| Owner | Filings | Most Recent |
|---|---|---|
| EDMUND LEWIS CONTRACTING | 4 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/19/2024 | $3.3M | — | — → — | $910/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ERIC K. DANIELS ARCHITECT, PC | 6 | 04/13/2026 |
| OLD STRUCTURES ENGINEERING | 2 | 01/28/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| SOL BUILDING CONSULTING SERVICES | 7 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CITY LINE INTERIORS INC | General Contractor | 3 | 04/09/2026 |
| ETHOS PLUMBING CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ERIC K. DANIELS ARCHITECT | 4060 | 4 | 02/18/2026 |
| CHEN ENGINEERING SERVICES | 1826 | 1 | 09/29/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Permit Issued | CITY LINE INTERIORS | 03/20/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | CITY LINE INTERIORS | 12/02/2025 |
| DOB NOW | Plumbing | Permit Issued | ETHOS PLUMBING CORP | 11/13/2025 |
| DOB NOW | General Construction | Permit Issued | CITY LINE INTERIORS | 11/10/2025 |
| BIS | SP | ISSUED | ANCHOR PLUMBING CORP | 12/13/2002 |
| BIS | PL | ISSUED | P.S.I. MECHANICAL | 10/15/2002 |
| BIS | — | ISSUED | EL CONTRACTING AND PAINTING CORP | 11/14/2001 |
| BIS | OT | ISSUED | E1 CONTRACTING & PAINTING | 06/28/2001 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/18/2026 | Permit Issued | CITY LINE INTERIORS INC | Air Conditioning Systems, Heating and Air Conditioning Systems | Cooling Whisperkool MINI CELING MOUNT H.E. S-WKCMMINI-220-4 2,442 BTU · Fan Coil Indoor ×4 Heat / Cool Mitsubishi Electric PFKY-P12-NLMU-E-TH 12,000 BTU · Vrf Indoor ×8 MXZ-SM36NAM-U1 36,000 BTU · Condensing Unit ×4 PKFY-P06-NBMU-E 6,000 BTU · Vrf Indoor ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/20/2025 | Permit Issued | NYCO ELECTRIC CORP | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/28/2026 | Permit Issued | CITY LINE INTERIORS INC | Steel, Concrete |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/02/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 07/23/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/11/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/01/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/10/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/08/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/18/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/05/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 07/08/2024 | Pass-Final PL - Underground | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/22/2026 | Fire-Resistance Rated Construction | Eric Daniels | progress |
| 04/22/2026 | Final | Eric Daniels | progress |
| 04/22/2026 | Lighting in dwelling units | Eric Daniels | energy_progress |
| 04/22/2026 | Insulation placement and R values | — | energy_progress |
| 04/22/2026 | Air barrier - visual inspection | — | energy_progress |
| 04/22/2026 | Fenestration air leakage | — | energy_progress |
| 04/22/2026 | Interior lighting power | Eric Daniels | energy_progress |
| 04/22/2026 | Lighting controls | Eric Daniels | energy_progress |
| 04/22/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 04/22/2026 | Fenestration areas | — | energy_progress |
| 04/22/2026 | Masonry | Eric Daniels | special |
| 04/22/2026 | Excavations - Sheeting, Shoring, and Bracing | — | special |
| 04/22/2026 | Fire-Resistant Penetrations and Joints | Eric Daniels | special |
| 03/12/2026 | Structural Steel - Details | HENLIA CHEN | special |
| 03/12/2026 | Structural Steel - Welding | HENLIA CHEN | special |
| 03/12/2026 | Structural Steel - High Strength Bolting | HENLIA CHEN | special |
| 03/12/2026 | Structural Stability – Alterations of existing buildings | HENLIA CHEN | special |
| 03/12/2026 | Post-installed Anchors | HENLIA CHEN | special |
| 03/12/2026 | Concrete - Cast-In-Place | HENLIA CHEN | special |
| 03/12/2026 | Final | HENLIA CHEN | progress |
| 03/12/2026 | Structural Wood Frame | HENLIA CHEN | progress |
| 02/16/2026 | Fenestration areas | — | energy_progress |
| 02/16/2026 | Fenestration air leakage | — | energy_progress |
| 02/16/2026 | Insulation placement and R values | — | energy_progress |
| 02/16/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |