← Back
Two family converted from one family
342 CARROLL STREET
BROOKLYN · BIN 3323394
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R6BZoning
2,796 sfGross Floor Area
2Units
Two family converted from one family · 2,323 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1 filing · 3 docs
Floor 1Under Construction1 filing · 3 docs
Sub-BasementUnder Construction1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THOMAS C. TUNG, P.E.108/10/2026
CQ&J CORPORATION107/29/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor108/01/2026
Building Lifecycle
All (39)Filed (2)Permit Issued (1)Objection (30)Special Inspection (6)
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Scope
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Other
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Admin
08/26/2026
Objection raised — Structural
08/26/2026
Objection raised — Fire_Protection
08/26/2026
Objection raised — Energy
08/26/2026
Objection raised — Fire_Protection
08/26/2026
Objection raised — Other
08/26/2026
Objection raised — Other
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Scope
08/26/2026
Objection raised — Admin
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Inspections
08/26/2026
Objection raised — Structural
08/26/2026
Objection raised — Scope
08/26/2026
Objection raised — Fire_Protection
08/26/2026
Objection raised — Structural
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Admin
08/26/2026
Objection raised — Structural
08/26/2026
Objection raised — Other
08/26/2026
Objection raised — Fire_Protection
08/26/2026
Objection raised — Scope
08/26/2026
Objection raised — Fire_Protection
08/26/2026
Objection raised — Admin
08/10/2026
Filed — Alteration CO
PROPOSED VERTIAL ENLARGEMENT ON EXISTING TWO(2) STORY WITH BASEMENT.OBTAIN NEW CERTIFICATE OF OCCUPANCY AS ONE(1) FAMILY RESIDENTIAL.
B01442029-I1
08/10/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/06/2026
Special inspection requirement — Structural Cold-Formed Steel
08/06/2026
Special inspection requirement — Structural Steel - Details
08/06/2026
Special inspection requirement — Energy Code Compliance Inspections
08/06/2026
Special inspection requirement — Final
07/31/2026
Permit issued — General Construction
B01431514-I1-GC
07/29/2026
Filed — Alteration
PARTIAL DEMOLITION ON EXISTING ONE(1) FAMILY,TWO(2) STORY FRAME RESIDENTIAL BUILDING WITH BASEMEANT.NO CHANGE OF BUILDING BULK,OCCUPANCY OR EGRESS.
B01431514-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMORELL BUILDERS INC07/31/2026
1 project · most recent 07/24/2026
General Wiring
FiledStatusContractorScope
07/24/2026Permit IssuedSolar Pro Electric Inc.General Wiring
1 project · most recent 08/10/2026
Steel Wood
FiledStatusContractorScope
08/10/2026——Steel, Wood
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
08/10/2026Structural Stability – Alterations of existing buildings—special
08/06/2026Fire-Resistant Penetrations and Joints—special
08/06/2026Structural Cold-Formed Steel—special
08/06/2026Structural Steel - Details—special
08/06/2026Energy Code Compliance Inspections—progress
08/06/2026Final—progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026B01431514-I1Request digital key ↗
08/16/2026B01442029-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026B01442029-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
09/28/2026B01442029-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
09/28/2026B01442029-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026B01431514-I1Open ↗
08/16/2026B01442029-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
09/28/2026B01442029-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/28/2026B01442029-I1Open ↗
08/16/2026B01431514-I1Open ↗
08/16/2026B01442029-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/16/2026B01442029-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/16/2026B01442029-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/16/2026B01442029-I1Open ↗
▸DOB NOWPlot Diagram1
09/28/2026B01442029-I1Open ↗