← Back
Miscellaneous one family
345 BERRY STREET
BROOKLYN · BIN 3063423
💬 Discuss this project
1899Year Built
2Stories
A9Building Class
M1-2/R6Zoning
1,092 sfGross Floor Area
1Units
3 Open Violations ▸FDNY Report ↗
Miscellaneous one family · Owner of record: 345 BERRY STREET LLC · 933 sf lot · 1.17 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction19p · 2 filings · 20 docs
Floor 2Under Construction17p · 1 filing · 20 docs
Floor 1Under Construction16p · 1 filing · 20 docs
CellarUnder Construction21p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
345-45 BERRY ST REALTY LL103/22/2026
DOCE CAP BERRY LLC103/22/2026
SKYWARD DEVELOPERS203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/20/2023$1.5M—343 BERRY LLC → 345 BERRY STREET LLC$1,374/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENGINEERING CONSULTING SERVICES707/29/2026
VASILIOS ARTEMIOU PE205/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEVM EXPEDITORS1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION BUILD USA INCGeneral Contractor708/07/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050403/23/2026
Building Lifecycle
All (129)Filed (9)Permit Issued (7)Violation (5)Objection (78)Special Inspection (30)
08/06/2026
Permit issued — Construction Fence
B01057158-S6-FN
08/04/2026
Objection resolved — Addressed
07/30/2026
Objection raised — Other
07/29/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR UNDERPINNING EXCAVATION WORK ON EXISTING FOUNDATION, TO RESOLVE ECB VIOLATION:39112783P,
B01057158-S6
07/17/2026
Objection resolved — Addressed
07/17/2026
Objection resolved — Resolved
07/17/2026
Objection resolved — Resolved
07/17/2026
Objection resolved — Addressed
06/26/2026
Objection resolved — Addressed
06/26/2026
Objection resolved — Addressed
06/09/2026
Objection resolved — Addressed
04/22/2026
Objection resolved — Addressed
04/02/2026
Objection raised — Cost
04/02/2026
Objection raised — Admin
04/02/2026
Objection raised — Scope
04/02/2026
Objection raised — Other
04/02/2026
Objection raised — Energy
04/02/2026
Objection raised — Zoning
04/02/2026
Objection raised — Admin
04/02/2026
Objection raised — Scope
03/24/2026
Permit issued — General Construction
B01057158-I1-GC
03/23/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR UNDERPINNING EXCAVATION WORK ON EXISTING FOUNDATION, TO RESOLVE ECB VIOLATION:39112783P,
B01057158-P1
03/20/2026
Permit issued — Structural
B01057158-S2-ST
03/20/2026
Permit issued — Foundation
B01057158-S3-FO
03/16/2026
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
03/16/2026
Special inspection requirement — Fenestration areas
PAUL MARINO
03/16/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
PAUL MARINO
03/16/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
PAUL MARINO
03/16/2026
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
03/16/2026
Special inspection requirement — Air barrier — testing
PAUL MARINO
03/16/2026
Special inspection requirement — Permanent certificate
PAUL MARINO
03/16/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
03/16/2026
Special inspection requirement — Fenestration air leakage
PAUL MARINO
03/16/2026
Special inspection requirement — Interior lighting power
PAUL MARINO
03/16/2026
Special inspection requirement — Insulation placement and R values
PAUL MARINO
12/29/2025
Permit issued — General Construction
B01057158-I1-GC
12/29/2025
Permit issued — Foundation
B01057158-S3-FO
12/29/2025
Permit issued — Structural
B01057158-S2-ST
09/18/2025
Objection raised — Zoning
09/18/2025
Objection resolved — Addressed
07/07/2025
Objection raised — Other
07/07/2025
Objection resolved — Addressed
07/07/2025
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
07/07/2025
Special inspection requirement — Air barrier — testing
PAUL MARINO
07/07/2025
Special inspection requirement — Permanent certificate
PAUL MARINO
06/04/2025
Objection raised — Scope
06/04/2025
Objection resolved — Addressed
05/15/2025
Objection resolved — Addressed
05/15/2025
Special inspection requirement — Structural Steel - Details
PAUL MARINO
05/14/2025
Special inspection requirement — Structural Cold-Formed Steel
PAUL MARINO
05/06/2025
Objection raised — Structural
05/06/2025
Objection resolved — Addressed
05/06/2025
Objection raised — Other
05/06/2025
Objection resolved — Addressed
04/28/2025
Objection resolved — Addressed
04/28/2025
Objection resolved — Addressed
04/28/2025
Objection resolved — Addressed
04/28/2025
Objection resolved — Addressed
04/08/2025
Objection raised — Structural
04/08/2025
Objection raised — Other
Latest 60 of 129 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedPRECISION BUILD USA INC08/06/2026
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILD USA INC03/24/2026
DOB NOWStructuralPermit IssuedPRECISION BUILD USA INC03/20/2026
DOB NOWFoundationPermit IssuedPRECISION BUILD USA INC03/20/2026
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILD USA INC12/29/2025
DOB NOWFoundationPermit IssuedPRECISION BUILD USA INC12/29/2025
DOB NOWStructuralPermit IssuedPRECISION BUILD USA INC12/29/2025
1 project · most recent 05/08/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/08/2024——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin PUY-A36NKA7 36,000 BTU · Heat Pump Outdoor ×1
PUY-A42NKA7 42,000 BTU · Heat Pump Outdoor ×1
Ventilation
Nutone AEN110 50 CFM · Exhaust Fan ×3
QTXE110150DC 100 CFM · Kitchen Exhaust ×1
1 project · most recent 05/08/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/08/2024——Gas, Storm, Water/Sanitary
1 project · most recent 07/29/2026
Steel Concrete
FiledStatusContractorScope
07/29/2026Permit IssuedPRECISION BUILD USA INCSteel, Concrete
1 project · most recent 07/29/2026
Fence
FiledStatusContractorScope
07/29/2026Permit IssuedPRECISION BUILD USA INCFence
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
03/16/2026Air barrier - visual inspectionPAUL MARINOenergy_progress
03/16/2026Fenestration areasPAUL MARINOenergy_progress
03/16/2026Exterior Insulation and Finish Systems (EIFS)PAUL MARINOspecial
03/16/2026Structural Stability – Alterations of existing buildingsPAUL MARINOspecial
03/16/2026Energy Code Compliance InspectionsPAUL MARINOprogress
03/16/2026Air barrier — testing PAUL MARINOenergy_progress
03/16/2026Permanent certificatePAUL MARINOenergy_progress
03/16/2026Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
03/16/2026Fenestration air leakagePAUL MARINOenergy_progress
03/16/2026Interior lighting powerPAUL MARINOenergy_progress
03/16/2026Insulation placement and R valuesPAUL MARINOenergy_progress
07/07/2025Air barrier - visual inspectionPAUL MARINOenergy_progress
07/07/2025Air barrier — testing PAUL MARINOenergy_progress
07/07/2025Permanent certificatePAUL MARINOenergy_progress
05/15/2025Structural Steel - DetailsPAUL MARINOspecial
05/14/2025Structural Cold-Formed SteelPAUL MARINOspecial
02/05/2025Structural Stability – Alterations of existing buildingsPAUL MARINOspecial
01/28/2025Post-installed AnchorsPAUL MARINOspecial
01/28/2025Concrete - Cast-In-PlacePAUL MARINOspecial
06/25/2024Insulation placement and R valuesPAUL MARINOenergy_progress
06/24/2024Designated Seismic SystemPAUL MARINOspecial
06/24/2024FinalShahrish Shuvoprogress
05/27/2024Interior lighting powerPAUL MARINOenergy_progress
05/27/2024Fenestration areasPAUL MARINOenergy_progress
05/27/2024Fenestration air leakagePAUL MARINOenergy_progress
Latest 25 of 51.
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/25/2026B01021528-S1Request digital key ↗
08/25/2026B01021528-I1Request digital key ↗
08/17/2026B01057158-S3Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits3
▸DOB NOWHPD Certification Letter or CPC Special Permit3
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-I1Open ↗
08/13/2026B01021528-I1Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram3
08/17/2026B01057158-P1Open ↗
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B01057158-I1Open ↗
08/13/2026B01057158-P1Open ↗
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/25/2026B01021528-I1Open ↗
08/25/2026B01021528-S2Open ↗
08/25/2026B01021528-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/31/2026B01057158-P1Open ↗
08/31/2026B01057158-P1Open ↗
08/26/2026B01057158-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/31/2026B01057158-P1Open ↗
08/31/2026B01057158-P1Open ↗
08/26/2026B01057158-S2Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist4
08/13/2026B01057158-I1Open ↗
08/13/2026B01240538-P1Open ↗
08/13/2026B01240538-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWCertificate of No Harassment3
08/13/2026B01021528-I1Open ↗
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026B01057158-S2Open ↗
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-I1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports2
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/13/2026B01057158-S3Open ↗
08/13/2026B01057158-S1Open ↗
▸Other Documents12
▸DOB NOWSite Survey: Initial4
08/13/2026B01057158-I1Open ↗
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram3
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-S3Open ↗
08/13/2026B01057158-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026B01057158-P1Open ↗
08/13/2026B01057158-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B01057158-I1Open ↗