| Owner | Filings | Most Recent |
|---|---|---|
| NYC School Construction Authority | 8 | 10/15/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Hartland Engineering | 3 | 10/14/2026 |
| IMEG Consultants | 3 | 10/14/2026 |
| Ysrael A. Seinuk | 1 | 10/14/2026 |
| DI Domenico + Partners | 1 | 10/13/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/14/2026 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Annexair AHU-E-12-D-SS-CO-2-S-T 11,150 CFM · Ahu ×1 ERU-E-12-EW07-D-SS-CO-2-S-T 255,000 BTU · Ahu ×1 ERU-E-16-EW07-D-SS-CO-2-S-T 282,000 BTU · Ahu ×1 Aermec NYG0500XK°°J9002 29 tons · Chiller ×1 Ventilation Loren Cook ACED-EC, Catalog No. 90C17DEC 345 CFM · Exhaust Fan ×2 ACE-D VF 500 CFM · Exhaust Fan ×1 ACE-D VF ( Catalog No. 100C17DH (VF)) 500 CFM · Exhaust Fan ×1 ACE-D VF ( Catalog No. 101C17DOR70VF ) 250 BTU · Exhaust Fan ×1 ACE-D VF, Catalog No. 101C17DOR60VF 100 CFM · Exhaust Fan ×1 ACE-D VF, Catalog No. 100C17DM (VF) 375 CFM · Exhaust Fan ×1 ACE-D VF, Catalog No. 165C17D (VF) 3,675 CFM · Exhaust Fan ×1 ACED-EC ( Catalog No. 90C17DEC) 300 CFM · Exhaust Fan ×1 ACED-EC, Catalog No. 100C17DEC 405 CFM · Exhaust Fan ×1 ACED-EC, Catalog No. 270VX11B 3,000 CFM · Exhaust Fan ×1 ACSC-XP, Catalog No. 270VX11B 4,472 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/14/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/14/2026 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/14/2026 | — | — | Steel, Concrete |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/14/2026 | Shutoff dampers | — | energy_progress |
| 10/14/2026 | Fenestration air leakage | — | energy_progress |
| 10/14/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 10/14/2026 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | — | special |
| 10/14/2026 | Post-installed Anchors | — | special |
| 10/14/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 10/14/2026 | Air barrier - visual inspection | — | energy_progress |
| 10/14/2026 | Insulation placement and R values | — | energy_progress |
| 10/14/2026 | Fenestration areas | — | energy_progress |
| 10/14/2026 | Fenestration air leakage | — | energy_progress |
| 10/14/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 10/14/2026 | Chimneys and vents | — | special |
| 10/14/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 10/14/2026 | Heating Systems | — | special |
| 10/14/2026 | Post-installed Anchors | — | special |
| 10/14/2026 | Mechanical Systems | — | special |
| 10/14/2026 | Final | — | progress |
| 10/14/2026 | Energy Code Compliance Inspections | — | progress |
| 10/14/2026 | HVAC-R and service water heating equipment | — | energy_progress |
| 10/14/2026 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 10/14/2026 | HVAC-R and service water heating system controls | — | energy_progress |
| 10/14/2026 | Fenestration areas | — | energy_progress |
| 10/14/2026 | Air barrier - visual inspection | — | energy_progress |
| 10/14/2026 | Insulation placement and R values | — | energy_progress |
| 10/13/2026 | Subsurface Investigations (Borings/Test Pits) | — | special |