← Back
Elevator apt, semi-fireproof without stores
Eastchester Heights
3437 EASTCHESTER ROAD · BIN 2117012
💬 Discuss this project
1935Year Built
6Stories
D1Building Class
R6Zoning
254,000 sfGross Floor Area
326Units
LL97 CoveredRent Stabilized738 Open Violations 734 unresolved · 4 paperwork only ▸
Elevator apt, semi-fireproof without stores · Owner of record: EASTCHESTER HEIGHTS HOUSING DEVELOPMENT FUND CORPO · 108,066 sf lot · 2.35 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CREW CONTRACTING OF NJ1007/08/2026
EASTCHESTER HEIGHTS PROPERTY OWNER LLC403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOEL PHAGOO P.E. PLLC108/23/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS103/21/2026
A1 EXPEDITING SERVICE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YARKS NYC INCGeneral Contractor907/08/2026
SANKAR SHILElectrical103/21/2026
Building Lifecycle
All (70)Filed (2)Permit Issued (6)Signed Off (2)Violation (60)
05/08/2026
Violation issued (HPD, closed)
A
02/21/2026
Violation issued (HPD, open)
B
02/21/2026
Violation issued (HPD, open)
C
02/21/2026
Violation issued (HPD, closed)
C
02/21/2026
Violation issued (HPD, open)
C
01/24/2026
Violation issued (HPD, closed)
C
01/24/2026
Violation issued (HPD, open)
C
01/24/2026
Violation issued (HPD, open)
C
01/24/2026
Violation issued (HPD, closed)
C
01/24/2026
Violation issued (HPD, open)
C
01/24/2026
Violation issued (HPD, open)
B
01/24/2026
Violation issued (HPD, closed)
A
01/24/2026
Violation issued (HPD, open)
C
01/24/2026
Violation issued (HPD, closed)
C
01/21/2026
Violation issued (HPD, open)
C
12/08/2025
Violation issued (HPD, open)
B
11/20/2025
Signed off — Alteration
Installation of suspended scaffold for facade repair & inspection.
X01205339-I1
09/18/2025
Violation issued (HPD, closed)
C
09/18/2025
Violation issued (HPD, closed)
A
09/18/2025
Violation issued (HPD, closed)
B
09/18/2025
Violation issued (HPD, closed)
C
09/18/2025
Violation issued (HPD, closed)
B
09/18/2025
Violation issued (HPD, closed)
A
09/18/2025
Violation issued (HPD, closed)
C
09/18/2025
Violation issued (HPD, closed)
C
09/18/2025
Violation issued (HPD, closed)
C
09/18/2025
Violation issued (HPD, closed)
B
09/18/2025
Violation issued (HPD, closed)
C
09/18/2025
Violation issued (HPD, closed)
B
04/15/2025
Permit issued — Suspended Scaffold
X01205339-I1-SC
04/10/2025
Violation issued (HPD, closed)
C
04/10/2025
Violation issued (HPD, closed)
C
04/07/2025
Violation issued (HPD, closed)
C
04/07/2025
Violation issued (HPD, closed)
C
04/07/2025
Violation issued (HPD, closed)
C
04/03/2025
Filed — Alteration
Installation of suspended scaffold for facade repair & inspection.
X01205339-I1
03/24/2025
Violation issued (HPD, closed)
B
03/24/2025
Violation issued (HPD, closed)
C
03/04/2025
Violation issued (HPD, closed)
I
02/04/2025
Violation issued (HPD, closed)
A
01/31/2025
Violation issued (HPD, closed)
I
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
B
12/08/2024
Violation issued (HPD, closed)
B
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
B
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
B
12/08/2024
Violation issued (HPD, closed)
B
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
B
12/08/2024
Violation issued (HPD, closed)
C
12/08/2024
Violation issued (HPD, closed)
C
12/05/2024
Violation issued (HPD, closed)
B
12/05/2024
Violation issued (HPD, closed)
B
12/05/2024
Violation issued (HPD, closed)
B
Latest 60 of 70 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldSigned-offHONEYBEE SERVICES INC04/15/2025
DOB NOWSidewalk ShedSigned-offYARKS NYC INC11/04/2020
DOB NOWSidewalk ShedSigned-offYARKS NYC INC02/21/2020
DOB NOWSidewalk ShedSigned-offYARKS NYC INC02/08/2019
DOB NOWSidewalk ShedSigned-offYARKS NYC INC01/11/2019
DOB NOWSidewalk ShedSigned-offYARKS NYC INC08/25/2018
BISOTISSUEDRAINIER RESTORATION LLC08/26/2021
BISOTISSUEDRAINIER RESTORATION LLC07/21/2021
BISOTISSUEDRAINIER RESTORATION LLC09/12/2019
1 project · most recent 08/08/2018
FiledStatusContractorScope
08/08/2018CompleteGREEN POWER ELECTRIC CORP—
Nothing on file for this building.
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026X00073182-I1Request digital key ↗
08/19/2026X01205339-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
04/18/2019220699536Open ↗
▸BISWORK PERMIT APPLICATION1
09/17/2019220699536Open ↗
▸Seals & Professional Certifications3
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
09/09/2019220699536Open ↗
04/18/2019220699536Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X00073182-I1Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
04/18/2019220699536Open ↗
▸Energy Compliance2
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/10/2022220699536Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/18/2019220699536Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/10/2022220699536Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/13/2022220699536Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
08/26/2019220699536Open ↗
04/18/2019220699536Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
06/10/2022220699536Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/18/2019220699536Open ↗
▸Other Documents2
▸DOB NOWManufacturer's Specifications1
08/13/2026X01205339-I1Open ↗
▸DOB NOWCalculations1
08/13/2026X01205339-I1Open ↗