| Owner | Filings | Most Recent |
|---|---|---|
| Urban Health Plan | 21 | 06/27/2026 |
| Castle Construction and Maintenance | 5 | 03/22/2026 |
| Paragon | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 11/17/2021 | $3.6M | — | SV PENINSULA LLC → Urban Health Plan | $300/sf building |
| 02/07/2017 | $2.6M | — | P&P HOLDING,LLC → SV PENINSULA LLC | $219/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Twig NJ Engineers | 4 | 10/02/2025 |
| Arquitectura Varela | 1 | 12/18/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| Richard Montana, Architect | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| City Grid Electric | Electrical | 8 | 03/21/2026 |
| CCM Services Group | General Contractor | 8 | 04/08/2026 |
| CCM Services Group | Scaffold | 3 | 03/21/2026 |
| Hydrokinetic Plumbing & Heating I | Plumbing | 2 | 06/27/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Quality Control Laborator | 406 | 4 | 10/02/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | Hydrokinetic Plumbing & Heating I | 05/06/2026 |
| DOB NOW | Mechanical Systems | Signed-off | CCM Services Group | 07/10/2025 |
| DOB NOW | General Construction | Signed-off | CCM Services Group | 07/10/2025 |
| DOB NOW | Plumbing | Signed-off | Hydrokinetic Plumbing & Heating I | 01/09/2025 |
| DOB NOW | General Construction | Signed-off | CCM Services Group | 06/06/2024 |
| DOB NOW | General Construction | Signed-off | CCM Services Group | 06/05/2024 |
| DOB NOW | Supported Scaffold | Signed-off | CCM Services Group | 01/24/2024 |
| DOB NOW | Mechanical Systems | Signed-off | CCM Services Group | 09/15/2023 |
| DOB NOW | General Construction | Signed-off | CCM Services Group | 09/15/2023 |
| BIS | SP | ISSUED | Anesis Services | 11/25/2025 |
| BIS | — | ISSUED | CCM Services Group | 11/15/2021 |
| BIS | SP | ISSUED | Pat Sementa P&H Co | 12/16/2020 |
| BIS | OT | ISSUED | Paragon Building Restoration | 10/19/2018 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/02/2025 | Signed-off | CCM Services Group | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric AC-1: PLFY-EP36NEMU-E
AC-3: PLFY-EP36NEMU-E
AC-5: PLFY-EP36NEMU-E
AC-7: PLFY-EP36NEMU-E 3 tons · Vrf Indoor ×8 AC-2: PLFY-EP36NEMU-E AC-4: PLFY-EP36NEMU-E AC-6: PLFY-EP36NEMU-E AC-8: PLFY-EP36NEMU-E 3 tons · Vrf Indoor ×8 AC-9: PLFY-EP36NEMU-E AC-10: PLFY-EP36NEMU-E AC-11: PLFY-EP36NEMU-E 3 tons · Vrf Indoor ×6 MXZ-SM36NAMHZ-U1 1 tons · Condensing Unit ×2 PKFY-P08NHMU 18,000 BTU · Vrf Indoor ×1 PLFY-P08NFMU-E 8,000 BTU · Vrf Indoor ×2 PLFY-P12NFMU-E 1 tons · Vrf Indoor ×2 PLFY-P18NFMU-E 15 tons · Vrf Indoor ×2 PUHY-HP96TNU-A 8 tons · Vrf Outdoor ×1 PUHY-P144TNU-A 1 tons · Vrf Outdoor ×2 TUHYP1443AN40AN 12 tons · Condensing Unit ×2 PLFY-EP36NEMU-E PLFY-EP36NEMU-E PLFY-EP36NEMU-E AC-7: PLFY-EP36NEMU-E 3 tons · Vrf Indoor ×4 PLFY-EP36NEMU-E PLFY-EP36NEMU-E PLFY-EP36NEMU-E PLFY-EP36NEMU-E 3 tons · Vrf Indoor ×4 PLFY-EP36NEMU-E PLFY-EP36NEMU-E PLFY-EP36NEMU-E 3 tons · Vrf Indoor ×3 Ventilation Greenheck QEID-16 2,800 CFM · Exhaust Fan ×2 QEID-20 7,400 CFM · Exhaust Fan ×2 SP-B110 75 CFM · Exhaust Fan ×2 Mitsubishi Electric TLGHF0940RVX02A 940 CFM · Erv ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/02/2025 | Signed-off | Hydrokinetic Plumbing & Heating I | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/17/2025 | Complete | City Grid Electric | 1 meters, 1 new_meters |
| 06/17/2025 | Complete | City Grid Electric | General Wiring |
| 07/17/2023 | Cancelled | Lintech Electric | 1 meters, 1 new_meters |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/06/2025 | Emergency and Standby Power Systems (Generator) | EDWIN DEGUZMAN | special |
| 10/06/2025 | Fire-Resistant Penetrations and Joints | SAMUEL BAUTISTA | special |
| 10/06/2025 | Mechanical Systems | EDWIN DEGUZMAN | special |
| 10/06/2025 | Energy Code Compliance Inspections | EDWIN DEGUZMAN | progress |
| 10/06/2025 | Final | EDWIN DEGUZMAN | progress |
| 10/06/2025 | HVAC-R and service water heating system controls | EDWIN DEGUZMAN | energy_progress |
| 10/06/2025 | HVAC-R and service water piping design and insulation | EDWIN DEGUZMAN | energy_progress |
| 10/06/2025 | Interior lighting power | EDWIN DEGUZMAN | energy_progress |
| 10/06/2025 | Duct leakage testing, insulation and design | EDWIN DEGUZMAN | energy_progress |
| 10/06/2025 | Lighting controls | EDWIN DEGUZMAN | energy_progress |
| 10/06/2025 | HVAC-R and service water heating equipment | EDWIN DEGUZMAN | energy_progress |
| 04/10/2025 | Fire-Resistant Penetrations and Joints | SAMUEL BAUTISTA | special |
| 04/10/2025 | Energy Code Compliance Inspections | EDWIN DEGUZMAN | progress |
| 03/25/2025 | Emergency and Standby Power Systems (Generator) | EDWIN DEGUZMAN | special |
| 03/25/2025 | Fire-Resistant Penetrations and Joints | SAMUEL BAUTISTA | special |
| 03/25/2025 | Mechanical Systems | EDWIN DEGUZMAN | special |
| 03/25/2025 | Energy Code Compliance Inspections | EDWIN DEGUZMAN | progress |
| 03/25/2025 | Final | EDWIN DEGUZMAN | progress |
| 03/25/2025 | HVAC-R and service water heating equipment | EDWIN DEGUZMAN | energy_progress |
| 03/25/2025 | Duct leakage testing, insulation and design | EDWIN DEGUZMAN | energy_progress |
| 03/25/2025 | Interior lighting power | EDWIN DEGUZMAN | energy_progress |
| 03/25/2025 | Lighting controls | EDWIN DEGUZMAN | energy_progress |
| 03/25/2025 | HVAC-R and service water heating system controls | EDWIN DEGUZMAN | energy_progress |
| 03/25/2025 | HVAC-R and service water piping design and insulation | EDWIN DEGUZMAN | energy_progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Urban Health Plan | Medical / Healthcare | Floor 1, Roof | Project X00898189 |