297460Open ↗
10/10/2023240297460Open ↗
09/13/2023240297460Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
10/27/2023240297460Open ↗
10/18/2021240297460Open ↗
▸BISWORK PERMIT APPLICATION2
10/05/2021240297460Open ↗
11/11/2020240293400Open ↗
▸BISOPEN APPLICATIONS SEARCH1
12/21/2021240297460Open ↗
▸Zoning, Tax Lot & Property Records6
▸BISZONING DIAGRAM2
10/27/2023240297460Open ↗
05/25/2021240297460Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
10/27/2023240297460Open ↗
▸BISVERIFY TAX LOT1
04/06/2024240297460Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
04/06/2024240297460Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
10/27/2023240297460Open ↗
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature12
08/29/2026X00459739-P4Open ↗
08/29/2026X00459739-P4Open ↗
08/29/2026X00459739-P4Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026X00459739-P1Open ↗
08/25/2026X00459739-I1Open ↗
08/25/2026X00459739-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026X00459739-P4Open ↗
08/28/2026X00459739-I1Open ↗
08/26/2026X00459739-P2Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/24/2021240297460Open ↗
11/06/2020240293400Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
11/06/2020240293400Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/06/2020240293400Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
05/25/2021240297460Open ↗
▸Trade Schedules & Equipment1
▸BISPLUMBING (PL) SIGNOFF1
12/21/2021240297460Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
05/25/2021240297460Open ↗
▸BISSTREET TREE SIGNOFF1
12/21/2021240297460Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/25/2026X00459739-P1Open ↗
08/25/2026X00459739-I1Open ↗
08/25/2026X00459739-P4Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
05/25/2021240297460Open ↗
05/25/2021240297460Open ↗
11/06/2020240293400Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
10/18/2021240297460Open ↗
09/27/2021240297460Open ↗
07/19/2021240297460Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
11/28/2022240293400Open ↗
11/09/2022240293400Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
04/06/2024240297460Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/06/2020240293400Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00459739-I1Open ↗
▸Inspections & Test Reports24
▸BISTECHNICAL REPORT: RESPONSIBILITY18
10/19/2023240297460Open ↗
05/26/2023240293400Open ↗
11/28/2022240293400Open ↗
Showing 3 of 18 on file for this type
▸BISSUBGRADE INSP / SOILS-SITE PREP1
12/21/2021240297460Open ↗
▸BISDEMOLITION1
06/06/2023240293400Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
05/25/2021240297460Open ↗
▸BISFRAME (2008)/STRUCTURAL WOOD FRAME (2014) INSPECTION1
06/15/2023240297460Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
10/27/2023240297460Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
06/15/2023240297460Open ↗
▸Approvals, Objections & Sign-offs7
▸BISLETTERS - SUPPORTING DOCUMENTATION3
05/25/2021240297460Open ↗
05/25/2021240297460Open ↗
05/25/2021240297460Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
06/08/2023240293400Open ↗
11/30/2022240293400Open ↗
▸BISSCHEDULE A - OCCUPANCY - USE2
05/25/2021240297460Open ↗
08/21/2023240297460Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT5
11/28/2022240293400Open ↗
11/09/2022240293400Open ↗
12/22/2021240297460Open ↗
Showing 3 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
12/21/2021240297460Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION3
04/08/2024240297460Open ↗
04/08/2024240297460Open ↗
05/25/2021240297460Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
05/25/2021240297460Open ↗
11/06/2020240293400Open ↗
▸Other Documents5
▸BISVIOLATIONS SEARCH1
12/21/2021240297460Open ↗
▸BISDOB NOW REVIEW COMPLETE1
12/21/2021240297460Open ↗
▸BISPLOT DIAGRAM1
05/25/2021240297460Open ↗
▸BISFOLDER REVIEW1
12/21/2021240297460Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
05/25/2021240297460Open ↗