← Back
All parking garages
35-17 42 STREET
QUEENS · BIN 4010892
💬 Discuss this project
1925Year Built
1Stories
G1Building Class
M1-5/R9-1Zoning
10,000 sfGross Floor Area
2Units
All parking garages · Owner of record: 42-08 35TH OWNER LLC · 10,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
MechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 3 docs
Floor 11Under Construction1 filing · 20 docs
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6Under Construction1 filing · 20 docs
Floor 5Under Construction1 filing · 20 docs
Floor 4Under Construction1 filing · 20 docs
Floor 3
Floor 2
Floor 1Under Construction1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HEARTFELT BUILDERS303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ELEVATED ENGINEERING NYC404/03/2026
ADROIT ENGINEERING PLLC401/30/2026
A&D ENGINEERING, PLLC412/30/2025
JFA ARCHITECTS & ENGINEERS DPC110/24/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BAC Developers Group803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
POWER DIRECT ELECTRIC INCElectrical203/22/2026
HEARTFELT TOWNHOUSE BUILDGeneral Contractor209/26/2026
MPI PLUMBING CORPPlumbing209/29/2026
M.R. ELEC'L SERVICE LLCElectrical103/22/2026
N TECH DESIGN OF AMERICAGeneral Contractor109/17/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616112/30/2025
ADROIT ENGINEERING PLLC8885108/22/2025
Building Lifecycle
All (63)Filed (13)Permit Issued (5)Objection (15)Special Inspection (30)
09/28/2026
Permit issued — Sprinklers
Q01297609-S6-EW-SD
09/25/2026
Permit issued — Plumbing
Q01297609-S5-PL
09/25/2026
Permit issued — Mechanical Systems
Q01297609-S4-MS
09/16/2026
Permit issued — Full Demolition
Q01243911-I1-FD
07/07/2026
Permit issued — Construction Fence
Q01314412-I1-FN
04/28/2026
Objection resolved — Open
04/28/2026
Objection resolved — Open
04/13/2026
Objection resolved — Addressed
04/10/2026
Objection raised — Admin
04/03/2026
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-P1
03/18/2026
Special inspection requirement — Air barrier continuity plan testing
02/13/2026
Objection resolved — Addressed
02/10/2026
Objection raised — Other
02/10/2026
Objection raised — Other
02/09/2026
Objection raised — Energy
01/30/2026
Filed — Alteration
Q01314412-P1
12/30/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S5
12/30/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S7
12/30/2025
Special inspection requirement — Standpipe Systems
12/29/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S6
12/29/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S4
12/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
12/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
12/29/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
SHAHRIAR QUAYYUM
12/29/2025
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
12/29/2025
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
12/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
12/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
12/22/2025
Objection resolved — Addressed
12/17/2025
Objection raised — Structural
12/15/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S3
11/28/2025
Objection raised — Admin
11/28/2025
Objection raised — Zoning
11/28/2025
Objection raised — Zoning
11/20/2025
Objection raised — Admin
11/19/2025
Objection raised — Zoning
11/12/2025
Filed — Alteration
Q01314412-I1
11/03/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S1
11/03/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-S2
10/27/2025
Special inspection requirement — Final
10/27/2025
Special inspection requirement — Concrete - Cast-In-Place
10/27/2025
Special inspection requirement — Construction Operations Influencing Adjacent Structures
10/27/2025
Special inspection requirement — Masonry
10/27/2025
Special inspection requirement — Post-installed Anchors
10/27/2025
Special inspection requirement — Concrete - Cast-In-Place
SHAHRIAR QUAYYUM
10/27/2025
Special inspection requirement — Construction Operations Influencing Adjacent Structures
SHAHRIAR QUAYYUM
10/27/2025
Special inspection requirement — Subgrade Inspections
SHAHRIAR QUAYYUM
10/27/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
SHAHRIAR QUAYYUM
10/27/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rui Guo
10/27/2025
Special inspection requirement — Final
SHAHRIAR QUAYYUM
10/27/2025
Special inspection requirement — Footing and Foundation
SHAHRIAR QUAYYUM
10/24/2025
Filed — New Building
TEMPORARY STANDPIPE SYSTEM FILED IN CONJUNCTION WITH NB JOB NUMBER Q01297609-I1.
Q01297609-I1
10/16/2025
Special inspection requirement — Interior lighting power
10/16/2025
Special inspection requirement — Fenestration air leakage
10/16/2025
Special inspection requirement — Insulation placement and R values
10/16/2025
Special inspection requirement — Lighting controls
10/16/2025
Special inspection requirement — Metering
10/16/2025
Special inspection requirement — Vestibules
10/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/16/2025
Special inspection requirement — Protection of exposed foundation insulation
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedMPI PLUMBING CORP09/28/2026
DOB NOWPlumbingPermit IssuedMPI PLUMBING CORP09/25/2026
DOB NOWMechanical SystemsPermit IssuedHEARTFELT TOWNHOUSE BUILD09/25/2026
DOB NOWFull DemolitionPermit IssuedN TECH DESIGN OF AMERICA09/16/2026
DOB NOWConstruction FencePermit IssuedHEARTFELT TOWNHOUSE BUILD07/07/2026
BISEQISSUEDMASKIELL & SONS, INC.07/01/2005
BISMHISSUEDMASKIELL & SONS, INC.07/01/2005
BISPLISSUEDSCHUMACHER & FARLEY P&H C07/01/2005
1 project · most recent 04/03/2026
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/03/2026Permit IssuedHEARTFELT TOWNHOUSE BUILDAir Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin RXTA48AAVJU 45,500 BTU · Vrf Outdoor ×2
RXTA24AAVJU 23,000 BTU · Vrf Outdoor ×1
RXTA36AAVJU 34,200 BTU · Vrf Outdoor ×1
Heat / Cool
Islandaire EZLA16L341E 375 CFM · Heat Pump Outdoor ×67
EZLA09L231E 375 CFM · Heat Pump Outdoor ×63
Heating
Daikin RXTA48AAVJU 47,500 BTU · Vrf Outdoor ×2
RXTA24AAVJU 25,800 BTU · Vrf Outdoor ×1
RXTA36AAVJU 37,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck SP-B50-QD 110 CFM · Exhaust Fan ×84
G-100-VG 775 CFM · Exhaust Fan ×5
G-140-VG 1,250 CFM · Exhaust Fan ×2
AX-47-160-0627 5,400 CFM · Exhaust Fan ×1
AX-47-190-0621 5,400 CFM · Exhaust Fan ×1
G-095-VG 375 CFM · Exhaust Fan ×1
SQ-90-VG 180 CFM · Exhaust Fan ×1
Panasonic FV-0511VQ1 110 CFM · Exhaust Fan ×1
1 project · most recent 04/03/2026
Sprinkler System
FiledStatusContractorScope
04/03/2026——Sprinkler System
1 project · most recent 04/03/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/03/2026Permit IssuedMPI PLUMBING CORPGas, Storm, Water/Sanitary
9 projects · most recent 08/21/2026
General Wiring
FiledStatusContractorScope
08/21/2026Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
12/16/2025Permit IssuedPOWER DIRECT ELECTRIC INC1 meters, 1 new_meters
12/16/2025Permit IssuedPOWER DIRECT ELECTRIC INC68 meters, 68 new_meters
12/16/2025Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
12/15/2025Permit IssuedPOWER DIRECT ELECTRIC INC1 meters, 1 new_meters
12/15/2025Permit IssuedPOWER DIRECT ELECTRIC INC1 meters, 1 new_meters
12/15/2025Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
12/09/2025Permit IssuedM.R. ELEC'L SERVICE LLCGeneral Wiring
12/09/2025Permit IssuedM.R. ELEC'L SERVICE LLCGeneral Wiring
1 project · most recent 04/03/2026
Concrete
FiledStatusContractorScope
04/03/2026Permit IssuedMPI PLUMBING CORPConcrete
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
03/18/2026Air barrier continuity plan testing—energy_progress
12/30/2025Standpipe Systems—special
12/29/2025HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
12/29/2025Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
12/29/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSHAHRIAR QUAYYUMspecial
12/29/2025Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
12/29/2025Maintenance informationSHAHRIAR QUAYYUMenergy_progress
12/29/2025HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
12/29/2025HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
10/27/2025Final—progress
10/27/2025Concrete - Cast-In-Place—special
10/27/2025Construction Operations Influencing Adjacent Structures—special
10/27/2025Masonry—special
10/27/2025Post-installed Anchors—special
10/27/2025Concrete - Cast-In-PlaceSHAHRIAR QUAYYUMspecial
10/27/2025Construction Operations Influencing Adjacent StructuresSHAHRIAR QUAYYUMspecial
10/27/2025Subgrade InspectionsSHAHRIAR QUAYYUMspecial
10/27/2025Subsurface Conditions – Fill Placement & In-Place DensitySHAHRIAR QUAYYUMspecial
10/27/2025Subsurface Investigations (Borings/Test Pits)Rui Guospecial
10/27/2025FinalSHAHRIAR QUAYYUMprogress
10/27/2025Footing and FoundationSHAHRIAR QUAYYUMprogress
10/16/2025Interior lighting power—energy_progress
10/16/2025Fenestration air leakage—energy_progress
10/16/2025Insulation placement and R values—energy_progress
10/16/2025Lighting controls—energy_progress
Latest 25 of 38.
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/18/2026Q01314412-I1Request digital key ↗
08/18/2026Q01314412-P1Request digital key ↗
08/17/2026Q01297609-S4Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
11/26/2025440826723Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026Q01297609-I1Open ↗
08/13/2026Q01297609-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/26/2025440826723Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01297609-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q01297609-I1Open ↗
▸Seals & Professional Certifications14
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/18/2026Q01314412-I1Open ↗
08/18/2026Q01314412-P1Open ↗
08/17/2026Q01297609-S5Open ↗
Showing 3 of 11 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/26/2025440826723Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/26/2025440826723Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/13/2026Q01297609-S1Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q01297609-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01297609-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWOER: Notice to Proceed2
08/17/2026Q01297609-S1Open ↗
08/17/2026Q01297609-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT3
08/17/2026Q01297609-S1Open ↗
08/13/2026Q01297609-S3Open ↗
08/13/2026Q01297609-P1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01297609-S3Open ↗
▸Filing & Intake Forms2
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
11/26/2025440826723Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/26/2025440826723Open ↗
▸Other Documents6
▸BISBPP - SUPPORTING DOCUMENTATION2
11/26/2025440826723Open ↗
11/26/2025440826723Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01297609-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026Q01243911-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01297609-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026Q01297609-I1Open ↗