← Back
BuildNYC
Two stories - detached, small or mid-size
349 WHITMAN DRIVE
BROOKLYN · BIN 3242984
💬 Discuss this project
1960Year Built
2Stories
A1Building Class
R2Zoning
2,292 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 4,200 sf lot · 0.55 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralElectricalPlumbingEquipmentCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
AtticUnder Construction43p · 1 filing · 20 docs
Floor 3Under Construction37p · 1 filing · 20 docs
Floor 2Construction fence installationUnder Construction45p · 2 filings · 20 docs
Floor 1Construction fence installationUnder Construction44p · 2 filings · 20 docs
CellarConstruction fence installationUnder Construction1 filing · 4 docs
Sub-BasementConstruction fence installationUnder Construction1 filing · 4 docs
Site & exteriorConstruction fence installationUnder Construction13p · 3 filings · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/29/2022$995K—Private party → Private party$434/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MGM Creations Architecture803/03/2026
Ashraf108/29/2025
Arquitectura Varela103/28/2025
Robert Siqeca PE212/19/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A2ZCM1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Dimex GroupGeneral Contractor907/08/2026
Dimex GroupScaffold407/08/2026
Professional LineScaffold309/23/2026
City PlumbingPlumbing207/08/2026
T.G. New York ConstructorScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Steel Core Engineering PL1098309/09/2024
Structural Engineering5699212/19/2023
Building Lifecycle
All (105)Filed (12)Permit Issued (17)Violation (3)Inspection (3)Objection (40)Special Inspection (30)
09/22/2026
Permit issued — Protection and Mechanical Methods
B01279159-I1-PMM
05/14/2026
Permit issued — Plumbing
B00855354-S3-PL
05/13/2026
Permit issued — General Construction
B00855354-I1-GC
05/07/2026
Permit issued — Construction Fence
B00809597-I1-FN
05/07/2026
Permit issued — General Construction
B00809597-S1-GC
03/31/2026
Objection resolved — Addressed
03/31/2026
Objection resolved — Addressed
03/31/2026
Objection resolved — Addressed
03/30/2026
Objection raised — Structural
03/30/2026
Objection raised — Structural
03/30/2026
Objection raised — Structural
03/03/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED MECHANICAL WORK @ OSP, 001 THRU 003 & ATTIC. INSTALLATION OF NEW ELECTRICAL INTERIOR AIR HANDLING UNITS AND ELECTRICAL EXTERIOR CONDENSERS AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B00855354-P4
02/17/2026
Special inspection requirement — Energy Code Compliance Inspections
GABRIEL GINGISHVILI
02/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
GABRIEL GINGISHVILI
02/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GABRIEL GINGISHVILI
02/17/2026
Special inspection requirement — Maintenance information
GABRIEL GINGISHVILI
02/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
GABRIEL GINGISHVILI
02/17/2026
Special inspection requirement — Permanent certificate
GABRIEL GINGISHVILI
10/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/06/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/19/2025
Permit issued — Structural
B00855354-S2-ST
09/02/2025
Permit issued — Protection and Mechanical Methods
B01279159-I1-PMM
08/29/2025
Filed — Alteration
B01279159-I1
08/22/2025
Violation issued (ECB, closed)
Unknown
08/22/2025
Violation issued (ECB, closed)
Construction
07/25/2025
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/03/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED MECHANICAL WORK @ OSP, 001 THRU 003 & ATTIC. INSTALLATION OF NEW ELECTRICAL INTERIOR AIR HANDLING UNITS AND ELECTRICAL EXTERIOR CONDENSERS AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B00855354-P2
06/11/2025
Permit issued — Plumbing
B00855354-S3-PL
05/16/2025
Permit issued — General Construction
B00855354-I1-GC
04/08/2025
Permit issued — General Construction
B00809597-S1-GC
04/07/2025
Permit issued — Construction Fence
B00809597-I1-FN
03/28/2025
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01201222-I1
03/28/2025
Permit issued — Supported Scaffold
B01201222-I1-SF
10/18/2024
Special inspection requirement — Lowest Floor Elevation
Alexander Sheyman
10/18/2024
Special inspection requirement — Protection of exposed foundation insulation
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Air barrier — testing
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Air barrier - visual inspection
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Fenestration air leakage
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Insulation placement and R values
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Maintenance information
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Fenestration areas
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Permanent certificate
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Electric vehicle service equipment requirements
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Interior lighting power
GABRIEL GINGISHVILI
10/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Alexander Sheyman
10/18/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Alexander Sheyman
10/18/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
SAMER ABOU-GHAIDA
10/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
10/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
Alexander Sheyman
10/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Alexander Sheyman
10/17/2024
Objection resolved — Addressed
10/16/2024
Objection raised — Other
10/16/2024
Objection resolved — Addressed
10/16/2024
Objection raised — Other
10/15/2024
Objection resolved — Addressed
10/08/2024
Objection resolved — Addressed
10/08/2024
Objection resolved — Addressed
10/01/2024
Objection resolved — Addressed
10/01/2024
Objection resolved — Addressed
Latest 60 of 105 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWProtection and Mechanical MethodsPermit IssuedProfessional Line09/22/2026
DOB NOWPlumbingPermit IssuedCity Plumbing05/14/2026
DOB NOWGeneral ConstructionPermit IssuedDimex Group05/13/2026
DOB NOWConstruction FencePermit IssuedDimex Group05/07/2026
DOB NOWGeneral ConstructionPermit IssuedDimex Group05/07/2026
DOB NOWStructuralSigned-offDimex Group09/19/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedProfessional Line09/02/2025
DOB NOWPlumbingPermit IssuedCity Plumbing06/11/2025
DOB NOWGeneral ConstructionPermit IssuedDimex Group05/16/2025
DOB NOWGeneral ConstructionPermit IssuedDimex Group04/08/2025
DOB NOWConstruction FencePermit IssuedDimex Group04/07/2025
DOB NOWSupported ScaffoldPermit IssuedProfessional Line03/28/2025
DOB NOWGeneral ConstructionPermit IssuedDimex Group09/16/2024
DOB NOWGeneral ConstructionPermit IssuedDimex Group05/07/2024
DOB NOWGeneral ConstructionPermit IssuedDimex Group04/11/2024
DOB NOWConstruction FencePermit IssuedDimex Group04/02/2024
DOB NOWConstruction FencePermit IssuedJ.gold Construction Cons02/22/2023
1 project · most recent 03/03/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/03/2026Permit IssuedDimex GroupHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric SUZ-KA18NAH2 18,000 BTU · Heat Pump Outdoor ×4
SUZ-KA24NAH2 24,000 BTU · Heat Pump Outdoor ×4
SUZ-KA36NAH2 36,000 BTU · Heat Pump Outdoor ×4
1 project · most recent 03/03/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/03/2026Permit IssuedCity PlumbingGas, Storm, Water/Sanitary
2 projects · most recent 10/08/2025
General Wiring
FiledStatusContractorScope
10/08/2025Permit IssuedKings Electric CoGeneral Wiring
04/15/2024Permit IssuedKings Electric Co1 meters, 1 new_meters
1 project · most recent 03/03/2026
Steel
FiledStatusContractorScope
03/03/2026Permit IssuedCity PlumbingSteel
2 projects · most recent 03/28/2025
Scaffold Fence
FiledStatusContractorScope
03/28/2025Permit IssuedProfessional LineScaffold
01/11/2023Permit IssuedDimex GroupFence
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/06/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/25/2025Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
02/17/2026Energy Code Compliance InspectionsGABRIEL GINGISHVILIprogress
02/17/2026HVAC-R and service water heating system controlsGABRIEL GINGISHVILIenergy_progress
02/17/2026HVAC-R and service water piping design and insulationGABRIEL GINGISHVILIenergy_progress
02/17/2026Maintenance informationGABRIEL GINGISHVILIenergy_progress
02/17/2026HVAC-R and service water heating equipmentGABRIEL GINGISHVILIenergy_progress
02/17/2026Permanent certificateGABRIEL GINGISHVILIenergy_progress
10/18/2024Lowest Floor ElevationAlexander Sheymanprogress
10/18/2024Protection of exposed foundation insulationGABRIEL GINGISHVILIenergy_progress
10/18/2024Air barrier — testing GABRIEL GINGISHVILIenergy_progress
10/18/2024Air barrier - visual inspectionGABRIEL GINGISHVILIenergy_progress
10/18/2024Fenestration air leakageGABRIEL GINGISHVILIenergy_progress
10/18/2024Fenestration and door U-factor and product ratingsGABRIEL GINGISHVILIenergy_progress
10/18/2024Insulation placement and R valuesGABRIEL GINGISHVILIenergy_progress
10/18/2024Maintenance informationGABRIEL GINGISHVILIenergy_progress
10/18/2024Fenestration areasGABRIEL GINGISHVILIenergy_progress
10/18/2024Permanent certificateGABRIEL GINGISHVILIenergy_progress
10/18/2024Electric vehicle service equipment requirementsGABRIEL GINGISHVILIenergy_progress
10/18/2024Interior lighting powerGABRIEL GINGISHVILIenergy_progress
10/18/2024Structural Stability – Alterations of existing buildingsAlexander Sheymanspecial
10/18/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Alexander Sheymanspecial
10/18/2024Subsurface Investigations (Borings/Test Pits)SAMER ABOU-GHAIDAspecial
10/18/2024Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
10/18/2024Fire-Resistance Rated ConstructionAlexander Sheymanprogress
10/18/2024Energy Code Compliance InspectionsAlexander Sheymanprogress
09/05/2024Energy Code Compliance InspectionsAlexander Sheymanprogress
Latest 25 of 59.
▾Documents — 97 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/22/2026B01201222-I1Request digital key ↗
08/21/2026B00855354-P2Request digital key ↗
08/21/2026B00855354-S4Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
02/21/2024340908931Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
02/21/2024340908931Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/21/2026B00855354-I1Open ↗
08/13/2026B00855354-P1Open ↗
▸Seals & Professional Certifications53
▸DOB NOWProgress Inspector Seal & Signature28
10/02/2026B00855354-P1Open ↗
10/02/2026B00855354-P1Open ↗
10/02/2026B00855354-P1Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/28/2026B00809597-I1Open ↗
08/28/2026B00809597-S1Open ↗
08/21/2026B00855354-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
10/02/2026B00855354-P1Open ↗
10/02/2026B00855354-P1Open ↗
10/02/2026B00855354-P1Open ↗
Showing 3 of 11 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
02/21/2024340908931Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/21/2024340908931Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE SUPPORTING DOCUMENT1
03/20/2024340908931Open ↗
▸BISBPP: STREET TREES SITE PLAN1
02/21/2024340908931Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/21/2026B00855354-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/21/2026B00855354-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/21/2026B00855354-P2Open ↗
08/21/2026B00855354-S4Open ↗
08/21/2026B00855354-S3Open ↗
Showing 3 of 8 on file for this type
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT3
08/21/2026B00855354-I1Open ↗
08/13/2026B00855354-P1Open ↗
08/13/2026B00855354-S1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/21/2026B00855354-I1Open ↗
08/13/2026B00855354-S1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B00855354-S1Open ↗
▸Filing & Intake Forms3
▸BISEFILING JOB APPLICATION COVER SHEET1
02/21/2024340908931Open ↗
▸BISADDITIONAL INFORMATION1
07/24/2024340908931Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
02/21/2024340908931Open ↗
▸Other Documents7
▸DOB NOWSite Survey: Initial2
08/21/2026B00855354-I1Open ↗
08/13/2026B00855354-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/21/2026B00855354-I1Open ↗
08/13/2026B00855354-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/21/2026B00855354-I1Open ↗
08/15/2026B00855354-P1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
03/20/2024340908931Open ↗