← Back
Walk-up apt, over six families with stores
3488 WEBSTER AVENUE
BRONX · Norwood · BIN 2092541
💬 Discuss this project
1912Year Built
4Stories
C7Building Class
C4-4Zoning
12,075 sfGross Floor Area
19Units
Rent Stabilized34 Open Violations ▸
Walk-up apt, over six families with stores · Owner of record: AMERICAN PEN CORP · 7,855 sf lot · 1.54 FAR built · Flood zone X
Locations of Work
Mechanical
Roof2p · 1 filing · 5 docs
Floor 12p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PEN CORP AMERICAN103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHRAF CORP105/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERIOR FIRE CONTROL103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MACINTOSH ELECTRIC CORPElectrical103/22/2026
SUPERIOR FIRE CONTROL INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASHRAF CORPORATION1973105/23/2021
Building Lifecycle
All (64)Filed (1)Permit Issued (1)Violation (60)Special Inspection (2)
08/06/2026
Violation issued (HPD, open)
C
04/29/2026
Violation issued (HPD, closed)
B
04/29/2026
Violation issued (HPD, closed)
B
04/29/2026
Violation issued (HPD, open)
A
04/29/2026
Violation issued (HPD, closed)
B
04/29/2026
Violation issued (HPD, closed)
B
04/29/2026
Violation issued (HPD, open)
A
04/29/2026
Violation issued (HPD, closed)
C
04/29/2026
Violation issued (HPD, open)
C
12/09/2025
Violation issued (HPD, closed)
A
12/09/2025
Violation issued (HPD, open)
C
09/30/2025
Violation issued (HPD, closed)
C
09/30/2025
Violation issued (HPD, closed)
B
11/06/2024
Violation issued (HPD, closed)
A
11/06/2024
Violation issued (HPD, closed)
B
11/06/2024
Violation issued (HPD, closed)
A
11/06/2024
Violation issued (HPD, closed)
A
10/24/2024
Violation issued (HPD, closed)
A
10/24/2024
Violation issued (HPD, closed)
A
10/24/2024
Violation issued (HPD, closed)
B
10/24/2024
Violation issued (HPD, closed)
C
10/24/2024
Violation issued (HPD, closed)
A
10/23/2024
Violation issued (HPD, closed)
B
07/08/2024
Violation issued (HPD, closed)
B
07/08/2024
Violation issued (HPD, closed)
B
07/08/2024
Violation issued (HPD, closed)
C
07/08/2024
Violation issued (HPD, closed)
C
05/01/2024
Violation issued (HPD, open)
C
05/01/2024
Violation issued (HPD, closed)
C
05/01/2024
Violation issued (HPD, closed)
A
05/01/2024
Violation issued (HPD, closed)
C
10/10/2023
Violation issued (HPD, closed)
C
10/10/2023
Violation issued (HPD, closed)
B
10/10/2023
Violation issued (HPD, closed)
A
10/10/2023
Violation issued (HPD, closed)
B
10/10/2023
Violation issued (HPD, closed)
C
10/10/2023
Violation issued (HPD, closed)
C
10/10/2023
Violation issued (HPD, closed)
B
10/03/2023
Violation issued (HPD, closed)
B
10/03/2023
Violation issued (HPD, closed)
A
10/03/2023
Violation issued (HPD, closed)
B
01/13/2023
Violation issued (HPD, closed)
C
01/13/2023
Violation issued (HPD, closed)
C
01/13/2023
Violation issued (HPD, closed)
C
12/15/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/24/2022
Violation issued (HPD, closed)
A
08/24/2022
Violation issued (HPD, closed)
B
08/24/2022
Violation issued (HPD, closed)
C
04/27/2022
Violation issued (HPD, closed)
B
04/27/2022
Violation issued (HPD, closed)
B
04/27/2022
Violation issued (HPD, closed)
B
04/27/2022
Violation issued (HPD, closed)
B
04/27/2022
Violation issued (HPD, closed)
A
04/27/2022
Violation issued (HPD, closed)
A
04/27/2022
Violation issued (HPD, closed)
B
04/27/2022
Violation issued (HPD, closed)
A
04/27/2022
Violation issued (HPD, closed)
A
04/20/2022
Violation issued (HPD, closed)
B
04/20/2022
Violation issued (HPD, closed)
B
04/20/2022
Violation issued (HPD, closed)
A
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSUPERIOR FIRE CONTROL INC06/08/2021
BISPLISSUEDCAPE PLUMBING INC08/12/1992
BISOTISSUEDGOWIE PLUMBING & HEATING08/12/1992
1 project · most recent 05/23/2021
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/23/2021Permit IssuedSUPERIOR FIRE CONTROL INCVentilation Systems
Ventilation
Pen Vent USBI18DD 1,700 CFM · Kitchen Exhaust ×1
1 project · most recent 11/21/2023
General Wiring
FiledStatusContractorScope
11/21/2023Permit IssuedMACINTOSH ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/17/2021Mechanical SystemsAKM HOQUEspecial
03/17/2021FinalJay Kaviprogress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/25/2026X00487886-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X00487886-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/27/2026X00487886-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026X00487886-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X00487886-I1Open ↗