| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/22/2025 | Signed-off | PRO-H DEVELOPMENT INC | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MXZ-SM36NAM 36,000 BTU · Condensing Unit ×82 MUZ-FS18NA 17,200 BTU · Condensing Unit ×12 MUZ-FS12NA 12,000 BTU · Condensing Unit ×2 MXZ-SM36NAM-U1 36,000 BTU · Condensing Unit ×40 MUZ-FS18NA-U1 17,200 BTU · Condensing Unit ×6 MUZ-FS12NA-U1 12,000 BTU · Condensing Unit ×1 Carrier 24ABB348A360 48,000 BTU · Condensing Unit ×2 24ABB360A300 60,000 BTU · Condensing Unit ×2 48FCEA06A2A5-0A0A0 5 tons · Rooftop Unit ×2 48FCEA06A2A5A0A0A0 5 tons · Rooftop Unit ×1 24ABB348 48,000 BTU · Condensing Unit ×1 24ABB360 60,000 BTU · Condensing Unit ×1 Heating Mitsubishi Electric MXZ-SM36NAM 42,000 BTU · Condensing Unit ×82 MUZ-FS18NA 19,000 BTU · Condensing Unit ×12 MUZ-FS12NA 12,300 BTU · Condensing Unit ×2 MXZ-SM36NAM-U1 42,000 BTU · Condensing Unit ×40 MUZ-FS18NA-U1 19,000 BTU · Condensing Unit ×6 MUZ-FS12NA-U1 12,300 BTU · Condensing Unit ×1 Cadet CS101T 1 kW ×16 Carrier 48FCEA06A2A5A0A0A0 110,000 BTU · Rooftop Unit ×2 48FCEA06A2A5-0A0A0 110,000 BTU · Rooftop Unit ×1 59MN7B110E21--20 110,000 BTU · Furnace ×1 59MN7B135E24--20 132,000 BTU · Furnace ×1 Stelpro AB41008HAW 1 kW · Electric Heater ×8 Ventilation Coolair RIBA20MD8363 5,600 CFM · Exhaust Fan ×6 Mitsubishi Electric LGH-F940RVX2-E 940 CFM · Erv ×3 Vortex Powerfans VTX400 220 CFM · Exhaust Fan ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/22/2025 | Signed-off | MPS PLUMBING & HEATING IN | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/22/2025 | Signed-off | MPS PLUMBING & HEATING IN | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2024 | Complete | EMP ELECTRIC CORP | General Wiring, Lighting |
| 04/25/2024 | Complete | POWER SURGE ELECTRIC, INC | — |
| 04/22/2024 | Complete | EMP ELECTRIC CORP | General Wiring, Lighting |
| 11/02/2022 | Complete | KJK ELECTRIC INC | General Wiring |
| 06/16/2022 | Complete | BOROWIDE ELECT'L CONTR'S | — |
| Owner | Filings | Most Recent |
|---|---|---|
| PRO-H DEVELOPMENT | 25 | 07/08/2026 |
| WY UNION HOLDING | 22 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| A & T ENGINEERING, P.C. | 20 | 12/01/2025 |
| CNY ENGINEERING P.C | 8 | 03/01/2024 |
| ENTHINK ENGINEERS LLC | 7 | 02/03/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| CNY ENGINEERING PC | 16 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| PRO-H DEVELOPMENT INC | General Contractor | 23 | 07/08/2026 |
| ANDAMIO SCAFFOLDING LLC | General Contractor | 8 | 07/08/2026 |
| MPS PLUMBING & HEATING INC | Plumbing | 2 | 07/08/2026 |
| MPS PLUMBING & HEATING INC | Fire Protection | 2 | 07/08/2026 |
| BOROWIDE ELECT'L CONTR'S | Electrical | 1 | 03/22/2026 |
| ROBERT LIN | Electrical | 1 | 03/21/2026 |
| POWER SURGE ELECTRIC, INC | Electrical | 1 | 03/22/2026 |
| VICTOR PENG | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| S&S CONCRETE & SOIL TESTI | 1008 | 24 | 05/22/2025 |
| ENTHINK ENGINEERS LLC | 6247 | 1 | 06/02/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | PRO-H DEVELOPMENT INC | 02/29/2024 |
| DOB NOW | Standpipe | Signed-off | MPS PLUMBING & HEATING INC | 02/05/2024 |
| DOB NOW | Curb Cut | Signed-off | PRO-H DEVELOPMENT INC | 01/30/2024 |
| DOB NOW | General Construction | Permit Issued | PRO-H DEVELOPMENT INC | 11/08/2023 |
| DOB NOW | Sprinklers | Signed-off | MPS PLUMBING & HEATING IN | 09/28/2023 |
| DOB NOW | General Construction | Permit Issued | PRO-H DEVELOPMENT INC | 08/11/2023 |
| DOB NOW | Construction Fence | Signed-off | PRO-H DEVELOPMENT INC | 08/10/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | ANDAMIO SCAFFOLDING LLC | 05/30/2023 |
| DOB NOW | Sprinklers | Signed-off | MPS PLUMBING & HEATING INC | 04/03/2023 |
| DOB NOW | Sprinklers | Signed-off | MPS PLUMBING & HEATING IN | 08/29/2022 |
| DOB NOW | General Construction | Permit Issued | PRO-H DEVELOPMENT INC | 08/24/2022 |
| DOB NOW | General Construction | Permit Issued | PRO-H DEVELOPMENT INC | 08/23/2022 |
| DOB NOW | Construction Fence | Signed-off | PRO-H DEVELOPMENT INC | 08/22/2022 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | ANDAMIO SCAFFOLDING LLC | 06/02/2022 |
| DOB NOW | Sidewalk Shed | Signed-off | ANDAMIO SCAFFOLDING LLC | 06/02/2022 |
| DOB NOW | Supported Scaffold | Signed-off | ANDAMIO SCAFFOLDING LLC | 06/02/2022 |
| DOB NOW | Construction Fence | Signed-off | PRO-H DEVELOPMENT INC | 06/01/2022 |
| DOB NOW | General Construction | Permit Issued | PRO-H DEVELOPMENT INC | 05/27/2022 |
| DOB NOW | Foundation | Signed-off | PRO-H DEVELOPMENT INC | 05/23/2022 |
| DOB NOW | Support of Excavation | Signed-off | PRO-H DEVELOPMENT INC | 05/23/2022 |
| DOB NOW | Foundation | Signed-off | PRO-H DEVELOPMENT INC | 05/23/2022 |
| DOB NOW | Structural | Signed-off | PRO-H DEVELOPMENT INC | 05/20/2022 |
| DOB NOW | Support of Excavation | Signed-off | PRO-H DEVELOPMENT INC | 05/17/2022 |
| DOB NOW | Foundation | Signed-off | PRO-H DEVELOPMENT INC | 05/10/2022 |
| BIS | OT | ISSUED | ACCORD POWER INC | 04/23/2024 |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/06/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/09/2025 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 06/18/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/30/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/07/2024 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 02/12/2024 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 02/09/2024 | Pass-Final SD - Up to 9 Requested Floors | Pass | View ↗ |
| 02/07/2024 | Certified StandPipe-SD-Piping-Hydrostatic Test | Certified | View ↗ |
| 02/02/2024 | Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test | Certified | View ↗ |
| 02/02/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 02/02/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/31/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 01/30/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 09/28/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/09/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/19/2023 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 09/12/2022 | Pass-Final PL - Underground | Pass | View ↗ |
| 06/17/2022 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/23/2025 | Excavations - Sheeting, Shoring, and Bracing | GLEN LANGER | special |
| 05/23/2025 | Lighting in dwelling units | GLEN LANGER | energy_progress |
| 05/23/2025 | Insulation placement and R values | GLEN LANGER | energy_progress |
| 05/23/2025 | HVAC-R and service water piping design and insulation | GLEN LANGER | energy_progress |
| 05/23/2025 | Lighting controls | GLEN LANGER | energy_progress |
| 05/23/2025 | Air barrier - visual inspection | GLEN LANGER | energy_progress |
| 05/23/2025 | Fenestration and door U-factor and product ratings | GLEN LANGER | energy_progress |
| 05/23/2025 | Exterior lighting power | GLEN LANGER | energy_progress |
| 05/23/2025 | Air barrier — testing | GLEN LANGER | energy_progress |
| 05/23/2025 | Fenestration areas | GLEN LANGER | energy_progress |
| 05/23/2025 | Interior lighting power | GLEN LANGER | energy_progress |
| 05/23/2025 | Fire-Resistance Rated Construction | GLEN LANGER | progress |
| 05/23/2025 | Energy Code Compliance Inspections | GLEN LANGER | progress |
| 05/23/2025 | Wall Panels, Curtain Walls, and Veneers | GLEN LANGER | special |
| 05/23/2025 | Masonry | GLEN LANGER | special |
| 05/23/2025 | Exterior Insulation and Finish Systems (EIFS) | GLEN LANGER | special |
| 05/23/2025 | Post-installed Anchors | GLEN LANGER | special |
| 05/23/2025 | Concrete - Cast-In-Place | GLEN LANGER | special |
| 05/23/2025 | Fire-Resistant Penetrations and Joints | GLEN LANGER | special |
| 05/23/2025 | Subgrade Inspections | GLEN LANGER | special |
| 04/17/2025 | Fire-Resistant Penetrations and Joints | GLEN LANGER | special |
| 04/17/2025 | Fenestration and door U-factor and product ratings | GLEN LANGER | energy_progress |
| 04/17/2025 | Interior lighting power | GLEN LANGER | energy_progress |
| 04/17/2025 | Exterior lighting power | GLEN LANGER | energy_progress |
| 04/17/2025 | Air barrier — testing | GLEN LANGER | energy_progress |