← Back
One story - permanent living quarter
3426 BOLLER AVENUE
BRONX · BIN 2072479
💬 Discuss this project
1958Year Built
1.5Stories
A2Building Class
R4AZoning
1,280 sfGross Floor Area
1Units
One story - permanent living quarter · Owner of record: PLAZA GARDENS REAL ESTATE CORP · 5,000 sf lot · 0.26 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21 filing · 20 docs
Floor 11 filing · 20 docs
Cellar1p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PLAZA HOMES103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/13/2019$320K—Private party → PLAZA GARDENS REAL ESTATE CORP$250/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PIROOZ ENGINEERING, P.C.909/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ROYAL T E203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION HOME DEV INCGeneral Contractor407/08/2026
J&J DESIGNS INCGeneral Contractor303/21/2026
DPH PLUMBING & HTG CORPPlumbing207/08/2026
C & A ELECTRICAL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PIROOZ ENGINEERING P.C7177405/07/2025
TRIANGLE INSPECTION & TES7495305/07/2025
Building Lifecycle
All (60)Filed (8)Permit Issued (5)Signed Off (2)Inspection (9)Objection (6)Special Inspection (30)
06/12/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/03/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/17/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Metering
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Maintenance information
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Air barrier - visual inspection
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — HVAC-R and service water heating equipment
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Interior lighting power
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — HVAC-R and service water heating system controls
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Fenestration air leakage
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Fenestration areas
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Insulation placement and R values
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Permanent certificate
PIROOZ SOLTANIZADEH
09/17/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
PIROOZ SOLTANIZADEH
09/11/2025
Filed — Alteration CO
CONVERSION OF AN EXIST. 1 1/2 STORY, 1 FAMILY FRAME BUILDING W/ CELLAR TO A 2 STORY, 2 FAMILY DWELLING WITH HORIZONTAL & VERTICAL EXTENSION.
X00516768-P3
08/19/2025
Filed — Alteration CO
CONVERSION OF AN EXIST. 1 1/2 STORY, 1 FAMILY FRAME BUILDING W/ CELLAR TO A 2 STORY, 2 FAMILY DWELLING WITH HORIZONTAL & VERTICAL EXTENSION.
X00516768-P2
06/02/2025
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALTERATION CO APPLICATION # X00516768
X00567205-I1
05/14/2025
Permit issued — Plumbing
X00567205-I1-PL
05/08/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
PIROOZ SOLTANIZADEH
05/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PIROOZ SOLTANIZADEH
05/08/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
05/08/2025
Special inspection requirement — Energy Code Compliance Inspections
PIROOZ SOLTANIZADEH
05/08/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PIROOZ SOLTANIZADEH
05/08/2025
Special inspection requirement — HVAC-R and service water heating system controls
PIROOZ SOLTANIZADEH
05/08/2025
Special inspection requirement — HVAC-R and service water heating equipment
PIROOZ SOLTANIZADEH
05/07/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALTERATION CO APPLICATION # X00516768
X00567205-P2
05/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PIROOZ SOLTANIZADEH
05/06/2025
Special inspection requirement — HVAC-R and service water heating equipment
PIROOZ SOLTANIZADEH
05/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PIROOZ SOLTANIZADEH
05/06/2025
Special inspection requirement — HVAC-R and service water heating system controls
PIROOZ SOLTANIZADEH
05/06/2025
Special inspection requirement — Energy Code Compliance Inspections
PIROOZ SOLTANIZADEH
05/06/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
05/06/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
PIROOZ SOLTANIZADEH
04/24/2025
Signed off — Alteration
CONSTRUCTION FENCE APPLICATION FILED IN CONJUNCTION WITH ALTERATION CO APPLICATION # X00516768-I1
X00567159-I1
04/16/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALTERATION CO APPLICATION # X00516768
X00567205-P1
04/15/2025
Special inspection requirement — HVAC-R and service water heating equipment
PIROOZ SOLTANIZADEH
04/15/2025
Special inspection requirement — HVAC-R and service water heating system controls
PIROOZ SOLTANIZADEH
04/15/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PIROOZ SOLTANIZADEH
03/20/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
03/20/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/29/2025
Filed — Alteration CO
CONVERSION OF AN EXIST. 1 1/2 STORY, 1 FAMILY FRAME BUILDING W/ CELLAR TO A 2 STORY, 2 FAMILY DWELLING WITH HORIZONTAL & VERTICAL EXTENSION.
X00516768-P1
06/12/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/14/2024
Permit issued — Plumbing
X00567205-I1-PL
12/29/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/19/2023
Permit issued — General Construction
X00516768-I1-GC
11/02/2023
Permit issued — General Construction
X00516768-I1-GC
11/02/2023
Permit issued — Construction Fence
X00567159-I1-FN
01/03/2022
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH ALTERATION CO APPLICATION # X00516768
X00567205-I1
01/03/2022
Filed — Alteration
CONSTRUCTION FENCE APPLICATION FILED IN CONJUNCTION WITH ALTERATION CO APPLICATION # X00516768-I1
X00567159-I1
08/17/2021
Objection raised — Zoning
08/17/2021
Objection resolved — Addressed
08/17/2021
Objection raised — Structural
08/17/2021
Objection resolved — Addressed
06/15/2021
Objection raised — Scope
06/15/2021
Objection resolved — Addressed
05/28/2021
Filed — Alteration CO
CONVERSION OF AN EXIST. 1 1/2 STORY, 1 FAMILY FRAME BUILDING W/ CELLAR TO A 2 STORY, 2 FAMILY DWELLING WITH HORIZONTAL & VERTICAL EXTENSION.
X00516768-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP05/14/2025
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP05/14/2024
DOB NOWGeneral ConstructionPermit IssuedPRECISION HOME DEV INC12/19/2023
DOB NOWGeneral ConstructionPermit IssuedJ&J DESIGNS INC11/02/2023
DOB NOWConstruction FenceSigned-offPRECISION HOME DEV INC11/02/2023
1 project
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
———Heating Systems, Ventilation Systems
Ventilation
1 project · most recent 02/03/2024
General Wiring
FiledStatusContractorScope
02/03/2024CompleteC & A ELECTRICAL CORPGeneral Wiring
1 project
FiledStatusContractorScope
———2 scope_items
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
06/12/2026Pass-Final CND-Occupancy InspectionPassView ↗
11/03/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/20/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/20/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/12/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/12/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/12/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/29/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
09/17/2025HVAC-R and service water piping design and insulationPIROOZ SOLTANIZADEHenergy_progress
09/17/2025MeteringPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Maintenance informationPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Air barrier - visual inspectionPIROOZ SOLTANIZADEHenergy_progress
09/17/2025HVAC-R and service water heating equipmentPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Interior lighting powerPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Structural Stability – Alterations of existing buildingsPIROOZ SOLTANIZADEHspecial
09/17/2025HVAC-R and service water heating system controlsPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Fenestration air leakagePIROOZ SOLTANIZADEHenergy_progress
09/17/2025Fenestration areasPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Insulation placement and R valuesPIROOZ SOLTANIZADEHenergy_progress
09/17/2025Permanent certificatePIROOZ SOLTANIZADEHenergy_progress
09/17/2025Fenestration and door U-factor and product ratingsPIROOZ SOLTANIZADEHenergy_progress
05/08/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationPIROOZ SOLTANIZADEHspecial
05/08/2025Fire-Resistant Penetrations and JointsPIROOZ SOLTANIZADEHspecial
05/08/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
05/08/2025Energy Code Compliance InspectionsPIROOZ SOLTANIZADEHprogress
05/08/2025HVAC-R and service water piping design and insulationPIROOZ SOLTANIZADEHenergy_progress
05/08/2025HVAC-R and service water heating system controlsPIROOZ SOLTANIZADEHenergy_progress
05/08/2025HVAC-R and service water heating equipmentPIROOZ SOLTANIZADEHenergy_progress
05/06/2025Fire-Resistant Penetrations and JointsPIROOZ SOLTANIZADEHspecial
05/06/2025HVAC-R and service water heating equipmentPIROOZ SOLTANIZADEHenergy_progress
05/06/2025HVAC-R and service water piping design and insulationPIROOZ SOLTANIZADEHenergy_progress
05/06/2025HVAC-R and service water heating system controlsPIROOZ SOLTANIZADEHenergy_progress
05/06/2025Energy Code Compliance InspectionsPIROOZ SOLTANIZADEHprogress
Latest 25 of 34.
▾Documents — 73 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/24/2026X00567159-I1Request digital key ↗
08/19/2026X00567205-I1Request digital key ↗
08/19/2026X00567205-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records10
▸DOB NOWZD1: DOB Zoning Diagram4
08/18/2026X00516768-P2Open ↗
08/18/2026X00516768-P3Open ↗
08/18/2026X00516768-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)3
08/18/2026X00516768-P3Open ↗
08/18/2026X00516768-P2Open ↗
08/15/2026X00516768-I1Open ↗
▸DOB NOWRestrictive Declaration/Easement 11
08/18/2026X00516768-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026X00516768-I1Open ↗
▸DOB NOWRestrictive Declaration/Easement 21
08/18/2026X00516768-P1Open ↗
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature9
08/29/2026X00516768-I1Open ↗
08/29/2026X00516768-I1Open ↗
08/29/2026X00516768-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/29/2026X00516768-I1Open ↗
08/28/2026X00567205-P1Open ↗
08/28/2026X00567205-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/19/2026X00567205-P1Open ↗
08/19/2026X00567205-P2Open ↗
08/19/2026X00567205-I1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist4
08/18/2026X00516768-P3Open ↗
08/18/2026X00516768-P1Open ↗
08/18/2026X00516768-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStreet Tree Sign Off1
08/15/2026X00516768-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/15/2026X00516768-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/19/2026X00567205-P1Open ↗
08/19/2026X00567205-P2Open ↗
08/19/2026X00567205-I1Open ↗
Showing 3 of 7 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/15/2026X00516768-I1Open ↗
08/13/2026X00567205-I1Open ↗
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT4
08/18/2026X00516768-P2Open ↗
08/18/2026X00516768-P1Open ↗
08/18/2026X00516768-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Plot Diagram1
08/15/2026X00516768-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/15/2026X00516768-I1Open ↗
▸Other Documents13
▸DOB NOWSite Survey: Initial4
08/18/2026X00516768-P3Open ↗
08/18/2026X00516768-P2Open ↗
08/18/2026X00516768-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/18/2026X00516768-P3Open ↗
08/18/2026X00516768-P2Open ↗
08/18/2026X00516768-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/18/2026X00516768-P1Open ↗
08/18/2026X00516768-P3Open ↗
08/18/2026X00516768-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/15/2026X00516768-I1Open ↗