← Back
Two family converted from one family
349 5 STREET
BROOKLYN · BIN 3021246
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6BZoning
2,450 sfGross Floor Area
2Units
Two family converted from one family · 2,000 sf lot · 1.23 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Roof1p · 1 filing · 20 docs
Cellar1p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/11/2022$1.9M—Private party → Private party$755/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PETER CHO ARCHITECTS, PLLC501/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CUTTING EDGE CONSTRUCTIONGeneral Contractor107/08/2026
FLUSHING PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781501/08/2024
Building Lifecycle
All (40)Filed (5)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (27)
02/23/2024
Signed off — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-I1
02/06/2024
Signed off — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-S1
01/19/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/09/2024
Special inspection requirement — Fenestration areas
PETER CHO
01/09/2024
Special inspection requirement — HVAC-R and service water heating equipment
PETER CHO
01/09/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
PETER CHO
01/09/2024
Special inspection requirement — Mechanical Systems
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Structural Cold-Formed Steel
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Heating Systems
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Concrete - Cast-In-Place
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Structural Steel - Details
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Masonry
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Structural Steel - High Strength Bolting
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Construction Operations Influencing Adjacent Structures
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Post-installed Anchors
CHRISTIAN LOZADA
01/09/2024
Special inspection requirement — Energy Code Compliance Inspections
PETER CHO
01/09/2024
Special inspection requirement — Fire-Resistance Rated Construction
PETER CHO
01/09/2024
Special inspection requirement — Final
PETER CHO
01/09/2024
Special inspection requirement — HVAC-R and service water heating system controls
PETER CHO
01/09/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PETER CHO
01/09/2024
Special inspection requirement — Interior lighting power
PETER CHO
01/09/2024
Special inspection requirement — Duct leakage testing, insulation and design
PETER CHO
01/09/2024
Special inspection requirement — Ventilation and air distribution system
PETER CHO
01/09/2024
Special inspection requirement — Fenestration air leakage
PETER CHO
01/09/2024
Special inspection requirement — Maintenance information
PETER CHO
01/09/2024
Special inspection requirement — Air barrier - visual inspection
PETER CHO
01/08/2024
Filed — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-P2
01/08/2024
Filed — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-P3
01/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
08/08/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/03/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/28/2023
Filed — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-P1
07/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
06/08/2023
Permit issued — Plumbing
B08051477-S1-PL
02/08/2023
Permit issued — Mechanical Systems
B08051477-I1-GC-CX
01/18/2023
Filed — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-S1
01/09/2023
Filed — Alteration
INTERIOR RENOV. OF THE EXIST. 3-STORY & CELLAR, ONE-FAMILY BUILDING. WORK CONSIST OF NEW PARTITION, DOORS AND WINDOWS. INSTALL A METAL DECK AT REAR. INSTALL DUCTLESS MINI-SPLIT UNIT. PL-FILED AS SUBSEQUENT. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08051477-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFLUSHING PLUMBING CORP06/08/2023
DOB NOWMechanical SystemsSigned-offCUTTING EDGE CONSTRUCTION02/08/2023
1 project · most recent 05/16/2023
General Wiring
FiledStatusContractorScope
05/16/2023Permit IssuedA.C. MORGAN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
01/19/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/08/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/03/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
01/09/2024Fenestration areasPETER CHOenergy_progress
01/09/2024HVAC-R and service water heating equipmentPETER CHOenergy_progress
01/09/2024Fenestration and door U-factor and product ratingsPETER CHOenergy_progress
01/09/2024Mechanical SystemsCHRISTIAN LOZADAspecial
01/09/2024Structural Cold-Formed SteelCHRISTIAN LOZADAspecial
01/09/2024Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
01/09/2024Heating SystemsCHRISTIAN LOZADAspecial
01/09/2024Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
01/09/2024Concrete - Cast-In-PlaceCHRISTIAN LOZADAspecial
01/09/2024Structural Steel - DetailsCHRISTIAN LOZADAspecial
01/09/2024MasonryCHRISTIAN LOZADAspecial
01/09/2024Structural Steel - High Strength BoltingCHRISTIAN LOZADAspecial
01/09/2024Construction Operations Influencing Adjacent StructuresCHRISTIAN LOZADAspecial
01/09/2024Post-installed AnchorsCHRISTIAN LOZADAspecial
01/09/2024Energy Code Compliance InspectionsPETER CHOprogress
01/09/2024Fire-Resistance Rated ConstructionPETER CHOprogress
01/09/2024FinalPETER CHOprogress
01/09/2024HVAC-R and service water heating system controlsPETER CHOenergy_progress
01/09/2024HVAC-R and service water piping design and insulationPETER CHOenergy_progress
01/09/2024Interior lighting powerPETER CHOenergy_progress
01/09/2024Duct leakage testing, insulation and designPETER CHOenergy_progress
01/09/2024Ventilation and air distribution systemPETER CHOenergy_progress
01/09/2024Fenestration air leakagePETER CHOenergy_progress
01/09/2024Maintenance informationPETER CHOenergy_progress
01/09/2024Air barrier - visual inspectionPETER CHOenergy_progress
Latest 25 of 27.
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/27/2026B08051477-P2Request digital key ↗
08/27/2026B08051477-P1Request digital key ↗
08/27/2026B08051477-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/27/2026B08051477-P2Open ↗
08/27/2026B08051477-P1Open ↗
08/27/2026B08051477-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026B08051477-I1Open ↗
09/01/2026B08051477-P2Open ↗
08/25/2026B08051477-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026B08051477-I1Open ↗
09/02/2026B08051477-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/27/2026B08051477-P3Open ↗
08/27/2026B08051477-P1Open ↗
08/27/2026B08051477-S1Open ↗
Showing 3 of 5 on file for this type