ECB02/09/2022Unlawful acts.fail to comply with an order of commissioner.fail to correct and certify ECB#35343154P-no gfci provided outdoor ECB#35343155R-fixable metal conduit more than 6 ft ECB#35343150H-failure to ground,n$12K due
ECB12/21/2021Unlawful acts.failure to comply with an order of the commissioner.failure to correct and certify summons ECB#35343950H;ECB#35343154P and ECB#35343156Z.unapproved,unsafe,unsuitable electrical equipment apparatus$12K due
ECB09/23/2021Failure to comply with the commissioner's order summons 35343150H and 35343155R still remains, comply with commissioner's order; comply with code$12K due
ECB11/06/2021Unlawful acts. Failure to comply w/ an order of the commissioner. Failure to correct and certify summons#35343150H no water main ground,summons#35343151J gec is not of proper size,summons#35343154P outdoors andNothing owed — awaiting certificate of correction
ECB05/21/2019Failure to comply w/ commissioner's order contained in summons/violation#35343248X issued on 8/6/18,and to file a certificate of correction pursuant to 28.201.1 and 1RCNY 102-01(d)(2). An acceptable certificateNothing owed — awaiting certificate of correction
ECB10/05/2018Fail to provide/maintain sufficient access/workspace about electrical equipment.min clearance is not provided in front of electrical panels in kitchen elect area.rem:provide/maintain access/work spaceNothing owed — awaiting certificate of correction
ECB10/05/2018350.12.3.amendment.flexible metal conduit feeding outdoor ac unit behind bak is more than 6FT.rem:comply with ec code.must file an electrical applicationNothing owed — awaiting certificate of correction
ECB10/05/2018Unapproved/unsafe/unsuitable electrical equipment apparatus,materials,devices,appliances or wiring in use.emt used outdoor to supply power to women locker room.rem:comply with ec code must file an electrical apNothing owed — awaiting certificate of correction
ECB10/05/2018Table 250.66.grounding conductor at 400 ser sw is not of proper size #8 bare solid conductor use for ser entrnace conductor 500 inch grounding conductor is not as per table.rem:comply with ec code must file anNothing owed — awaiting certificate of correction
ECB10/05/2018Failure to ground electrical system.no water main ground is provided at water main for you a senswis.rem:provide grounding.must file an electrical applicationNothing owed — awaiting certificate of correction
ECB10/05/2018210.8.b.gfci is not provided for outlets outdoor and outdoor baks entire grounds outdoor area,rec area,women locker room,sheds.rem:comply with ec code must file an electrical applicationNothing owed — awaiting certificate of correction
ECB10/05/2018Unapproved/unsafe/unsuitable electrical equipment apparatus,materials,device appliances or wiring in use,flexible cord used as permanent wiring outdoor flexible cord used as permanent wiring outdoor feeding fasNothing owed — awaiting certificate of correction
ECB08/06/2018Unapproved/unsafe/unsuitable/electrical equipments,apparatus,materials,devices,apparatus or wiring in use.externsion cords & fixture/zip cords used as permenant wiring throughout.rem:comply w/ec code/obtain perNothing owed — awaiting certificate of correction
ECB07/24/2018GFC503.4.1.misc violations use of approved maintain.on the above mentioned date i observed pvc piping being used to vent 2 hot water heatersat this property which is not permitted as per the code.rem:comply wiNothing owed — awaiting certificate of correction
ECB07/24/2018Work without a permit.at the time of my inspection i observed the installation of mobile bathroom at the rear of the establishment i also observed that these bathrooms had pvc piping used for the waste lines iNothing owed — awaiting certificate of correction
ECB07/24/2018Failure to maintain building in a code compliant manner.failure to comply with law for drainage system per 702.1;27-911;the above mention date i observed the use of pvc piping used throughout premises.the pipinNothing owed — awaiting certificate of correction