| Owner | Filings | Most Recent |
|---|---|---|
| ADM DEVELOPERS | 33 | 07/08/2026 |
| SD DESIGN STUDIO | 6 | 07/08/2026 |
| STEEL TONE CONSTRUCTION | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 04/28/2023 | $1.8M | — | Private party → ADM DEVELOPERS LLC | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| AARON HOCKETT ARCHITECT | 4 | 05/01/2024 |
| ATOZ CONSULTING ENGINEERS, PC | 7 | 02/29/2024 |
| STRATFORD ENGINEERING | 6 | 02/06/2024 |
| JIAN ENGINEERING PLLC | 1 | 08/21/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| WILLIAM VITACCO ASSOCIATES | 32 | 03/21/2026 |
| H Z BUILDING NY | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| STEEL TONE CONSTRUCTION | General Contractor | 18 | 07/08/2026 |
| ACER CONSTRUCTION INC | General Contractor | 4 | 07/08/2026 |
| AMC PLBG, HTG & CLNG, INC | Plumbing | 2 | 07/08/2026 |
| HF GROUP PLMBG & SPNKLER | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| REGIONAL TESTING CORP. | 394 | 10 | 05/01/2024 |
| STRATFORD ENGINEERING | 997 | 4 | 02/06/2024 |
| WELLDONE INSPECTION INC. | 8628 | 3 | 08/10/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | STEEL TONE CONSTRUCTION | 04/01/2024 |
| DOB NOW | General Construction | Permit Issued | STEEL TONE CONSTRUCTION | 02/02/2024 |
| DOB NOW | Foundation | Signed-off | STEEL TONE CONSTRUCTION | 02/01/2024 |
| DOB NOW | Structural | Signed-off | STEEL TONE CONSTRUCTION | 01/25/2024 |
| DOB NOW | Plumbing | Signed-off | AMC PLBG, HTG & CLNG, INC | 12/06/2023 |
| DOB NOW | Sprinklers | Signed-off | HF GROUP PLMBG & SPNKLER | 11/28/2023 |
| DOB NOW | Plumbing | Signed-off | AMC PLBG, HTG & CLNG, INC | 11/13/2023 |
| DOB NOW | Mechanical Systems | Signed-off | STEEL TONE CONSTRUCTION | 11/03/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | ACER CONSTRUCTION INC | 10/13/2023 |
| DOB NOW | Foundation | Signed-off | STEEL TONE CONSTRUCTION | 10/05/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | ACER CONSTRUCTION INC | 08/31/2023 |
| DOB NOW | Support of Excavation | Signed-off | STEEL TONE CONSTRUCTION | 06/09/2023 |
| DOB NOW | Foundation | Signed-off | STEEL TONE CONSTRUCTION | 06/06/2023 |
| DOB NOW | General Construction | Permit Issued | STEEL TONE CONSTRUCTION | 06/06/2023 |
| DOB NOW | Construction Fence | Signed-off | STEEL TONE CONSTRUCTION | 05/30/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/01/2024 | Permit Issued | STEEL TONE CONSTRUCTION | Air Conditioning Systems, Associated Ducts and Piping, Ventilation Systems | Cooling Mitsubishi Electric TPVFYP024AM141A 24,000 BTU · Vrf Indoor ×3 MXZ-SM36NAMHZ 36,000 BTU · Condensing Unit ×2 MXZ-SM60NAM 60,000 BTU · Condensing Unit ×2 TPVFYP012AM141A 12,000 BTU · Vrf Indoor ×2 TPVFYP018AM141A 18,000 BTU · Vrf Indoor ×2 TPKFYP012LM140A 12,000 BTU · Vrf Indoor ×1 TPVFYP012MMA144A 12,000 BTU · Vrf Indoor ×1 TPVPY030AM141A 30,000 BTU · Vrf Indoor ×1 Ventilation Greenheck G-070-VG 200 CFM · Exhaust Fan ×1 G-080-VG 225 CFM · Exhaust Fan ×1 G-090-VG 375 CFM · Exhaust Fan ×1 SP-B90 75 CFM · Exhaust Fan ×1 SQ-95-VG 360 BTU · Exhaust Fan ×1 Ducts & Piping N/A n/a Ductwork ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/01/2024 | Signed-off | AMC PLBG, HTG & CLNG, INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/08/2023 | Cancelled | J Y ELECTRIC INC | 5 meters, 5 new_meters |
| 09/28/2023 | Complete | J Y ELECTRIC INC | General Wiring |
| 07/26/2023 | Complete | J Y ELECTRIC INC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/01/2024 | Permit Issued | STEEL TONE CONSTRUCTION | Steel, Concrete, Masonry |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/01/2024 | Permit Issued | STEEL TONE CONSTRUCTION | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/29/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 02/10/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/21/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/25/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/15/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/04/2024 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 03/08/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 03/06/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 02/26/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/01/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/12/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/02/2024 | Structural Stability – Alterations of existing buildings | Paul Raymond | special |
| 05/02/2024 | Insulation placement and R values | Paul Raymond | energy_progress |
| 05/02/2024 | Fenestration air leakage | Paul Raymond | energy_progress |
| 05/02/2024 | Fenestration areas | Paul Raymond | energy_progress |
| 05/02/2024 | Fenestration and door U-factor and product ratings | Paul Raymond | energy_progress |
| 05/02/2024 | Protection of exposed foundation insulation | Paul Raymond | energy_progress |
| 05/02/2024 | Air barrier continuity plan testing | Paul Raymond | energy_progress |
| 05/02/2024 | Air barrier - visual inspection | Paul Raymond | energy_progress |
| 05/02/2024 | Fire-Resistance Rated Construction | Paul Raymond | progress |
| 05/02/2024 | Exterior Insulation and Finish Systems (EIFS) | Paul Raymond | special |
| 05/02/2024 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 04/30/2024 | Fire-Resistance Rated Construction | Paul Raymond | progress |
| 04/30/2024 | Air barrier continuity plan testing | Paul Raymond | energy_progress |
| 04/30/2024 | Air barrier - visual inspection | Paul Raymond | energy_progress |
| 04/30/2024 | Fenestration areas | Paul Raymond | energy_progress |
| 04/30/2024 | Fenestration air leakage | Paul Raymond | energy_progress |
| 04/30/2024 | Protection of exposed foundation insulation | Paul Raymond | energy_progress |
| 04/30/2024 | Insulation placement and R values | Paul Raymond | energy_progress |
| 04/30/2024 | Fenestration and door U-factor and product ratings | Paul Raymond | energy_progress |
| 04/30/2024 | Exterior Insulation and Finish Systems (EIFS) | Paul Raymond | special |
| 04/30/2024 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 04/30/2024 | Structural Stability – Alterations of existing buildings | Paul Raymond | special |
| 03/07/2024 | Sprinkler Systems | Paul Raymond | special |
| 03/01/2024 | HVAC-R and service water heating system controls | Paul Raymond | energy_progress |
| 03/01/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Paul Raymond | special |