← Back
Elevator apt, semi-fireproof without stores
35-07 147 STREET
QUEENS · BIN 4113223
💬 Discuss this project
1931Year Built
6Stories
D1Building Class
R7-1Zoning
60,125 sfGross Floor Area
54Units
LL97 CoveredRent Stabilized60 Open Violations 54 unresolved · 6 paperwork only ▸
Elevator apt, semi-fireproof without stores · 14,200 sf lot · 4.23 FAR built · Flood zone X
Locations of Work
Architecture
Cellar2p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
S J 147 PROPERTY MANAGEMENT1703/22/2026
147 REALTY CO.,103/22/2026
S & J ST PROPERTY MGMT103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JEON CONSULTING506/11/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SMILE & SMILE GC INCGeneral Contractor603/21/2026
I DO PLUMBING & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JEON CONSULTING5119506/11/2024
Building Lifecycle
All (84)Filed (5)Permit Issued (2)Signed Off (3)Violation (60)Inspection (4)Objection (2)Special Inspection (8)
05/07/2026
Violation issued (HPD, closed)
A
01/27/2025
Violation issued (HPD, closed)
C
01/27/2025
Violation issued (HPD, closed)
C
01/27/2025
Violation issued (HPD, open)
C
01/27/2025
Violation issued (HPD, closed)
C
01/27/2025
Violation issued (HPD, closed)
C
01/27/2025
Violation issued (HPD, open)
A
01/27/2025
Violation issued (HPD, open)
A
01/27/2025
Violation issued (HPD, open)
A
01/27/2025
Violation issued (HPD, open)
A
12/06/2024
Signed off — Alteration
PLUMBING FIXTURES REMOVAL THAT IS FILED UNDER DOB# 400088276 TO BE WITHDRAWN.3-W/C., 1-URINAL, 2-SINKS, 1-TUB, 2-GAS RANGE, 3-LAV, 1-WASHER, AND 1 DRYER TO BE REMOVED. TO INSTALL 1-W/C, 2-LAV, 1-WASHER, 1 ELECTRIC DRYER.
Q01016725-I1
12/06/2024
Signed off — Alteration
TO REMOVE ILLEGAL PARTITION WALLS, DOORS AND CARPORT CANOPY. THE VIOLATIONS # 34154120H 35226307Y 39081668K 35226307Y WILL BE REMOVED IN THIS APPLICATION.
Q00863585-I1
12/06/2024
Signed off — Alteration
TO REMOVE STAIRS & WALLS FILED AND PARTIALLY CONSTRUCTED UNDER DOB# 400088276, AND INSTALL NEW 2 HOUR FIRE-RATED EXIT PASSAGEWAY WALLS TO ENCLOSE ADDITIONAL EXIT ON CELLAR.
Q00871702-I1
11/22/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/20/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/20/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/18/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/11/2024
Filed — Alteration
PLUMBING FIXTURES REMOVAL THAT IS FILED UNDER DOB# 400088276 TO BE WITHDRAWN.3-W/C., 1-URINAL, 2-SINKS, 1-TUB, 2-GAS RANGE, 3-LAV, 1-WASHER, AND 1 DRYER TO BE REMOVED. TO INSTALL 1-W/C, 2-LAV, 1-WASHER, 1 ELECTRIC DRYER.
Q01016725-P2
06/05/2024
Special inspection requirement — Tenant Protection Plan Compliance
06/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BENJAMIN JEON
04/15/2024
Violation issued (HPD, closed)
A
04/08/2024
Permit issued — Plumbing
Q01016725-I1-PL
03/15/2024
Filed — Alteration
PLUMBING FIXTURES REMOVAL THAT IS FILED UNDER DOB# 400088276 TO BE WITHDRAWN.3-W/C., 1-URINAL, 2-SINKS, 1-TUB, 2-GAS RANGE, 3-LAV, 1-WASHER, AND 1 DRYER TO BE REMOVED. TO INSTALL 1-W/C, 2-LAV, 1-WASHER, 1 ELECTRIC DRYER.
Q01016725-I1
03/14/2024
Filed — Alteration
TO REMOVE STAIRS & WALLS FILED AND PARTIALLY CONSTRUCTED UNDER DOB# 400088276, AND INSTALL NEW 2 HOUR FIRE-RATED EXIT PASSAGEWAY WALLS TO ENCLOSE ADDITIONAL EXIT ON CELLAR.
Q00871702-P1
03/07/2024
Special inspection requirement — Final
BENJAMIN JEON
03/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BENJAMIN JEON
03/07/2024
Special inspection requirement — Tenant Protection Plan Compliance
07/14/2023
Permit issued — General Construction
Q00871702-I1-GC
06/24/2023
Violation issued (HPD, open)
C
06/24/2023
Violation issued (HPD, open)
C
05/18/2023
Objection raised — Scope
05/18/2023
Objection resolved — Addressed
05/12/2023
Filed — Alteration
TO REMOVE STAIRS & WALLS FILED AND PARTIALLY CONSTRUCTED UNDER DOB# 400088276, AND INSTALL NEW 2 HOUR FIRE-RATED EXIT PASSAGEWAY WALLS TO ENCLOSE ADDITIONAL EXIT ON CELLAR.
Q00871702-I1
04/24/2023
Filed — Alteration
TO REMOVE ILLEGAL PARTITION WALLS, DOORS AND CARPORT CANOPY. THE VIOLATIONS # 34154120H 35226307Y 39081668K 35226307Y WILL BE REMOVED IN THIS APPLICATION.
Q00863585-I1
04/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BENJAMIN JEON
04/21/2023
Special inspection requirement — Tenant Protection Plan Compliance
BENJAMIN JEON
04/21/2023
Special inspection requirement — Final
BENJAMIN JEON
03/28/2023
Violation issued (HPD, closed)
A
03/17/2023
Violation issued (ECB, closed)
Construction
03/17/2023
Violation issued (ECB, closed)
Construction
03/04/2022
Violation issued (HPD, closed)
A
06/20/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/15/2021
Violation issued (HPD, closed)
A
04/15/2021
Violation issued (HPD, closed)
I
02/02/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/29/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/09/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2019
Violation issued (HPD, closed)
C
02/27/2019
Violation issued (HPD, open)
B
02/27/2019
Violation issued (HPD, open)
B
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offI DO PLUMBING & HTG INC04/08/2024
DOB NOWGeneral ConstructionSigned-offSMILE & SMILE GC INC07/14/2023
BIS—ISSUEDS & J 147 PROPERTY MGMT C02/06/2013
BISPLISSUEDMAGOR PLG.08/30/1995
BISFBISSUEDA-ONE FUEL OIL CO.04/21/1993
BISOTISSUED37-76 62ND STREET PROP.MGMT. CO.11/15/1990
BIS—ISSUEDTHE 37-76 62ND STREET PROPERTYCO10/03/1990
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/22/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/20/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/20/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/18/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
06/05/2024Tenant Protection Plan Compliance—special
06/05/2024Fire-Resistant Penetrations and JointsBENJAMIN JEONspecial
03/07/2024FinalBENJAMIN JEONprogress
03/07/2024Fire-Resistant Penetrations and JointsBENJAMIN JEONspecial
03/07/2024Tenant Protection Plan Compliance—special
04/21/2023Fire-Resistant Penetrations and JointsBENJAMIN JEONspecial
04/21/2023Tenant Protection Plan ComplianceBENJAMIN JEONspecial
04/21/2023FinalBENJAMIN JEONprogress
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026Q00863585-I1Request digital key ↗
08/24/2026Q00871702-P1Request digital key ↗
08/22/2026Q01016725-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits18
▸BISPLAN / WORK APPROVAL APPLICATION15
02/18/2025400088276Open ↗
06/14/2024400088276Open ↗
06/14/2024400088276Open ↗
Showing 3 of 15 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION3
02/18/2025400088276Open ↗
06/14/2024400088276Open ↗
11/20/2023400134261Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026Q00871702-I1Open ↗
08/13/2026Q00863585-I1Open ↗
08/13/2026Q01016725-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026Q01016725-P2Open ↗
08/23/2026Q00871702-P1Open ↗
08/22/2026Q00863585-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q00871702-P1Open ↗
08/22/2026Q00863585-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/14/2026Q00871702-I1Open ↗
08/13/2026Q00863585-I1Open ↗
08/13/2026Q00871702-P1Open ↗