← Back
One story - permanent living quarter
348 BRYSON AVENUE
STATEN ISLAND · Westerleigh-Castleton Corners · BIN 5013115
💬 Discuss this project
1955Year Built
1.67Stories
A2Building Class
R3XZoning
1,406 sfGross Floor Area
1Units
One story - permanent living quarter · 8,000 sf lot · 0.18 FAR built · Flood zone X
Locations of Work
Structural
Site & exterior1 filing · 5 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHARLES A. MAGRINO, AIA110/08/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A.D. ALPHA CONSTRUCTION CGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ISLAND ENGINEERING ASSOCI264110/08/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
11/17/2025
Signed off — Alteration
CREATE NEW COVERED EXTERIOR CELLAR ENTRANCE
S01291052-I1
10/28/2025
Permit issued — Foundation
S01291052-I1-GC-CX
10/08/2025
Filed — Alteration
CREATE NEW COVERED EXTERIOR CELLAR ENTRANCE
S01291052-I1
09/22/2025
Special inspection requirement — Concrete - Cast-In-Place
WILLIAM DURDEN, P.E.
09/22/2025
Special inspection requirement — Subgrade Inspections
WILLIAM DURDEN, P.E.
09/22/2025
Special inspection requirement — Final
WILLIAM DURDEN, P.E.
09/22/2025
Special inspection requirement — Footing and Foundation
WILLIAM DURDEN, P.E.
09/22/2025
Special inspection requirement — Structural Wood Frame
WILLIAM DURDEN, P.E.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationSigned-offA.D. ALPHA CONSTRUCTION C10/28/2025
BISOTRE-ISSUEDARE NEW YORK INC05/15/2014
BISPLISSUEDLIBERTY EAST PLUMBING&HEATING09/07/2000
BIS—ISSUEDN/A04/28/2000
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/22/2025Concrete - Cast-In-PlaceWILLIAM DURDEN, P.E.special
09/22/2025Subgrade InspectionsWILLIAM DURDEN, P.E.special
09/22/2025FinalWILLIAM DURDEN, P.E.progress
09/22/2025Footing and FoundationWILLIAM DURDEN, P.E.progress
09/22/2025Structural Wood FrameWILLIAM DURDEN, P.E.progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026S01291052-I1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
05/15/2014540029351Open ↗
12/03/2013540029351Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/22/2013540029351Open ↗
▸Seals & Professional Certifications5
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION1
11/22/2013540029351Open ↗
▸BISApplicant / Owner Signature1
11/22/2013540029351Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026S01291052-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026S01291052-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026S01291052-I1Open ↗
▸Environmental & Asbestos2
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
12/03/2013540029351Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026S01291052-I1Open ↗
▸Energy Compliance5
▸BISTR8: Energy Code Progress Inspections1
11/22/2013540029351Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
02/23/2015540029351Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
02/23/2015540029351Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/23/2015540029351Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION (PTA4)1
11/22/2013540029351Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/23/2015540029351Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
11/22/2013540029351Open ↗
11/22/2013540029351Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/23/2015540029351Open ↗
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
02/23/2015540029351Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/23/2015540029351Open ↗
11/22/2013540029351Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
02/23/2015540029351Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/22/2013540029351Open ↗